Staggering of Bar and Lapping Zone problem in Building Construction I Know Solution as per IS Code

Staggering of Bar and Lapping Zone problem in Building Construction I Know Solution as per IS Code
Know More: contechxs.com/rebar-coupler/
Phone: 9549549543
Email: 9549549543@contechxs.com
Welding, Lapping, Coupling of Reinforcement in Column and Slab - Which is Best
• Welding, Lapping, Coup...
What To do if Lap in Column Comes in Zone A
• What To do if Lap in ...
Which Bar should be Staggered during lapping in Column? | Upper or Lower
• Which Bar should be JO...
Reinforcement lapping Zone as per IS Code 13920 in Column
• Reinforcement lapping ...
Staggering of bar and lapping zone problem in building construction: stagger every bar with rebar coupler is the solution
#Lapping #Coupler #staggering
Disclaimer - This video is for educational purposes only. Copyright Disclaimer under section 107 of the copyright act1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship and research. Fair use is a use permitted by copyright statute that might otherwise be infringing. Non-profit educational or personal use tips the balance in favour of fair use.

Пікірлер: 26

  • @parvindra29
    @parvindra2910 ай бұрын

    Use full this video is solved my problem and confusion

  • @vishaljaiswal1440
    @vishaljaiswal1440 Жыл бұрын

    Sir app please video banaya kijiya jaldi hum log ko bahut intzar rehata hai❤️❤️

  • @sailendranathvemulapati
    @sailendranathvemulapati11 ай бұрын

    If the length of the column rod left for the higher floor is less where we cannot lap it sufficiently, how can a coupler be used?. The existing rod cannot be threaded.

  • @vishalsharma2290
    @vishalsharma2290 Жыл бұрын

    Hello sir... Please ek video is pe b bnana... Mujhe first floor bnana hai... Magar mere column ka steel slab se bahar nahi aaya hua hai... Vo steel slab k bottom tak hi hai. to us case me column ki bars ko continue kaise kre...

  • @subhankardua7112
    @subhankardua7112 Жыл бұрын

    Sir,non structure wall me q vertical ko floor to floor hota hay usko age Tak q nahi leta hay

  • @anandkumar5260
    @anandkumar5260 Жыл бұрын

    सर नमस्कार अगर छत के ऊपर स्लैब में सभी एक समान छड़ कट गए हैं तो क्या उसको वहीं पर कौपलर देकर कॉलम दूसरी मंजिल के लिए उठा सकते हैं क्या बताने का कष्ट करेंगे क्या पूरे छत पर बीम देकर कॉलम उठाया जा सकता है

  • @maheshj660
    @maheshj660 Жыл бұрын

    Agar site par column mein lower floor par 20mm dia vertical rebar hai , aur upper floor par 25mm dia hota (lower to higher dia) hai then us case mein couple kaise kaam aayega please explain , muze konsa rebar kaha terminate karna hoga aur kaha se jodna hoga

  • @cgogoi8952
    @cgogoi8952 Жыл бұрын

    Kya ground floor ma hi column ka joint da sakta haa. Kya ya safe haa

  • @siddhartsrivastava2883
    @siddhartsrivastava2883 Жыл бұрын

    3 मंजिल बिल्डिंग के लिए फाउंडेशन से सरिया को कितनी ऊंचाई तक पहले बार काटते हैं यदि फाउन्डेशन से प्लिंथ बीम 10 फीट हो और उसके बाद छत 11.50 फीट हाइट हो तो पहला लैपिंग कितने हाइट पर रखेगे

  • @amols9634
    @amols9634 Жыл бұрын

    Coupler Lagane k liea jo thread bnate h us se to steel ka strength Kam ho jata h na sir

  • @LearningCivilTechnology

    @LearningCivilTechnology

    Жыл бұрын

    Usme pehle forging karna hota hai.. jisse uski dia badh jati hai.. uske bad threading karte hai

  • @sabyasachipal4991
    @sabyasachipal4991 Жыл бұрын

    Sir, Agar Lapping zone top bar mein galat jaiga par Jaye....use khole bina hum kya (3*Lapping length) ka or ek tisra rod ko use mein la sakte hei?

  • @sabyasachipal4991

    @sabyasachipal4991

    Жыл бұрын

    In case of beam.

  • @homeplan3532
    @homeplan3532 Жыл бұрын

    Practically sariye ka wastage na ho isliye sariye ko ek hi length rakh dete hai Jayda tar log

  • @homeplan3532
    @homeplan3532 Жыл бұрын

    Sir mein house construction karwa raha hoon mujhe column mein problem ho Rahi hai aap meri help kar sakte hai

  • @Perfectvlog74
    @Perfectvlog7411 ай бұрын

    Agar 4 rod ek jaga pe laping pare toh Kia karna cahiyea ?

  • @digitalatoz.
    @digitalatoz. Жыл бұрын

    Hello I'm BabulT from Dhaka,Bangladesh. However can you help me please I've need details for couple's purpose.

  • @haqi76
    @haqi76 Жыл бұрын

    16 mm aur 20 mm bar mau coupler ya but weld use kr saktay hain

  • @LearningCivilTechnology

    @LearningCivilTechnology

    Жыл бұрын

    Yes

  • @tinkurathore3417

    @tinkurathore3417

    Жыл бұрын

    Aap har dia me use kar skte ho, 16 to 40mm, coupler lagane se number of joints bhi kam hote hai

  • @LearningCivilTechnology

    @LearningCivilTechnology

    Жыл бұрын

    Ha .. 9549549543 ispe call kar ke aap baat kar ke guidance v le sakte hai

  • @luckysingh-ej8if

    @luckysingh-ej8if

    Жыл бұрын

    yes you can use coupler

  • @ironman2600
    @ironman2600 Жыл бұрын

    Sir Coupler For 16 mm Bar Kahan Milega ??

  • @kirankumarsa4555
    @kirankumarsa4555 Жыл бұрын

    Sir.. my question is in building surveying .. which are the level that surveyor give... for example columns points sill level like that in total building that surveyor give every levels in building Construction am waiting for u r answer...

  • @civilandknowledge6548

    @civilandknowledge6548

    Жыл бұрын

    Surveyor give point only in TBM.after this u can transfer level

Келесі