Torsional Irregularity check in ETABS as per IS 1893:2016 Excel Sheet

Torsional Irregularity check in ETABS as per IS 1893:2016 Excel Sheet
Torsional Irregularity Check
IS 1893(Part 1)2016 Table 5 Clause 7.1(i)
A building is said to be torsionally irregular, when the maximum horizontal displacementof any floor in the direction of the lateral force at one end of the floor is more than 1.5 times its minimum horizontal displacement at the far end of the same floor in that direction.