Single Phase Direct Online Starter DOL Adding Remote Stop Start Buttons Wiring Diagram Explained

Electricians Matt and Joe look at the wiring and connection in a single phase direct online started (DOL) so that you can add remote stop start buttons. In this video we explains how to connects within in a DOL starter and how to alter them to add a remote stop start button and then additional stop buttons. Matt also explains overload connection 95, 96, 97 and 98 and adds a remote indicator lamp that will light up when the motor overload operates. This wiring diagram will help with level 3 electrical courses for both electrical apprentices, part time, full time learners as well as AM2, AM2S and AM2E.
= 🕐 Time Stamps - Cut to the action 🕕 ==
00:00 - Adding a remote stop start
00:05 - Previously we looked at wiring a DOL
00:32 - Other stop start buttons
01:01 - You can have a remote stop on its own
01:25 - Remove this link
01:57 - Start buttons in parallel
02:48 - Add a link to the stop button
04:09 - Adding more stop buttons
05:16 - Mystery contacts 97 and 98
05:44 - Adding an indicator lamp
06:42 - Connections 95, 96, 97 and 98 in the overload explained
Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E.
You can follow me day by day on Facebook, Instagram, Twitter and TikTok lookout for "GSH Electrical”.
▶️ FACEBOOK / gshelectrical
▶️ INSTAGRAM / brihzmraygdtmjmdb9lunq...
▶️ TWITTER / gsh_electrical
▶️ TikTok vm.tiktok.com/ZMRBLFdhe/
#GSHElectrical #Electricaltrainingvideos #wiringdiagram

Пікірлер: 46

  • @GSHElectrical
    @GSHElectrical Жыл бұрын

    Single Phase Direct Online Starter DOL Wiring - Connections Explained and Setting the Overload kzread.info/dash/bejne/gn2V0898qLGfe7g.html

  • @golfcheznous
    @golfcheznous2 ай бұрын

    VERY COMPLETE VIDEO with enough banter back and forth to cover most questions and help even the most novice of handymen wire up a motor. Thanks for helping people around the world!! Your videos are superbly done. A request in the future...add into this an outdoor mechanical timer for scheduled irrigation.

  • @GSHElectrical

    @GSHElectrical

    2 ай бұрын

    Thanks for the great comment and watching 👍🏻

  • @shiamjad
    @shiamjad Жыл бұрын

    I could ever understand how DOL single phase and 3 Phase motors work before watching your videos.....THANK YOU VERY MUCH

  • @jollyfinequality9865
    @jollyfinequality98652 жыл бұрын

    Absolutly love this. A good refresher for me and gives me the ability to describe to my apprentices (I now have two of them) in much greater detail thanI can myself. Thank you to Jo, Gaz & TEam

  • @GSHElectrical

    @GSHElectrical

    2 жыл бұрын

    Thanks for the great comment and watching. Gaz 👍🏻

  • @drippymodz2965

    @drippymodz2965

    2 жыл бұрын

    F

  • @EJohnson-vu6pz
    @EJohnson-vu6pz Жыл бұрын

    This is a fantastic video! Very informative, explained in layman’s terms that anyone can understand. Great job guys!

  • @randonnaidoo2592
    @randonnaidoo2592 Жыл бұрын

    Please 😊 do more on how to use contractors in un-conventional ways, really enjoyed this

  • @Dog-whisperer7494
    @Dog-whisperer74942 жыл бұрын

    Very interesting. Fantastic video guy’s as always 👍👍👍👍⚡️❤️

  • @samanadam2442
    @samanadam2442 Жыл бұрын

    Thanks great video again ❤

  • @MrYoubeentrolled
    @MrYoubeentrolled2 жыл бұрын

    Matt is the real MVP

  • @GSHElectrical

    @GSHElectrical

    2 жыл бұрын

    100% agree

  • @darkdepth1991
    @darkdepth19912 жыл бұрын

    Very nice board drawing ! Keep up the amazing work teachers !

  • @GSHElectrical

    @GSHElectrical

    2 жыл бұрын

    Thanks for watching and commenting 👍🏻

  • @democracyforall

    @democracyforall

    2 жыл бұрын

    @@GSHElectrical 4 motors connected to different tables doing different jobs are all stop by a remote green stop button but a 1500 watts motor the fifth one is not connect, what to do? This big power motor has no remote stop button at all and the customer wants to connect to the existing stop button.

  • @irisylvasvea2698
    @irisylvasvea26982 жыл бұрын

    Great video ...thank you very much..

  • @GSHElectrical

    @GSHElectrical

    2 жыл бұрын

    Thanks for watching 👍🏻

  • @ahadmiah672
    @ahadmiah6722 жыл бұрын

    Great video

  • @GSHElectrical

    @GSHElectrical

    2 жыл бұрын

    Thanks 👍🏻

  • @realdondee
    @realdondee2 жыл бұрын

    Good explanation

  • @GSHElectrical

    @GSHElectrical

    2 жыл бұрын

    👍🏻

  • @kartikgautam6696
    @kartikgautam66962 жыл бұрын

    Please add selector switch & emergency switch wiring with this.. And I love your videos. Love from #INDIA ❤🙏🙏😊

  • @GSHElectrical

    @GSHElectrical

    2 жыл бұрын

    👍🏻

  • @joshuamills1392
    @joshuamills13922 жыл бұрын

    Hi guys, great video! Currently doing this on my level 3, but we've got an inch with the stop/start which we're struggling with. Will you be doing a video on this?

  • @user-mb7zd5yr7i
    @user-mb7zd5yr7i3 ай бұрын

    This was a great video to watch and very informative. Only question I need an answer to is that I intend to add additional start stop switch to control my single phase 3hp dust extractor which is located about 10m away from DOL so what size of cable would I best use for this? I got the grasp of the wiring concept now after watching this, just unsure of cable size.

  • @a_l7515
    @a_l75152 жыл бұрын

    Good vid

  • @GSHElectrical

    @GSHElectrical

    2 жыл бұрын

    Thanks 👍🏻

  • @balaramjena4875
    @balaramjena48752 жыл бұрын

    ❤❤❤

  • @mysterioustruthtruth3949
    @mysterioustruthtruth39499 ай бұрын

    Can you please do the star delta and forward reverse video

  • @idreesyunis7040
    @idreesyunis7040 Жыл бұрын

    Hi. Do you have a video on how to add an inching connection

  • @teamwacknation7171
    @teamwacknation71712 жыл бұрын

    Can you please teach us how to fix change over switch

  • @bentuffin6357
    @bentuffin6357 Жыл бұрын

    Do you have a video about a double capacitor motor? I need to identify A1, A2, A3, A4, Z1,Z2, 1 and 3 and what their for

  • @emilscarlat8816
    @emilscarlat88162 жыл бұрын

    Is it possible to connect a ceiling rose or any others lamps to an intermediate switch but not to a 1 gang 2 way switch?

  • @jordanngobeni8409
    @jordanngobeni8409 Жыл бұрын

    hey which contacts do we use for remote connection.

  • @imusuallycorrect
    @imusuallycorrect2 жыл бұрын

    Just discovered your channel. What a great resource. Thank you! Is a 3 phase DOL Starter similar? I'm trying to set up a remote switch for a 3 phase extractor. Thanks

  • @GSHElectrical

    @GSHElectrical

    2 жыл бұрын

    Thanks for the great comment - checkout this playlist 👍🏻 Motors, Starters, Controls, Remote Stop Start kzread.info/head/PL2Ea5r9gxUUfv51Ld1UlNGR39rfFIExTU

  • @imusuallycorrect

    @imusuallycorrect

    2 жыл бұрын

    @@GSHElectrical thanks for the quick reply! I'm slowly going through your videos. Very clear and I like the way you ask each other questions to explain and review what the other said. Top stuff!

  • @darrenfreeman6205
    @darrenfreeman62052 жыл бұрын

    Have you done a video on emergency stop buttons?

  • @GSHElectrical

    @GSHElectrical

    2 жыл бұрын

    Single Phase Direct Online Starter DOL Adding Remote Stop Start Buttons Wiring Diagram Explained kzread.info/dash/bejne/hZynm86Nnr28c7g.html

  • @islandhopperstuart
    @islandhopperstuart2 жыл бұрын

    Joe and Matt, thanks for this. One question on something I may have missed: are the current overload contacts 95 - 98 always latching and so have to be manually reset? (If not latching then I assume the warning lamp would immediately extinguish, yes?) So, how is a reset achieved? it is cover-off and press a button or is there a time delay? I have a starter which seems to keep dropping-out in a no load situation and hence I'm trying to get to the bottom of what's happening. Thanks again to you both for the explanation.

  • @temp06j723-pmeighttq

    @temp06j723-pmeighttq

    13 күн бұрын

    Some OLR will Auto-Reset themselves but some will require Manual intervention. The auto-reset ones can be Manually reset though.

  • @temp06j723-pmeighttq

    @temp06j723-pmeighttq

    13 күн бұрын

    Bear in mind though that UNLESS an OLR Tripped on Fault, the contacts 95/96 will remain "Intact". And contact 97/98 will "Never Connect" until OLR Tripped.

  • @kodanny7587
    @kodanny75872 жыл бұрын

    how about node 14 ? why you connect a live to there. and what it that for?

  • @temp06j723-pmeighttq

    @temp06j723-pmeighttq

    13 күн бұрын

    13/14 is Normally Open (NO) Contact. It is used for Retaining the Live supply to A1 after the Green Push Button is Released after being Pressed Momentarily.

  • @davidurwin4499
    @davidurwin4499 Жыл бұрын

    Can you please help I need to send you a photo ? how to I send it to you.