Split air conditioner water leakage

For Course Details, WhatsApp 9082044810
कोर्स की जानकारी के लिए WhatsApp 9082044810
1) Basic Refrigeration & Air Conditioning
2) HVAC Maintenance
3) Heat Load
4) Duct Design
5) Piping Design
6) Cold Storage
Notes
girishshindeacademy.blogspot....
Available Course / उपलब्ध पाठ्यक्रम
drive.google.com/drive/folder...
E Mail :- girishsshinde@gmail.com
/ girishshindehvac
/ girish_shinde_academy
www.amazon.in/shop/girishshinde
#girishshinde #airconditioning #hvac
Image Source in Video
www.freepik.com/
commons.wikimedia.org

Пікірлер: 15

  • @user-rz5qf2mj5w
    @user-rz5qf2mj5w Жыл бұрын

    Good video sir

  • @sheikhnadeemalam5813
    @sheikhnadeemalam5813 Жыл бұрын

    nicely explained

  • @SHARMA_89
    @SHARMA_89 Жыл бұрын

    Sir ek video humidity fire pe bhi bnao Jo main unit k sath lgi hoti h cold chamber mein

  • @bazrazin1
    @bazrazin1 Жыл бұрын

    my voltas 1 ton split is blowing droplets of water from the right half side towards the blower motor,t when used at turbo speed , low/med/ high not much droplets , air filter & drain tray are fully clean 1 liter bottle can be emptied in 1/2 minute, is it pulling drops directly from the cooling coil & throwing out, compressor running current is 3.4A.

  • @girishshinde

    @girishshinde

    Жыл бұрын

    This may happen at High humidity area, check for any openings to the room or water source in room because of high humidity more water condense on coil and part of water may suck by blower at High speed

  • @bazrazin1

    @bazrazin1

    Жыл бұрын

    @@girishshinde it was not happening earlier, from 2 weeks , even i heavy monsoon never blew out droplets, from the current gas charge seems ok, could it be half of the drain tray could be obstructed by dirt causing drain water falling on the blower.

  • @manojnayak6876
    @manojnayak68767 ай бұрын

    💞आप का ही एक अज्ञात शिष्य हूं श्री मान माफी चाहूंगा कि यदि छोटा मुंह बड़ी बात कहूं 🙏 एक कारण एसी में इंडोर का सही लेवल में लगा न होना भी है ...🧑‍🔧

  • @girishshinde

    @girishshinde

    7 ай бұрын

    ji haa

  • @biswajitnandi976
    @biswajitnandi976 Жыл бұрын

    Sir plz mera question solve kr dijiye

  • @biswajitnandi976

    @biswajitnandi976

    Жыл бұрын

    Air cooled plant me R-134A refrigerant ki pressure KPA ME kitna hona chahiye DISCHARGE OR SECTION ME

  • @biswajitnandi976

    @biswajitnandi976

    Жыл бұрын

    Sir ek br bata dijiye

  • @girishshinde

    @girishshinde

    Жыл бұрын

    @@biswajitnandi976 1250 kpa ke aas pass

  • @prajapatishiv4632

    @prajapatishiv4632

    Жыл бұрын

    ​@@biswajitnandi976 suction pressure 300 Kpa and discharge pressure 1300 kpa oil pressure 1209 kpa Economiser pressure 600 kpa

  • @biswajitnandi976

    @biswajitnandi976

    Жыл бұрын

    @@prajapatishiv4632 thank u sir