Based on the API 610 requirement the overall vibration for overhung pump shall be less than 3 mm/s (0.12 in/s) for overall frequency and 2 mm/s (0.08 in/s) for discrete frequency. The API 610 requires out of preferred operating region the vibration level shall not be more than 30% of above-mentioned limits.