Transmission Lines | Stringing
Ғылым және технология
Stringing- Paying out
More on:
Foundation- • Transmission Lines | F...
Rock Anchor Foundation - • Transmission Lines | R...
Erection- • Transmission Lines | T...
Under Ground Cable- • UNDERGROUND CABLE | La...
OPGW- • UNDERGROUND CABLE | La...
Pile Load Test- • Pile Load Test
Scaffolding- • Scaffolding
Erection- • Transmission Lines I T...
Stringing- • Transmission Lines | S...
Conductor Sagging- • Transmission Lines | C...
Tower Testing- • Transmission Lines | T...
GIS Termination- • UNDERGROUND CABLE | GI...
Shotcrete- • Shotcrete | Gunite | S...
Monopole Erection (Suspension)- • Video
Monopole Erection (Tension)- • Monopole Erection | Te...
Cable Installation- • Underground Cable
Subscribe:
/ pritamsingharoy
Enjoy Watching!
Пікірлер: 142
Link for other Transmission Line Work Foundation- kzread.info/dash/bejne/iWl7lLawdLq5nrg.html Erection- kzread.info/dash/bejne/qKZ4pY99ltHUmNo.html Under Ground Cable- kzread.info/dash/bejne/k6ahrrl_dcyepM4.html OPGW- kzread.info/dash/bejne/k6ahrrl_dcyepM4.html Pile Load Test- kzread.info/dash/bejne/pqai1Ld7haa-d9I.html Scaffolding- kzread.info/dash/bejne/Z6uA2s6qZq2rZJM.html Erection- kzread.info/dash/bejne/dWGFys2AktvYqbQ.html Conductor Sagging- kzread.info/dash/bejne/h6ehurFwe7GonMY.html Tower Testing- kzread.info/dash/bejne/n2SA1sl-mJiwecY.html
@chanakasampathbandar
5 жыл бұрын
Hi thanks
@MotoWild86
4 жыл бұрын
hi pritam. love your videos. i'm kinda of noob in power line works :D. could you please explain to me how to determine maximum length of a pulling machine can handle based on pulling force capacity of the machine? thanks
@ibrahimmalcolm5406
2 жыл бұрын
I guess im asking the wrong place but does any of you know of a trick to log back into an instagram account..? I was stupid forgot the account password. I love any help you can offer me
@kristophernicolas5195
2 жыл бұрын
@Ibrahim Malcolm Instablaster :)
@ibrahimmalcolm5406
2 жыл бұрын
@Kristopher Nicolas I really appreciate your reply. I got to the site thru google and Im waiting for the hacking stuff atm. Takes a while so I will reply here later with my results.
Hardworking Indian brothers 👏👏🤗💕
Good & Helpful for people working in Transmission Sector
It couldn't be better explained. Thanks for sharing.
@PritamSingharoy
6 жыл бұрын
thanks for ur valuable feedback
Thanks for uploading this video. It is very helpful as it explains nearly whole process in details. It cleared all my doubts. Thank You once again🙏
@PritamSingharoy
4 жыл бұрын
You are most welcome
Asalaam aliakum. Hey everyone thank you for the video and for detailing your video with instructions so others can learn from you. You are much appreciated!! And I especially loved how you added special editing features in your video!! You are so wonderful and awesome!! It made me feel love today so thank you very much!! May Almighty God bless, protect, forgive, and continue unconditionally loving you, your families, and all your loves ones, and us all!! (Bismill Allah).. have a blessed, safe, and loving day and thank you again.. Asalaam ✌️ peace Loves you all!!
Using cut resistance gloves make much safer in cable pulling and sleeving
Good job my friend 👍
Great work
Very nice !
Though job salute to tata power
EXCELLENT VIDEO
WOW!
I'm very glad I saw this video. Thank you
@PritamSingharoy
5 жыл бұрын
Welcome
@PritamSingharoy
5 жыл бұрын
There are lots of video on Foundation, Erection, Stringing, OPGW, UG Cable. Visit my page to grab more and pls share if you liked it Foundation- kzread.info/dash/bejne/iWl7lLawdLq5nrg.html Erection- kzread.info/dash/bejne/qKZ4pY99ltHUmNo.html Under Ground Cable- kzread.info/dash/bejne/k6ahrrl_dcyepM4.html OPGW- kzread.info/dash/bejne/k6ahrrl_dcyepM4.html Pile Load Test- kzread.info/dash/bejne/pqai1Ld7haa-d9I.html Scaffolding- kzread.info/dash/bejne/Z6uA2s6qZq2rZJM.html Erection- kzread.info/dash/bejne/dWGFys2AktvYqbQ.html Stringing- kzread.info/dash/bejne/ZoCex5JwaJeekqg.html Conductor Sagging- kzread.info/dash/bejne/h6ehurFwe7GonMY.html Tower Testing- kzread.info/dash/bejne/n2SA1sl-mJiwecY.html
Great video
awesome knowledgeable vdo
good job
Awesome
Good information
good video. please share the videos of soil resisitivity measurement, TFR measurement, resistance of Midspan joint measurement.
Không tra mỡ bảo dưỡng lõi thép và mỡ tiếp xúc lõi nhôm hả
Wonderful
Thanks for your sharing 👍
keep it up
Very nice and good job informative Video. Ram Yadav An Electrical Engineer
@sharmaelectricalsservices9391
5 жыл бұрын
Ram Yadav ji I mush interested in this field please note my no 7507048097
Make sure a marking before aluminum tube lying (for both end of the conductor is equal jointing)
Hard job and keep safety
Very factual video...... Nice Keep it up... Put some more videos ......
@PritamSingharoy
5 жыл бұрын
There are lots of video on Foundation, Erection, Stringing, OPGW, UG Cable. Visit my page to grab more and pls share if you liked it Foundation- kzread.info/dash/bejne/iWl7lLawdLq5nrg.html Erection- kzread.info/dash/bejne/qKZ4pY99ltHUmNo.html Under Ground Cable- kzread.info/dash/bejne/k6ahrrl_dcyepM4.html OPGW- kzread.info/dash/bejne/k6ahrrl_dcyepM4.html Pile Load Test- kzread.info/dash/bejne/pqai1Ld7haa-d9I.html Scaffolding- kzread.info/dash/bejne/Z6uA2s6qZq2rZJM.html Erection- kzread.info/dash/bejne/dWGFys2AktvYqbQ.html Stringing- kzread.info/dash/bejne/ZoCex5JwaJeekqg.html Conductor Sagging- kzread.info/dash/bejne/h6ehurFwe7GonMY.html Tower Testing- kzread.info/dash/bejne/n2SA1sl-mJiwecY.html
អរគុណ👏
Nice video
What is the price for the hydraulic cable compressor?
Nice video But sir plz name the stand which support the cable drum
@PritamSingharoy
6 жыл бұрын
Drum Lifting Jack- Spindle is more strong than ordinary one
Thank you boss
@PritamSingharoy
4 жыл бұрын
Welcome
Nice
How heavy is the spool at 0:58 ?
Why the music?
Great
Hard job for all linemen
Good
Sem equipamentos de proteção. Cade a segurança?
Add More videos on Transmission line Towers I.e Type of Tower, Its erection etc
@PritamSingharoy
5 жыл бұрын
Sure.....
good and informative
@PritamSingharoy
6 жыл бұрын
veda akula Thanks
@TahirHussain-ih6gd
6 жыл бұрын
Any jsa available please share with me myself email tahirhse.fatima@gmail.com
@PritamSingharoy
6 жыл бұрын
e-mailed
Slute to those workers, really hard job to do
different work like the video
Proud to be an engineer
Darun bhai...
@PritamSingharoy
6 жыл бұрын
Thanks
Knowledgeable
@traplandtrinitie4955
11 ай бұрын
Ima blackman I tell you Indians are goodlinemen too
@PritamSingharoy
11 ай бұрын
Yup
I need 11kv cable jointing technician. Can you provide??
@salimshipai4720
5 жыл бұрын
ya I can send the place where u need it
How much Compression force is applied to make steel and aluminium mid span and dead end joints
@faizan28880
4 жыл бұрын
800 to 1000bar
Are not you using a metal mesh for getting the induction?
@khanbro.5813
5 жыл бұрын
What's metal mesh please explain me about this?
Where is the safety gloves :/
👍👍👍👍
Informative I think Bariq~Muhail 132kv line
@muhammadshafique8810
5 жыл бұрын
Thanks for like
@shaanshaan7790
5 жыл бұрын
220 kv
Safety First
Send me TL procedures
स्टोर कहां है सर
good work.... ye kon c company hai.... India me hai keya...?
@PritamSingharoy
5 жыл бұрын
One of the renowned company of India
Sir mujhe foundation drawing ka sara videos chahiye
Kuch chijo ko sequence Me dena chahiye
how to know that line is 33kv, 66kv, 132kv. Please help me
@PritamSingharoy
5 жыл бұрын
Hie.... The answer to ur query There are several guiding factor which determine the rating of T/L 1. Insulator- Generally each disc of Insulator comes with rating of 11kV So, Line voltage can be assumed= No. Of disc * 11*1.73 This formula hold good above 132kV Below 132kV= No. Of Insulator*11 Now a days, various different rating insulator are coming. Example- long rod Insulator In that u have to check the bundling of conductor also 2. No. Of bundle- generally twin bundling is used below 220kV. Above 220kV quad, hexa etc used
Bhai mujhe bataye opg kaya hota hai
@PritamSingharoy
6 жыл бұрын
Sumit das Watch the video on OPGW in below link. kzread.info/dash/bejne/q2qmzs5mm6rKipM.html Feel free if you have any queries afterward
The worst thing in this job is the heat of the sky🌞. The worse is only -15 ° C🌨 and frostbitten hands. 🔌👲👍⚡
@PritamSingharoy
4 жыл бұрын
Exactly
What is the size of the conductor?
@PritamSingharoy
5 жыл бұрын
In the video it is 28.11 mm
@pavankumar1078
5 жыл бұрын
Panther or zeberg
@PritamSingharoy
5 жыл бұрын
Its ACSR/AW Drake
I bet it takes years to put them up completely
@PritamSingharoy
6 жыл бұрын
MassiveKilla93xx ha ha Fortunately the video is completed within 7 days.
Hi
Location kahan ki hai sir
@PritamSingharoy
5 жыл бұрын
Saudi Arabia
Sir I am ITI electrician pass
Are not you using rolling grounding?
@PritamSingharoy
6 жыл бұрын
Justo Benjamín Ágreda Tejera Ground roller is used. It is shown in video
@Obtuso89
6 жыл бұрын
Yes Sr. I saw it. but we use other kind of ground roller, they are closer to the machines. And we use equipotential mesh under the machines too. I can see that your way to work is very diferent. Great video¡, thanks¡
@PritamSingharoy
6 жыл бұрын
Justo Benjamín Ágreda Tejera Actually it varies from region to region. Also vary with client requirement
@adakali8179
5 жыл бұрын
Which video.
Would have been better without the music and ridiculous visual effects
No gloves got my eyes
Tell your worker to use cotton gloves
Contact Mail ?
Transmission line ke tar itne thick Kyu hai.
@khanbro.5813
5 жыл бұрын
Q ki ye EHV line hai or ye moose conductor 400kv overhead transmission line me use hota hai.
@PritamSingharoy
5 жыл бұрын
Technically it depends on no. of factor. Major factor which determine the dia of conductor is current carrying capacity, however the dia is also limited by skin and proximity effect.
Eg
Way too slow, there are so many things require improvement
@PritamSingharoy
5 жыл бұрын
Feedback/recommendation on the observed deficit are highly appreciated.
Safety System much poor..
@PritamSingharoy
5 жыл бұрын
Feedback/recommendation on the observed deficit are highly appreciated.
Not safe no gloves no proper training were is your safety engineer soppose to be he should responsible for this video. Remember it's a risky working on high voltage of electric safety first before you posted in you tube just saying only cause work also on the same category but not like this no safety gloves
@PritamSingharoy
5 жыл бұрын
I understand ur concern and appreciate for putting ur valuable comments. Pls be noted that construction is under progress and the line is not energized so no high voltage gloves are require. Only general gloves can be worn to avoid any small cuts.
@manishholla
5 жыл бұрын
@@PritamSingharoy yup. Right
Great work
Good
Good