Sunburst Chemicals - Changing A Squeeze Tube On A Low Temp ADS Dishmachine

Created on June 26, 2013 using FlipShare.

Пікірлер: 19

  • @tonybalogna1979
    @tonybalogna197910 жыл бұрын

    There's usually no need to remove the cover on that pump style. Disconnect both ends of the squeeze tube, and use the prime switch to remove and install the new squeeze tube.

  • @Matt-sl1wg

    @Matt-sl1wg

    11 ай бұрын

    This could be a matter of preference. I personally find it annoying as hell to try to put the chemical line into a squeeze tube that's still on the pump. Easier to take the tube right off the pump where I have lots of space and then just put it back on.

  • @hatfisc
    @hatfisc2 жыл бұрын

    Had a delightful disagreement with my new supervisor about the importance of tube lube. Nobody at the company im currently working for uses it and im now an outcast for not changing a tube without it.

  • @Matt-sl1wg

    @Matt-sl1wg

    11 ай бұрын

    If the company is charging for the squeeze tubes, then maybe they just want to generate more revenue. Otherwise, it extends the life of the squeeze tube and should be used on most peristaltic pumps.

  • @thomaspease208
    @thomaspease2085 жыл бұрын

    should have used the primer pump to remove it and reinstall the squeeze tube

  • @80bicho
    @80bicho8 ай бұрын

    Hi where do you buy this tubes in BC Canada ?

  • @glasser2819
    @glasser28195 жыл бұрын

    it looks like the tube length should be cut to size! Also may not be bad idea to lub the 2 ROLLERS SHAFTS but not the tube itself.

  • @karmveeryadav50
    @karmveeryadav505 жыл бұрын

    Sir I have a question on my mind. What is the life of squeeze tubes. That mean how long it work properly or after how much time it need to be change

  • @Brucesalarski

    @Brucesalarski

    5 жыл бұрын

    karmveer yadav 3/6 months

  • @trippyz5158
    @trippyz51585 жыл бұрын

    Hi sir I did change the squeeze rubber but my sanitizer is not coming what could be the reason

  • @kenschroeder5262

    @kenschroeder5262

    4 жыл бұрын

    Rahil Mogaveera have the same issue what is the answer?

  • @defiantcustomrides3202

    @defiantcustomrides3202

    2 жыл бұрын

    Line coming from the sanitizer to the squeeze tube likely has a crack. Pulling air bubbles

  • @arpadcsorba2053

    @arpadcsorba2053

    Жыл бұрын

    @@defiantcustomrides3202 I had the same issue, I replaced the line with 1/4" poly and the sanitizer still only comes out about 6" out of the bucket.

  • @lovethebatman8930
    @lovethebatman89308 жыл бұрын

    How do you adjust temp

  • @glasser2819

    @glasser2819

    5 жыл бұрын

    these new "low-temp" machines use incoming warm water at around 130°F. They have no internal heaters because the 3 chemicals are able to work at low temp and sanitation is done with chlorine alone, not hot water needed! Cheeper machines with quick run cycles...

  • @nickuroza4443
    @nickuroza44434 жыл бұрын

    Ecolab is way better then sunburst. You guys sells colored water. We sell chemical

  • @hatfisc

    @hatfisc

    2 жыл бұрын

    Ecolab no longer offers RM's a competetive wage.

  • @Christ42

    @Christ42

    2 ай бұрын

    Ecolab = greasy car salesman disguised as service techs = no service.

  • @user-ef2rm8sy9l
    @user-ef2rm8sy9l2 ай бұрын

    Is this Ecolab or Hobart lol