Sub-Zero 632 freezer not cooling

Пікірлер: 4

  • @SebastienN1940
    @SebastienN19402 жыл бұрын

    So your condenser being blocked caused the compressor electrical to overheat but you failed to realize what that does to the compressor and the subsequent system. By the way if it was just the overload and relay why would you need to recharge? You tampered/opened the system but you failed to change the filter dryer like you should have. Not only that, you are presumably leaving a temporary valve on the line and not even taking the time to solder in a new access port. If you were experienced you would know this will leak and the customer will call you back. But that's the trick isn't it.. You'll never go back and deal with the mess you've caused. Someone else gets the angry customer and they get to fix your sloppy work. Sad. No wonder it's just a "big fancy box" to you. Stay in your lane with ge or lg!

  • @fixitfelix718

    @fixitfelix718

    Жыл бұрын

    Not only that. That compressor is likely an egx70 or egx60 the relay he used is for kenmore compress 1/3 the size and he put terminals into it to reduce from 1/4 inch to 1/8... that relay will last 2 months and burn out that compressor guranteed..i dont think hes ripping them off on purpose i think hes learning and thinks he is better than he is but hes trying..he will learn The right electrical cost 28$ and new capcitor is 11$ GATOR FIND MY EMAIL AND ILL HELP YOU OUT..OTS IN MY VIDEOS..

  • @Miamibeachlife
    @Miamibeachlife3 жыл бұрын

    Great stuff.. you must love your job!!