Solar panel wiring using Two charger controllers

Ғылым және технология

solar panel wiring using using two charge regulators
WATCH THESE VIDEOS ALSO
SOLAR WATER HEATER CONNECTION
• HOW TO DO SOLAR WATER ...
SIMPLE COMPLETE HOUSE WIRING
• Complete Single Room W...
TWO WAY SWITCH WIRING
• HOW TO DO SINGLE PHASE...
SOLAR PANEL CONNECTION IN SERIES
• How to connect 8 sola...
COMPLETE HOUSE HOUSE WIRING
• Complete house wiring ...
HOW TO DO SIMPLE SOLAR HYBRID POWER SYSTEM 3KW AT HOME/CONNECTION/WIRING /DIAGRAM/VIDEO / ANIMATION
• HOW TO DO SIMPLE SOLAR...
HOW TO DO SIMPLE COMPLETE HOUSE WIRING//CONNECTION//DIAGRAM//VIDEO
• HOW TO DO SIMPLE COMPL...
GEYSER WATER HEATER WIRING DIAGRAM/INTERNAL CONNECTION/ANIMATION/VIDEO
• GEYSER WATER HEATER WI...
How to connect solar panels in parallel/how to wire solar panels in parallel/Diagram
• How to connect solar p...
Ring circuit wiring diagram/ring socket connection/wiring/diagram/connection
• Ring circuit wiring di...
RICE COOKER WIRING DIAGRAM
• RICE COOKER WIRING DIA...
how to do internal connection of electrical flat iron/ repair/ diagram
• how to do internal con...
How to Wire Solar Panels in Series / connection/diagram /animation
• How to Wire Solar Pane...
Automatic Changeover Switch for inverter/ Automatic Transfer Switch/(ATS)
• Automatic Changeover S...
free energy dual solar , wind turbine hybrid system/renewable system /free electricity
• free energy dual sola...
Fridge Wiring Diagram / Refrigerator wiring in Hindi /How to do fridge
wiring/connection
• Fridge Wiring Diagram ...
How To do Wiring of Table Fan/Wall Fan Capacitor Connection/Capacitor
Connection
• How To do Wiring of Ta...
DOL starter wiring connection for single phase motor in stripped machine
• DOL starter wiring con...
3 PHASE DOL STARTER CONNECTION DIAGRAM /WIRING ANIMATION
• 3 PHASE DOL STARTER CO...
MIXER GRINDER WIRING CONNECTION/ANIMATION /WIRING/ VIDEO/DIAGRAM AT HOME
• MIXER GRINDER WIRING C...
SOLAR PANEL COMPLETE HOUSE CONNECTION /WIRING/DIAGRAM
• SOLAR PANEL COMPLETE H...
~-~~-~~~-~~-~
Please watch: "HOW TO DO SIMPLE COMPLETE HOUSE WIRING//CONNECTION//DIAGRAM//VIDEO"
• HOW TO DO SIMPLE COMPL...
Keyword
8 solar panel connection in series vs parallel
#solarpanel
#solarpanels
#parallel
#solarpower
#diysolar
#solar
#solarseriesconnection
#solarpanelparallel connection
#seriesconnectin
#parallelconnection
#solarpanelwiring
#solarpanelconnectionseriesorparallel
#solarpanelseriesconnection
#solarpanelconnection
#seriesandparallelcircuits
#solarenergy
#offgridsolar
#howtoconnectsolarpanels
#solarpanelconnectioninparalleldiy solarsolar powersolar series connectionsolar panel parallel connectionsolar panel wiringsolar panel connection series or parallelsolar panel series connectionseries and parallel circuitssolar energyoff grid solarhow to connect solar panelssolar panel connection in parallelsolar panels for home

Пікірлер: 29

  • @Aimsport-video
    @Aimsport-videoАй бұрын

    Are those two different 12VDC systems or can you parallel join?

  • @rajumakwana1335
    @rajumakwana1335 Жыл бұрын

    Can we charge lifpo4 wich has 4s 3.2v = 14. V 80 ah battery ?

  • @sogutlu115
    @sogutlu1155 ай бұрын

    Ben bunun aynisini yapacağım ama regülatör invertor icinde olur mu? 24 volt 200 amper Lifepo4 akü şarj olacak. 1000+1000 güneş panelini

  • @d.master.pp.master.d7201
    @d.master.pp.master.d720113 күн бұрын

    I try this setup and i used different controller and different variant of panels .. my solar setup loke this is.good.proper wire sizing and DC breaker

  • @kalutecpowersolutions9523

    @kalutecpowersolutions9523

    12 күн бұрын

    Thanks for sharing

  • @brettjeffery8160
    @brettjeffery8160Ай бұрын

    Can it work on a different watts panel like 250watt 4 on a different charge controller and 180watt different charge controller let me let know if it’s okay to connect

  • @brightogbeide6133
    @brightogbeide61332 ай бұрын

    Can I connect solar charger and normal battery charger both the on the battery?

  • @kakangprabu1700
    @kakangprabu17007 ай бұрын

    Can one solar panel be paralleled with two PCs and two separate batteries, not paralleled too?

  • @oshtechsolarsystems
    @oshtechsolarsystems3 ай бұрын

    Non Hybrid Inverter parallel connection

  • @ZIVUGAENTERTAINMENT12
    @ZIVUGAENTERTAINMENT128 ай бұрын

    Tell us the size of charge controller?

  • @crownedangel
    @crownedangel Жыл бұрын

    Shouldn't the 12v inverter be connected to the load side of the scc? How will the scc cut off the load from the battery if it's connected directly to it? Low voltage disconnect and reconnect will seem pointless.

  • @nasjude668

    @nasjude668

    8 ай бұрын

    The inverter itself has the ability to disconnect the load when battery voltage drops so there is no need to connect it directly to the charge controller

  • @ZIVUGAENTERTAINMENT12
    @ZIVUGAENTERTAINMENT128 ай бұрын

    Is this mean that 100ah battery must go with 150watt of solar panels?

  • @ZonaJim

    @ZonaJim

    8 ай бұрын

    A typical 100 watt solar panel will yield approximately 30aH of recharge per day. In order to yield approximately 100aH, you'll need about 300 watts.

  • @ZIVUGAENTERTAINMENT12

    @ZIVUGAENTERTAINMENT12

    8 ай бұрын

    Appreciate but I also need to know what size of charge controller to go with it

  • @francisdemata1514
    @francisdemata1514Ай бұрын

    Good day sir what's the name of that gadget beeing connected between the scc and batteries?

  • @kalutecpowersolutions9523

    @kalutecpowersolutions9523

    Ай бұрын

    IT IS A BUSBAR CONNECTORS, FOR MUILTIPLE CONNECTIONS

  • @mutagokharises6615
    @mutagokharises66152 ай бұрын

    Connect the battery first to charge controller dude

  • @robert4027
    @robert402710 ай бұрын

    Do the controllers need to be identical. ?? Or can they be different size in voltage

  • @ZonaJim

    @ZonaJim

    8 ай бұрын

    They can be different sizes. You can run multiple controllers into a battery bank and they don't need to be matched.

  • @robert4027

    @robert4027

    8 ай бұрын

    @@ZonaJim awesome thanks very much

  • @superfun2175

    @superfun2175

    6 ай бұрын

    Can the controller be connected to each battery and then connect the inverter to both batteries?

  • @ZonaJim

    @ZonaJim

    6 ай бұрын

    @@superfun2175 Are your batteries in parallel? If so, connecting a controller to one battery and connecting a controller to the other battery is the same as connecting two controllers to either of the batteries. Since they are in parallel, it doesn't matter where you place them. Think of the two batteries in parallel as one large battery. You can connect the inverter to either battery if they are in parallel.

  • @superfun2175

    @superfun2175

    6 ай бұрын

    @@ZonaJim yes the batteries are connected parallel, since the pwm controller produce 60A and it is 2 so am thinking maybe I can connect it independently so they receive 60Amps each then connect both ends as a whole to inverter. I hope it works

  • @pechaverj
    @pechaverj6 ай бұрын

    No, you don't connect your inverter to your load on your charge controller. Load on the charge controller is only for low amp DC like light's. Not a inverter that can pull 100 amps plus. You will destroy the charge controller. Why do people do that. I see it all the time. Even fused. 40 amp CC or 20 amp CC and so on isn't design high amps run through the load. It's for lights.

  • @weresheep9045

    @weresheep9045

    4 ай бұрын

    He didn't, he connected it in parallel with the batteries.

  • @weresheep9045

    @weresheep9045

    4 ай бұрын

    Oh, maybe this is a reply to @crownedangel's comment asking whether he should connect the inverter to the load terminals of SCC, in that case you're right.

  • @ZonaJim
    @ZonaJim8 ай бұрын

    There are so many errors with this drawing. 1. No fuses or circuit breakers are shown. That is a potential safety issue. 2. You have lines going to mysterious "12V DC Systems". The 12V DC systems should be connected to the battery if you want power when the sun is not shining on the panels. 3. You do not give specs on the MPPT controller sizes, wire sizes, Inverter sizing, etc. 4. If connecting the inverter output to the house, it needs to be connected to an isolator to prevent voltage feeding back into the grid in a power outage. 5. The inverter needs to be grounded.

  • @deejay5676
    @deejay5676 Жыл бұрын

    Very bad! Connect the modules in series and use an mppt controller. No pwm controller as shown here.