Steps to Troubleshooting Appliances. Whirlpool Dryer Wiring Diagram

Ойын-сауық

We talk about the steps we take to troubleshoot a Whirlpool Electric Dryer Wiring Diagram.

Пікірлер: 46

  • @richardshaules3981
    @richardshaules3981 Жыл бұрын

    The presenter is a natural teacher. I would happily sit and learn from this man any day

  • @peterwachter7753

    @peterwachter7753

    6 ай бұрын

    Absolutely. An immensely enjoyable learning experience.

  • @desertdispatch
    @desertdispatch2 жыл бұрын

    I like the way he teaches. Much easier than others.

  • @ronmccarty7537
    @ronmccarty75372 жыл бұрын

    This instructor is AWESOME!!!

  • @bill98778
    @bill987782 жыл бұрын

    Thank you so much sir for your efforts, plus one more thing I loved, just when you teaching, your students are very polite and good listeners, and once they get chance to speak, they don’t play they stick on the subject, that’s good, keep going

  • @MentalKaos53
    @MentalKaos532 жыл бұрын

    Great presentation and educational video. This is brilliant. I'm diggin' the way you teach,very easy to learn from.

  • @octaviooro9182
    @octaviooro91822 жыл бұрын

    Hello Richard, always learning more and more from this excellent videos keep up the good work.

  • @Scorpio69birthright
    @Scorpio69birthright2 ай бұрын

    Great teacher, I learned a lot fast from you.

  • @scapellisappliancerepairs
    @scapellisappliancerepairs2 жыл бұрын

    New video to start the day 💪🏻💯 LETS GO!!!!!!!

  • @luxorra2727
    @luxorra27272 жыл бұрын

    Really helped me a whole lot. No more ohming out for me.

  • @tonytony6912
    @tonytony69122 жыл бұрын

    Excellent video

  • @TMMApplianceRepair
    @TMMApplianceRepair2 жыл бұрын

    Excellent video @RichardZilka

  • @user-ru2uc4hz8i
    @user-ru2uc4hz8i Жыл бұрын

    Awesome sir thank you very much. You are great sir. Thanks upload for this video

  • @seanstrickley3992
    @seanstrickley3992 Жыл бұрын

    It all makes sense now ty

  • @Theleadersofthenewschool
    @Theleadersofthenewschool Жыл бұрын

    Amazing 👉🏾✨✨✨

  • @williegillie5712
    @williegillie57124 ай бұрын

    A question: instead of checking for volatsge in various locations why not have it unplugged and check the whole circuit with an oh meter. Obviously when you get to the centrifugal switch you’ll have to plug it in and run it to test that component. The rest would only need an ohmmeter because you can hook it to each end of the cuircut L1 and L2 and if any component in the circuit is bad it will read open. Am I correct. I’m thinking more for safely using the ohm meter is safe and easy.

  • @ausseamore8386
    @ausseamore83869 ай бұрын

    Thanks for sharing

  • @MrGuachupita
    @MrGuachupita2 жыл бұрын

    Excellent

  • @kevinkillsit
    @kevinkillsit Жыл бұрын

    This is what they should you in school.

  • @atabak1987
    @atabak19872 жыл бұрын

    I always enjoy your informative and easy to understand videos. I was wondering where would I be able to get the service manual if it’s not inside the unit? Thank you

  • @riz65

    @riz65

    2 жыл бұрын

    I replied twice, but for some reason youtube does not let response post reach out to me from our website, and I will get you information.

  • @michaelvinalon3415
    @michaelvinalon34152 жыл бұрын

    Excellent video lecture on components and troubleshooting ! Where are the class dates listed ? Thanks

  • @riz65

    @riz65

    2 жыл бұрын

    Brother B and I are working out a schedule for all training this year will be posted on the website calendar soon.

  • @1stFlyingeagle
    @1stFlyingeagle2 ай бұрын

    Question: Could you tell me what is an outstanding source for finding fire diagrams?

  • @gugagugadj4464
    @gugagugadj446419 күн бұрын

    How can I sign up for his classes guys? Any recommendations please 🙏

  • @volpe1970
    @volpe19702 жыл бұрын

    Hello Richard. Another awesome video! This content is exactly what I need to become a better appliance tech! Thank you! I don't understand the abbreviations on the diagram. For example: FS1 FS2 RE, etc. What do those letters stand for? Thanks, Rudi from Richmond. Hope to catch another live class soon.

  • @riz65

    @riz65

    2 жыл бұрын

    FS1 and 2 these are just abbreviations of the part name Fuse safety "FS" 1 and 2 just is the p[lace where the wires connect. RE is the start relay. M1 M2 What do you think the M means? and H1 and H2 what are they for, look at diagram and might be easer than you thought.

  • @volpe1970

    @volpe1970

    2 жыл бұрын

    @@riz65 M for motor, H for heater..etc. Thanks Richard for indulging my questions. You da man!

  • @richardzilka8151

    @richardzilka8151

    2 жыл бұрын

    @@volpe1970 Perfect

  • @douglasduda6890
    @douglasduda6890 Жыл бұрын

    Do you sell safety gloves? Thank you

  • @mostlikelywedoitservices6926
    @mostlikelywedoitservices69262 жыл бұрын

    Do you have a video on wiring on a duel valve solenoid on a gas dryer? With so many direct wire connections I just don't see how the flow works and why.

  • @TMMApplianceRepair

    @TMMApplianceRepair

    11 ай бұрын

    Sorry for late response I don't get time to keep up with comments, We do have a video on the gas dryer burner here. Gas Stoves and Dryers - kzread.info/dash/bejne/ZmyWwZJskdKcdtY.html

  • @justinkeller7471
    @justinkeller7471 Жыл бұрын

    Good evening. I have a Roper dryer and when I press the start switch I get a hum coming from the motor. I took it apart and put a test lead on the motor tabs and plugged into a 120v outlet and the motor turns on no problem. I ordered a brand new motor and installed it and I still get the same humming noise as I did with the old motor. Any suggestions? The push to start has continuity, the door switch is functional, thermal fuse and thermostats etc are all good as well. I am stumped.

  • @appliancetraining5600

    @appliancetraining5600

    Жыл бұрын

    you need to check the voltage to the motor, that would be 4m and 5m white and blue, when pressing start make sure you have 120v there

  • @justinkeller7471

    @justinkeller7471

    Жыл бұрын

    @@appliancetraining5600 I figured it out. I was trying to hook the dryer up in my shop which has a subpanel in it that is fed from my house. In your house panel the ground and neutral are bonded together however in a subpanel the ground and neutral should not be bonded (seperated) therefore a 3 prong dryer cord (2 hots and a ground) will not run a dryer motor because a neutral is needed to complete the circuit in a 120v motor. I put the dryer next to my compressor and had planned on using the outlet for my air compressor or dryer which ever was needed. The outlet worked fine for my 240v air compressor because for a 240v motor you only need 2 hots and a ground and a nietral is not needed. As I was standing there after tracing every wire and testing everything again and again for continuity etc on the dryer it finally hit me what was going on. I went over to my subpanel and took a scrap wire and bonded the ground and neutral bus bars together and the dryer started working great!!! Thanks for all yalls help and suggestions!!

  • @richardzilka8151

    @richardzilka8151

    Жыл бұрын

    @@justinkeller7471 glad you were able to figure it out

  • @justinkeller7471

    @justinkeller7471

    Жыл бұрын

    @@richardzilka8151 thank you. Your videos are very informative!

  • @EurekaRecycler
    @EurekaRecycler Жыл бұрын

    this one dont turtn on, please help

  • @stratstrangler22
    @stratstrangler2211 ай бұрын

    can you do that same test for continuity instead of voltage if your not able to access power.

  • @TMMApplianceRepair

    @TMMApplianceRepair

    11 ай бұрын

    continuity test really should only be made on individual components, wires or controls, Continuity unless completely understood to test a circuit is hard. You would have to completely isolate that circuit where voltage checks the circuit not the component.

  • @stratstrangler22

    @stratstrangler22

    11 ай бұрын

    @@TMMApplianceRepair Hey I appreciate you responding very much. One very important question I personally have for you is what you’re explaining in this video when you’re checking these voltages are you checking this while the machine is running?this is a different style of testing that I’m used too. That was the only thing that had me a little confused

  • @bukursglass6990
    @bukursglass69909 ай бұрын

    I get so confused on how if the motor is the problem, but yet the components after the motor are still getting voltage? Wouldn’t everything after the motor not get voltage if the motor was bad ?

  • @ronaldpate8097

    @ronaldpate8097

    3 ай бұрын

    Man I’m glad I’m not the only one. Im sitting here wondering why this ain’t making sense. Im wondering if maybe my mom drank too many mad dog 20/20’s when she was pregnant with me and now I’m dumb

  • @bobgosch4340
    @bobgosch434011 ай бұрын

    What Presentation Software is being used here? Very interesting...

  • @TMMApplianceRepair

    @TMMApplianceRepair

    11 ай бұрын

    Activeinspire

  • @mostlikelywedoitservices6926
    @mostlikelywedoitservices69263 ай бұрын

    Another problem. There is no wire diagram because it grew feet and left. What then. it is a scramble on the net trying to find the one you need,