Stripping a Starter Motor Solenoid and repair.

Stripping and Starter Solenoid the easy way. Audio sorts itself out after a minute. This is a Bosch 0331 303 solenoid but most sealed solenoids can be stripped down the same way.

Пікірлер: 26

  • @ironwolf3699
    @ironwolf369911 күн бұрын

    I don't know specifically what they are called but I like solenoids that are in like boot shaped housings. They look far easier to repair than these types.

  • @damianbutterworth2434

    @damianbutterworth2434

    11 күн бұрын

    Are they Lucas ones with 2 screws in the cap. Much easier to repair.

  • @damianbutterworth2434

    @damianbutterworth2434

    11 күн бұрын

    Oh I`ve seen some like that on Rovers. Quite big and have 3 screws holding the cap on. When you take the cover off the contacts are easy to clean. Perhaps it`s that type you mean.

  • @ironwolf3699

    @ironwolf3699

    11 күн бұрын

    @@damianbutterworth2434 yea I like those ones because I can remove the coil with just a small ish arbor press. When they are pretty hard, I just use a pipe/tube for more leverage. And that is when the coil is burnt out or the wire at the bottom needs to be re soldered.

  • @johnalbers4632
    @johnalbers46323 ай бұрын

    What type of solder are you using? silver solder for heat resistance?

  • @damianbutterworth2434

    @damianbutterworth2434

    3 ай бұрын

    Just normal solder on the solenoid cap. I want some better high temp stuff for soldering brushes on brush boxes. A spot welder would be nice if I had the money. I used to do this at Valeo and they went to using no lead solder. Was a pain to use. Solder dropping down the hole then having to strip it down again. :)

  • @ShakirAuto067

    @ShakirAuto067

    2 ай бұрын

    Nice bro 😊

  • @g.j.dutoit4447
    @g.j.dutoit4447Ай бұрын

    Why if bench test ford ranger starter, it not stay ingage if i keep small wire on pin. It uningage with start small wire on start point. It must only uningage only when i take of start thin wire, am i right or wrong? Rrrrrealy hope someone can help me. Thanks guys.

  • @damianbutterworth2434

    @damianbutterworth2434

    Ай бұрын

    Could be the holding coil is open circuit.

  • @damianbutterworth2434

    @damianbutterworth2434

    Ай бұрын

    Does it keep trying to engage. Because if the holding coil is broken. The pull in coil will engage it and then cut out and let the holding coil take over but if the holding coil is broken it will disengage and try again.

  • @damianbutterworth2434

    @damianbutterworth2434

    Ай бұрын

    If you take off the main lead from the solenoid to the motor and measure the resistance from the small power in spade connector you should get a reading down to earth and to the large motor post . If you get an open circuit when you measure to earth then it`s your holding coil which would cause it to click in and out.

  • @g.j.dutoit4447

    @g.j.dutoit4447

    Ай бұрын

    @@damianbutterworth2434 you mean that the solinoid coil not getting power after a while (seconds) It ingage then even with start wire still connect bendix gear ungage.

  • @g.j.dutoit4447

    @g.j.dutoit4447

    Ай бұрын

    @@damianbutterworth2434 aaaa okay got you. That i dont no. I take of starter small wire just after it disengage. I will try totay to still keep the starter wire on after it disengage to see if it engage again. Thanks for the advise. Will tell you later on if it engage again if hold starter wire on even if it disengage. 😉