The Best Oscilloscope Meter?!

Ғылым және технология

Need Help Finding Clinical Engineering Job?
Fill out this form and I will help you using my network of Hospitals and Companies:
docs.google.com/forms/d/e/1FA... XEast XE-702S Scopemeter (Zotek ZT-702S)
Find it on Amazon: amzn.to/44DBAkY
** PLEASE SUBSCRIBE! I am trying to grow this channel to deliver better content. Subscribers = Corporate Supporters =Better Content **
** Check out my playlists for Biomed Basics, Vlog, Equipment Repair, and HTM Theory. Connect with me on LinkedIn to stay updated:
/ justin-barbour-8602b886 **

Пікірлер: 24

  • @ldiazmdiaz
    @ldiazmdiaz2 ай бұрын

    Press the REL (Relative) on the power switch to remove the cable resistant.

  • @BjornV78
    @BjornV7811 ай бұрын

    This Oscilloscope meter is sold under different brands like : BSIDE ZT702S , Zoyi ZT-702S and Aneng AOS02 The big benefit of a portable scope is that you can do measurings on mains powered circuits, but it is recommended not to plug in the USB-C to a computer during these mains measurings, because almost all portable scopes have the metal outside of the BNC connected to the outside of the USB-C port, so your scope becomes grounded. Regarding the probes, these are generic pvc, but feels like silicon, i have multiple sets of these ordered a few years ago from Wish, and find them better then most probes that come with expensive multimeters. I have a set with the tips unprotected, and a set where i used red and black heat shrink to isolate the most part of the tips. 27:15 The fuses are the HRC (High Rupture Capacity) type, on most cheap multimeters they use glass fuses that can explode in pieces. 29:57 They also used brass inserts for the screws, that's also nice to see. Certainly a scope meter with good build quality. Ps: on Banggood, this scope meter is sold as BSIDE ZT702S , for arround $65

  • @ursusskandia
    @ursusskandia6 ай бұрын

    Thanks for the review - here in Europe it's the Xeast XE-702s. I am impressed as well - for 90€. You maybe want to turn your main video image 180° so it is easier to follow.

  • @robertcalkjr.8325
    @robertcalkjr.832511 ай бұрын

    Thanks! I might buy one of these scope/meters. I like that it uses the 18650. But if I buy one, I'll immediately order a new set of leads from Probe Master for it and maybe an oscilloscope probe as well. I've not seen any leads that can compare to PM. My Brymen 869s leads were the best leads that came with the meters that I've bought, and they didn't even come close to the PM leads. I did keep my high voltage/current Fluke leads and only use them and my Fluke for high voltage and current.

  • @MemoriesRR
    @MemoriesRR11 ай бұрын

    Thank you

  • @myevilbanana
    @myevilbanana4 ай бұрын

    Would this be a better first o-scope over the $30 dso152 ones you find on Amazon? Currently looking to use a scope to set my car amplifier gains correctly but past that I would like a unit that would be easy to use while learning more about electronics

  • @Larry-AK0Z
    @Larry-AK0Z8 ай бұрын

    I think it's voltage and time, not volume. The calibration button is used to calibrate the meter, not the probe. No input should be present when calibrating this function. I have owned mine for a long time and have found it to be very accurate. The best meter/scope on the market for the price. Great video, thanks.

  • @BetterBiomedChannel

    @BetterBiomedChannel

    8 ай бұрын

    Correct it's Voltage and Time. That's the problem with having a paid video editor. I would normally have found the error on playback and edit. Thanks for watching Larry

  • @w5cdt

    @w5cdt

    6 ай бұрын

    I bought one….I like it. The millivolt range is impressive…I checked it against my Fluke 341 voltage calibrator.

  • @romyjaravata238
    @romyjaravata2385 ай бұрын

    Does it have a signal generator that is helpful in trouble shooting Stereo?

  • @tecnisdaimondm.g9321
    @tecnisdaimondm.g93219 ай бұрын

    Excelente

  • @randyab9go188
    @randyab9go1888 ай бұрын

    I have a fluke 99 scope meter and way back when close to 30 years ago they used plastic BNC sockets. They even admonished you to never use a metal BNC plug as it would cause abnormal wear. Almost every scope probe uses a metal BNC male connector. The flukes were plastic. It wasn't too long ago I received an Owon scope meter and it uses a plastic socket but metal male bnc plugs on the probes. Weird.

  • @SP6QKX
    @SP6QKXАй бұрын

  • @thetechgenie7374
    @thetechgenie73746 ай бұрын

    The screw by the relay is a huge no for isolation.

  • @bernardaflores1720
    @bernardaflores17206 ай бұрын

    Can this be used w/ a low DC clamp???

  • @BetterBiomedChannel

    @BetterBiomedChannel

    6 ай бұрын

    Good question!

  • @MaheshWalatara
    @MaheshWalatara8 ай бұрын

    How the accuracy?

  • @BetterBiomedChannel

    @BetterBiomedChannel

    8 ай бұрын

    Fantastic.

  • @ldiazmdiaz

    @ldiazmdiaz

    2 ай бұрын

    kzread.info/dash/bejne/X4eGt7OEf5bFfJc.html

  • @chloeleedow7250
    @chloeleedow72507 ай бұрын

    The stand is no different from the fluke 117 metre I have 😂

  • @robertcalkjr.8325
    @robertcalkjr.832511 ай бұрын

    The best oscilloscope meters are probably the ones that I can't afford to buy.

  • @BetterBiomedChannel

    @BetterBiomedChannel

    11 ай бұрын

    The best O Scope meter is the one you use on you when troubleshooting. Most scopemeters are huge with poor battery life. The only thing this scopemeter should have, which I didn't see - is recording. Since this is less than $100 with good probes and has a temp sensor and it fits in a tool bag. This is a huge win.

  • @ldiazmdiaz

    @ldiazmdiaz

    2 ай бұрын

    @@BetterBiomedChannel It takes screen snap shot and retrieved with the computer

  • @MemoriesRR
    @MemoriesRR11 ай бұрын

    Thank you