www.homebuildingandrepairs.com Visit our website to learn more about plumbing, home repairs and new house construction. This is project #1 and the first video in a series I plan on making for do it yourselfer's, architects, engineers and plumbers who want to learn more about plumbing drain pipe assembly and building codes.
The plumbing codes in most of this video can be found in chapter nine of the Uniform Plumbing Code Book. Others can be found in International Plumbing or Residential Building Code Books and this seems to be creating more issues that I will address in future videos.
• Toilet And Shower Wet ... Plumbing playlist of more videos like this one.
How Dry Vents Can Connect To Wet Vent Plumbing Drain Pipes - Shower And Toilet - Project #1 - Q&#1 • How Dry Vents Can Conn...

Пікірлер: 47

  • @homebuildingandrepairs3122
    @homebuildingandrepairs31224 ай бұрын

    kzread.info/dash/bejne/oXuZz5WrlbXgipc.html Here's our playlist for more plumbing questions and answers. First Updated Video - How Dry Vents Can Connect To Wet Vent Plumbing Drain Pipes - Shower And Toilet - Project #1 - Qkzread.info/dash/bejne/oYyZrc58l7LNd7w.html You should always check with your local building department to see what they approve.

  • @muffinsmuffins8074
    @muffinsmuffins80742 ай бұрын

    Thank you sir, keep them coming

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    2 ай бұрын

    Will do!

  • @jacobmiller7175
    @jacobmiller71757 ай бұрын

    Thank you for sharing, it's a very specific topic considering, as you showed slight changes in drain length from fixture to main drain cause issue. However, it helps anyone to imagine how their specific needs should be approached. The 3D modeling is so nice to see compared to 2D scribbles on a dry erase board. Thanks again!

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    6 ай бұрын

    You're welcome and thanks for the kind words.

  • @VP411Designs
    @VP411Designs6 ай бұрын

    Awesome video thank you

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    6 ай бұрын

    Glad you enjoyed it

  • @joshcowart2446
    @joshcowart24463 ай бұрын

    One issue is you can’t connect both fixtures at the same place. In many places double y’s cannot be laid on their side. This is because if you turn one side up slightly to get fall then the other side has backfall

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    3 ай бұрын

    I understand and if you can use separate wyes, then I agree. I haven't found a code that says you can use the double wye and have seen it use more than once. Let me know if anyone finds a code reference number.

  • @joshcowart2446

    @joshcowart2446

    3 ай бұрын

    @@homebuildingandrepairs3122 it’s new to me. I’ve always used them and just laid them level and then graded with the pipe. Even if flat it’s less than an inch of distance that’s flat. However I’ve been flagged on it twice now and I’ve heard this in other groups.

  • @Grrrnthumb

    @Grrrnthumb

    3 ай бұрын

    ​@@homebuildingandrepairs3122 We did share the code reference with you on the other video last month. The double wye violates the 1/4"/ft slope rule, both for fitting itself and for pipe that is force to come off flat or negative off of it. Also violates the code that requires you to follow manufacturers' instructions on all listed devices, which is violated when you do not fully seat the pipe into fitting to tweak the long connected drainage run into having some slope. Plus they clog frequently. It's 100% a code violation

  • @charlesviner1565
    @charlesviner15657 ай бұрын

    👍thanks for the video

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    6 ай бұрын

    Any time!

  • @Calakapepe
    @Calakapepe4 ай бұрын

    lol wow Im confused 😅 Gotta watch this a couple times

  • @Zach-ls1if
    @Zach-ls1if4 ай бұрын

    Oh my god, you just made this make sense about not wanting liquid to run through the top of the pipes, because that’s for the air

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    4 ай бұрын

    Awesome.

  • @Frostbbitten

    @Frostbbitten

    8 күн бұрын

    @@homebuildingandrepairs3122 , I'm glad this helped someone because I'm still confused. Even if the toilet formed a full curtain of water across the top of the pipe during a flush, the wet vent from the sink would still be open and vent appropriately. I don't get it? As the toilet is the last thing permitted on a wet vented branch, there will be no other fixtures down stream of the toilet where the venting would be interrupted.

  • @shmulis1
    @shmulis13 ай бұрын

    In the first example if we added a separate dry vent before the toilet can we have the y directly under the toilet?

  • @johnblessing9249
    @johnblessing92495 ай бұрын

    Thanks! Very helpful. If someone is under IPC (Colorado), could you use one of these layouts in a basement with an AAV (like at the sink) instead of connecting to a stack?

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    5 ай бұрын

    You will need to check with your local building department.

  • @therealSIRBOOM
    @therealSIRBOOM4 ай бұрын

    In example #3, is it possible to have a soaking tub wye into the shower drain before it enters to the main 3" line? And with that in mind, how would this work with the vanity and tub switched sides of the room but the DWV 3" going the same direction?

  • @ryansulc4232
    @ryansulc42323 ай бұрын

    will this work also with a double vanity w/cross T??? tia

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    3 ай бұрын

    I think you might be better using a fixture tee or setting it up with two separate drains coming out of the floor.

  • @skillsrobles
    @skillsrobles5 ай бұрын

    I see videos of venting through the roof because the pipe has to be vertical. Can we vent through the siding?

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    5 ай бұрын

    Yes

  • @kathyern861
    @kathyern861Ай бұрын

    And then there are the code requirements dealing specifically with the toilet. Are you aware of what venting requirements are for a toilet?

  • @Roy-ij1wq
    @Roy-ij1wq2 ай бұрын

    I think you misspoke at 7:57. The toilet appears to be the farthest fixture downstream of the vent..

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    2 ай бұрын

    Of that section or group and thanks.

  • @Minecraftangle
    @Minecraftangle2 ай бұрын

    SECTION 912 WET VENTING 912.1 Horizontal wet vent permitted. (2021 IPC CODE AND COMMENTARY) Note that fixtures connecting through a double-pattern fitting are considered to be independently connected to the horizontal wet vent. The individual fixture drains vented by a horizontal wet vent must enter the horizontal wet vent in the horizontal plane so that the connection is not below the trap weir of the connected fixture. Water closets, having integral traps that depend on self-siphoning, are exempt from this requirement. Other fixtures that are not vented by the horizontal wet vent (i.e., vented by a dry vent) can enter the horizontal wet vent horizontally, vertically or at any angle in between. Water closets, having integral traps that depend on self-siphoning, are exempt from this requirement. according to the 2023 IPC CODE and commentary. Water closets CAN enter a horizontal wet vent VERTICALLY because they depend on self siphonage AND they CAN but they dont HAVE to enter horizontally according to the information provided in this video However code in ur area may vary from code in my area, AKA take what I say with a grain of salt, especially if your state, province, etc uses UPC or any other plumbing code

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    2 ай бұрын

    Wonderful and thanks.

  • @edkhoshaba170
    @edkhoshaba1703 ай бұрын

    Can you hook up 2 toilet and 2 shower and 2 sinks in one 3 inches abs pipe? I just want to make sure. it’s all in underground one story house no basement it’s all under concrete if you can let me know please thanks . I can sand you pictures if you want thanks

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    2 ай бұрын

    You can have 36 fixture units on a 3 inch drain pipe sloping 1/8 of an inch per foot. This should work for 2 toilet and 2 shower and 2 sinks in one 3 inches abs pipe. Information can be found at 2021 IPC Book - Table 710.1(1) Building Drains And Sewers.

  • @JB-jk3ow
    @JB-jk3ow4 ай бұрын

    No horizontal dry vents allowed below flood level rim of the fixture it's serving. the dry horizontal vent serving the toilet is wrong in example 10, also example 11 is wrong on the horizontal dry vent below flood level rim of the shower.

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    3 ай бұрын

    Thanks

  • @mattstiglic

    @mattstiglic

    Ай бұрын

    Long Island NY plumber here, we run horizontal dry vents all the time here. Perfectly acceptable. Would be damn near impossible not to run them with the way they build houses now here.

  • @jwblount7802
    @jwblount78023 ай бұрын

    Heres something to ponder.... 912.1 Horizontal wet venting states every fixture must connect on the same level of the horizontal. In said section of the commentary the exception on the toilet. This is what it states.... "The individual fixtures vented by horizontal wet vent must enter the horizontal wet vent in the horizontal plane so that the connection is not below the trap weir of the connected fixture. Water closets, having integral traps that depend on self siphoning, are exempt from this requirement". With that being said saying a toilet draws air is not completely correct. A toilet pushes air when flushed that why a toilet does not need to be directly vented and limiting the distance for a toilet to vent is pointless... That would be section 909.1 Distance of trap from vent.

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    3 ай бұрын

    Yes, a little confusing. The I.P.C code says it a little different. I don't get the trap weir part.

  • @jwblount7802

    @jwblount7802

    3 ай бұрын

    @@homebuildingandrepairs3122 The trap weir or crown weir is the part of the bottom of the p trap where the fluids start to leave the trap and travel down the line..... The case of the video you did this would be referring to the trap weir of the shower. Once it leaves that trap it enters the horizontal wet vent and that must be on the same plane.... For example if you traveled lets say 2 feet from the shower trap to the wet vent and you double 45 down to said vent then that would not be entering the horizontal wet vent at the same plane therefor the shower would need to be individually vented.

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    3 ай бұрын

    @@jwblount7802 That's what I thought and if it's in the code, it does not make sense. It would require a little more math and fixture location might vary. To make it work, your bathtub might need to be moved a few feet in a few different directions:)

  • @jwblount7802

    @jwblount7802

    3 ай бұрын

    @@homebuildingandrepairs3122 I do it everyday just like I described and it works like a champ. I do on average 50 -60 custom homes a year on average, I did 85 of them last year and plumbed everyone of them just like this..... What I have noticed with the IPC it is more on pipe sizing, increase the pipe size and the farther away from the vent the trap can be. But as for the toilet drawing air from the shower it does not. I did a log cabin house years ago and they want ZERO vents through the roof just AAV's. I told them at least 1 has to go out for relief. Nope not gonna happen.... Within 6 months of moving in the house locked won't flush of flushes very slowly and pushing on all of the shower traps. So I went back out there drilled about 12 or more 1/4" holes in the outside cleanout..... Been flushing and draining like a champ ever since.

  • @danton624
    @danton624Ай бұрын

    It's 6 feet not 8 feet... x2 plus 2 on the diameter of pipe

  • @62Cristoforo
    @62Cristoforo4 ай бұрын

    “Vents protect traps”

  • @EricPotratzM
    @EricPotratzM4 ай бұрын

    Which examples here are not code compliant?

  • @Grrrnthumb

    @Grrrnthumb

    4 ай бұрын

    Which code are you under? #1 he already mentions is a violation (but IRC only I believe). #3, #7, & #8 have a horizontal double wye violation (lack of 1/4" per foot violates IRC & UPC). #9 he mentions is a violation, but that is actually only under the UPC.... IRC allows this. #10 & #11 show a prohibited flat vent arrangement, violates both UPC & IRC

  • @homebuildingandrepairs3122

    @homebuildingandrepairs3122

    4 ай бұрын

    @Grrnhumb I can't argue with this and don't like the double wye set up if you can avoid it, but table 706.3 in International Plumbing Code Book allows it for #3, #7, & #8. As far as #10 & #11, I've seen it done by licensed journeyman plumbers in floor framing and will address the issue more in a future video. As far as the International Residential Code And the The Uniform Plumbing Code goes, You should always check with your local building department to see what they approve.

  • @Grrrnthumb

    @Grrrnthumb

    3 ай бұрын

    ​@@homebuildingandrepairs3122 Table 706.3 does not mention a double wye, so no it does not allow for it. Examples 3, 7, & 8 are violations. When you've seen flat venting like in examples 10 & 11, that was not recent (ask your plumber). Those are flagged violations in all areas of the country now. Do you need the code sections again?

  • @Smit1730
    @Smit17303 ай бұрын

    I perforate the top of the waste lines with a 1/8” bit the entire length of the pipe. No venting needed!