TOP 5 RUST CIRCUITS

Ойындар

My Discord
/ discord
Thanks for Watching!
Don't Forget to Subscribe and Drop a Like!
Degenerate Gamblers KZread
/ @degenerategambler9847
Rustricity Server Discord
/ discord

Пікірлер: 69

  • @legslarrysmith_
    @legslarrysmith_6 ай бұрын

    Very helpful and well explained other than a couple of verbal missay's. Thanks for sharing and keep up with the content grind, you'll reap the rewards sooner than you think once the algorithm gives you a boost in traffic. I'll sub to help you out and because you have some very worthy knowledge of the game that I love and have done for many years.

  • @TCS23
    @TCS23Сағат бұрын

    Thanks for the video, the music was competing against your voice though.

  • @robcadell29
    @robcadell293 ай бұрын

    Thank you good video also for explaining things. Awesome job

  • @marrracaharaca1013
    @marrracaharaca10136 ай бұрын

    LOVE the backround music, and the vid ofcourse

  • @s0fakingawes0me14
    @s0fakingawes0me146 ай бұрын

    Great video !! Maybe next one you can show the Nih Core in action. The switchover resets the industrial crafter to off (I put sm bat inline with input = 2) and resets any timers in use.

  • @jacobrose9606
    @jacobrose96065 ай бұрын

    Auto-Start-Stop Electrical Furnaces: Piping: Large Box -> Input Conveyor -> Furnace Chain - > Output Conveyor -> Storage Electrical (Mainline): Switch -> Input Conveyor -> Output Conveyor -> Memory Cell -> Splitter(s) - > Furnaces Electrical (Auto-Start): Input Conveyor (filter pass) -> Memory Cell (Set) Electrical (Auto-Stop): Output Conveyor (filter fail) -> Memory Cell (Reset) The switch only exists to cut power to the circuit and can be skipped if preferred. Remember that you need to manually Turn On each furnace once per server reset.

  • @lacoflife
    @lacoflife5 ай бұрын

    You deserve more subs, high quality vids.

  • @Nx-hc3cv
    @Nx-hc3cv5 ай бұрын

    Your auto lights can be improved with one item a branch send 2units to the blocker the rest to your battery optimizes the solar panel don't get me wrong love your work bro keep up the grind

  • @marcosvalencia1883
    @marcosvalencia18836 ай бұрын

    Simple enough to understand hope you get more views

  • @JJ-ni2pc
    @JJ-ni2pc6 ай бұрын

    Siiick content as usual bro!! I went from not knowin anything... to setting up nih cores with so much energy i dont know what to do with it!! Keep it coming!! Last thing turn the music down a bit 😖

  • @JohnWillikers

    @JohnWillikers

    6 ай бұрын

    Okay I will make sure to turn my music down. Thanks for the nice comment and constructive criticism!!!

  • @unhingedcrouton
    @unhingedcrouton5 ай бұрын

    I cant believe the Ninth Circuit didnt make it.

  • @lilfish5245
    @lilfish52455 ай бұрын

    Im super exicited to use nih core for my 5 ceiling light and a heater😈

  • @tomaswallaitis604
    @tomaswallaitis6044 ай бұрын

    Thank you this is very helpful! Ur like teaguytom but electricity

  • @AnthonyTrimble
    @AnthonyTrimble6 ай бұрын

    Great vid. You should drop the music in the bg, in my opinion.

  • @SaltSeasDev
    @SaltSeasDev6 ай бұрын

    Your auto furnace can be made more auto-y, but requires you add 9 more power. A far better trade off than having to press the button and replace the igniter every day. [Ore Filter Pass ]--->Furnace On | Furnace Passthrough ---> Furnace On | Furnace Passthrough (etc, down the line of furnaces)

  • @industrialcrafter4889

    @industrialcrafter4889

    6 ай бұрын

    no need to replace igniter every day you just press button every restart and thats all

  • @SaltSeasDev

    @SaltSeasDev

    6 ай бұрын

    @@industrialcrafter4889 Igniters break after 12 or so uses. If you use the on switch it also accounts for server restarts too.

  • @industrialcrafter4889

    @industrialcrafter4889

    6 ай бұрын

    @@SaltSeasDev no they dont break after 12 uses

  • @industrialcrafter4889

    @industrialcrafter4889

    6 ай бұрын

    @@SaltSeasDev they take around 1hp every use and they have 250hp

  • @Icedkule
    @Icedkule6 ай бұрын

    the furnace circuit is pointless. blocking the power to the splitters from the branch output does nothing for power consumption so even though your furnaces is are off you will still be using the same rust watts from the battery. its best to feed furnaces with the power out side of a branch.

  • @Lucas-di6db

    @Lucas-di6db

    2 ай бұрын

    All u have to do is change the branch out to the furnaces and power out to conveyor and but blocker before all the splitters for furnaces

  • @davidbross5438
    @davidbross54384 ай бұрын

    The Minecraft music near the end....

  • @bananaboat1795
    @bananaboat17956 ай бұрын

    Very informative video with useful circuits. Background music in the auto smelter segment way too loud. Otherwise very good. GG

  • @jellesPipes
    @jellesPipes5 ай бұрын

    with the raid detection system you can use memory cell right instead of counters?

  • @pvemaster9732
    @pvemaster97325 ай бұрын

    Great job, only the backround music was kinda loud for my taste

  • @speedy7199
    @speedy71994 ай бұрын

    is it possibel to have 4 batterys or more and when 1 gets destroyd the power is still on the other 3?

  • @chelloho
    @chelloho6 ай бұрын

    I wouldn't recommend using that backup circuit, because after a few seconds the first 2 batteries will want to replace the backup batteries again. This back and forth will continue forever. Maybe you could use 1 blocker per battery pack, and 1 memory cell to completely drain 1 battery pack at a time.

  • @challengeman101

    @challengeman101

    5 ай бұрын

    I noticed this issue with the circuit as well, I've made circuits which do this, but you don't need another memory cell. With one extra blocker, you can just use another OR switch with each, so the output of the OR switch goes to block passthrough, each OR switch has an input connected to the opposite bank's electrical branch branch out (left at 2 watts). The other OR switch inputs come from a splitter. The original blocker is removed and the NIH core splitter only has 2 outputs (not 3) for the memory cell so set to 3 instead of 4. Add another electrical branch after the NIH core splitter branch which needs 5 power, finally, the power out of that branch goes to the charging splitter. For each bank it goes 2xbattery -> root combiner -> blocker - > branch, power out going to the core OR switch. Hope I wasn't too difficult to understand, figured I'd share my design here (adapted from Cableguy Rust which used 1 battery). There's not much point IMO in using this video's design for the first bank to be left draining for no reason while using the other bank when only a few more components would fix the issue. I might copy/paste the comment.

  • @Earendur08

    @Earendur08

    5 ай бұрын

    @@challengeman101I think this is fixed with two blockers. Since this system has two batteries supplying a required 200 power, they are root combined and the Nih Core charges both batteries from the splitters. After the each root combiner on the battery outputs put one blocker then one branch. Batteries -> root combiner -> blocker -> branch. Send an output from each branch to the opposite blocker, then the other output to the OR switch. Whether you use the configured side of the branch or the output side of the branches to do the blocking is a preference I believe. What will happen here is one side will block the other side. Whichever happens first will be based on how rustricity flows. They cannot block each other at the same time. When the side that is blocking the other side runs out of power, it will allow the other side to now pass and block the first side. Now the first side can charge up to full while the second side holds on. It will hold on until restart which may cause them to switch again, or until it itself runs out of power. In which case, it will stop blocking the original side again and then the original side will take over and block it. I haven't yet tested this, but I'm going to test it as soon as I can and I think the theory is sound.

  • @CyrillicTM
    @CyrillicTM5 ай бұрын

    Wanna know what THE best circuit is? The auto-empty-base circuit. Have your lootroom hooked up to like 16 externals. Rust+ signal to empty the entire base. Rust+ to get it all back when u come back to base :D

  • @challengeman101
    @challengeman1015 ай бұрын

    An issue with the battery backup shown in this vid is that the first pair of batteries will continue discharging even when the second pair are being used. With a few more components and by adjusting your NIH core you can prevent the issue. Use 1 blocker right after each root combiner. Use another OR switch with each, so the output of the OR switch goes to block passthrough, each OR switch has an input connected to the opposite bank's electrical branch branch out (left at 2 watts). The other OR switch inputs come from a splitter. The original blocker is removed, and the NIH core splitter only has 2 outputs (instead of 3) for the memory cell so set to 3 instead of 4. Add another electrical branch after this NIH core splitter branch which needs 5 power (which goes to the splitter then the two OR switches then blockers), and finally, the power out of that branch goes to the charging splitter. For each bank it goes 2xbattery -> root combiner -> blocker - > branch, branch out going to OR switch (then blocker), power out going to the core OR switch. Hope I wasn't difficult to understand, figured I'd share my design here (adapted from Cableguy Rust which used 1 battery in each bank).

  • @TheDemethar

    @TheDemethar

    5 ай бұрын

    why should i use nih core when i can just plop another turbine?. nih setup is like 15 power by itself. i fail to see the necessity tbh.

  • @Earendur08

    @Earendur08

    4 ай бұрын

    @@TheDemetharThe nih core only costs two rust watts when power production meets the required amount. The idea is to reduce the 20% hit on everything that happens when you go through batteries exclusively. If you are just a zerg with a giant base, it's not that important. A ford pickup truck will drive in the alps just fine but a ferrari would do it better. The nih core is the ferrari.

  • @masterjack8222
    @masterjack82226 ай бұрын

    I hear Luigi's mansion i upvote

  • @rylockgaming4642
    @rylockgaming464217 күн бұрын

    My comment is more towards the production of the video I would just make sure to adjust your music and voice levels so they don't over power each other. Some places your music is over powering your voice and makes it hard to hear in headphones.

  • @JabbRust
    @JabbRust5 ай бұрын

    Great Videos but maybe could you turn the music level just a little bit down i feel like im fighting to listen to some of the stuff your saying because this music is so defenening

  • @bigalex52
    @bigalex525 ай бұрын

    The auto furnace setup kinda defeats its own purpose by using a branch for power. The power consumption on a branch off side is always counted as active use, regardless if the power is used. Having the blocker there does not affect this at all. So it doesnt matter if the furnaces are on or off, the circuit will draw the same. To fix this I would suggest running the power through the both conveyor passthroughs and into the blocker, leave the branch out entirely.

  • @Earendur08

    @Earendur08

    5 ай бұрын

    but if you have a power bus to deliver the power to this system that would still require a configured branch. You way would work only if you weren't using a nih-core, and it it was on the last branch output from your power bus.

  • @giladbaruchian7522
    @giladbaruchian7522Ай бұрын

    Why do you need the lighter for the furnaces? They have a turn on input. Also the lighter takes damage each time you toggle it, how do you deal with that?

  • @JohnWillikers

    @JohnWillikers

    Ай бұрын

    This is an old design before the recent electrical changes. Logic circuits used to add compounded rust watts cost. So it was easier to just cut power. And use an igniter to turn them on whenever the server turned them off on restarts. So you would only click the button a max of like 28 times. Which is wouldn't even come close to breaking the igniter.

  • @DEGENRUST
    @DEGENRUST6 ай бұрын

    leveling up from my favorite base boyfriend. Thanks for helping others grow :)

  • @uutanapatta
    @uutanapatta4 ай бұрын

    good vid, more explanation for the blockers/and switches would be helpful. please please no more shty nintendo music in the background though

  • @superwassou
    @superwassou4 ай бұрын

    The music while talking 😫

  • @WoWDontu
    @WoWDontu5 ай бұрын

    Great info. Turn down the music a tad.

  • @unknownwierdo1
    @unknownwierdo16 ай бұрын

    Instead of counters couldn't you use AND, XOR or was it OR switches or something because they didn't consume any power?

  • @JohnWillikers

    @JohnWillikers

    6 ай бұрын

    That used to he the case, but now all the different switches in the game cost 1 power

  • @srm42069

    @srm42069

    6 ай бұрын

    If you use a conveyer and link them all via the filter fail branch then the total usage of the circuit will only ever be 3 power. The filter fail generates 1 free power upon failure.

  • @industrialcrafter4889

    @industrialcrafter4889

    6 ай бұрын

    @@JohnWillikers no, and still uses 0 power

  • @industrialcrafter4889

    @industrialcrafter4889

    6 ай бұрын

    @@JohnWillikers for example in your auto furnaces you had 2 filter fails going to and but output is still 1 so AND gate dont use any power

  • @Misterscout
    @Misterscout6 ай бұрын

    Awesome vid but damn turn that music down.

  • @BloxiYouTuber
    @BloxiYouTuber3 ай бұрын

    Please turn down he background music. Other than that great video. Thanks for sharing

  • @dattEnasdf
    @dattEnasdf4 ай бұрын

    Good video, but man - lower the freaking background music..

  • @mingo3585
    @mingo35855 ай бұрын

    WHAT IS UP WITH THIS MUSIC BRUH LIKE ITS A DISNEY MOVIE GOD DAMN I CANT HEAR YOU

  • @c0wb0yTV
    @c0wb0yTV4 ай бұрын

    i dont know what a nih cor is or what it does anyone want to share?

  • @JohnWillikers

    @JohnWillikers

    4 ай бұрын

    A Nih Core basically routes incoming Power Generation to Pay for your circuits first, then spends the rest on the battery. If power generation falls below power requirements, then all power is sent to the battery and the battery pays for power costs. The reason we do this is because a Battery has a 20% tax on it. If we sent 100 power to the battery we end up only storing 80. So instead if we had a power requirement of 90 we would send 10 to the battery, storing 8. Which means we would have lost 2 power instead of 20.

  • @c0wb0yTV

    @c0wb0yTV

    4 ай бұрын

    ok that makes sense, i was using an OR switch to pick between battery and live power that sounds like the same thing, I'm going to build yours so I can understand it, thanks for replying!@@JohnWillikers

  • @cowdy293
    @cowdy2935 ай бұрын

    i never have to turn on my electric stoves on any server after a restart LOL Idk what ya doin or what ya smokin lol But i dont need a button to turn mine on, that are ALREADY on lmao

  • @Earendur08

    @Earendur08

    4 ай бұрын

    I think it's because if they are off (in this case, power removed) when the server shuts down for restart it just defaults to off because they are unpowered.

  • @JohnWillikers

    @JohnWillikers

    4 ай бұрын

    What servers do you play on? I play on Rusty Moose and Rustoria official servers and they always default to off for me.

  • @cowdy293

    @cowdy293

    4 ай бұрын

    Mmm... Good point.... Never thought of it, but I usually play on lightly modded vanilla servers. So it may be the reason... I never usually play straight vanilla, to boring and tedious for my liking lol Nonetheless, love watching your videos of how educational they are!

  • @zahardude5749
    @zahardude57496 ай бұрын

    6:40 2:24

  • @calmuuu
    @calmuuu6 ай бұрын

    Me personally I hate Nih Cores, mainly because they are super annoying sometimes and can be a pain in the ass. But other than that great video 2.6/3.1 would reccomend

  • @exknoll4755
    @exknoll47555 ай бұрын

    &&@$ your background music.

  • @def6420
    @def64205 ай бұрын

    You can do auto light easier. Just use blocker and branch from red cell. If the solars have power then the light is on. Simple.

Келесі