Mga ka Lodi dahil maraming nag tatanong kung safe po ba mag 2 Main Breaker yan po ang tatalakayin natin ngayon salamt sa panonoud...
#Buddyfroi
#CircuitBreaker
#RubberSocket
#Porcelainsocket
#220v line to line
Paki clik sa Link d2 kung saan natin nabili...salamt
Circuit Breaker...................invle.co/clcwn7h
Music intro By No Copyright Music
Music: Roa - Underwater
Watch: • Roa - Underwater 【Offi...
Stream / Download : fanlink.to/Roa_Underwater
License: roamusic.wixsite.com/roamusic
Music Background By No Copyright Music
1.Innovation Technology background music _ Vlog Music _ Royalty Free Music By Alec Koff.
2.NO COPYRIGHT Explainer Corporate Music Copyright Free Background Music For Tutorials MUSIC4VIDEO.
3.Product background music background music for product videos product video music By Alec Koff.
4.right Music) Technology Future Bass [Future Bass Music] by MOKKA
5.NO COPYRIGHT Infomercial Music _ Promo Music No Copyright by MUSIC4VIDEO.
6.Podcast music no copyright background music for Podcast copyright free By Alec Koff.
7.NO COPYRIGHT Acoustic Guitar Background Music _ Guitar Background Music No Copyright by MUSIC4VIDEO.
Пікірлер: 599
Very informative po sir, salamat po, dami kong natutunan.😊
Salamat sir my natutunan na naman ako.
ayos IDOL completong detalye pa shout out sa next video mo idol from taguig goyena st upper bicutan
@Buddyfroi23
Жыл бұрын
Sure...cg dol sa next video pohun....ty
magling talaga si sir magpaliwanag actual napakalinaw thanks,
@Buddyfroi23
2 жыл бұрын
Hehe...ty host
Good afternoon sir. Sapanibagong tutorial merry Christmas
@Buddyfroi23
3 жыл бұрын
Same to you sir Dayao and Happy new Year..
Gud day buddyfroi.ang linaw mo talagang mag explain.madami akong natututunan.Merry Christmas sir
@Buddyfroi23
3 жыл бұрын
Salamat sir Randolfo and advance Happy new Year..
galing mo talaga sir buddy! wala kang katulad, sa mga vlogger na kapareho mo when it comee to electricity,
@Buddyfroi23
2 жыл бұрын
Salamat sir...God bless 😊
Salamat sa bago mo vlog buddyfroi may natutunan Naman ako Happy New Year
@Buddyfroi23
3 жыл бұрын
Salamat din sir Bemar..likewise and God bless..
Sir.God bless po..Ok n ok po ang explaination nyo.. na apply ko po sa work ko sa pag electrical..sir galing nyo po..👍👍👍
@Buddyfroi23
2 жыл бұрын
Salamat Lods...God bless 😊
May natutunan na naman po ako sa inyo Sir Buddyfroi...well explained... ang galing mo Sir...season's greetings sa inyo ...pa shoutout naman Sir...Godspeed
@Buddyfroi23
3 жыл бұрын
Cg po sir Danilo note ko d2..God bless
Now lang po ulit dito napasyal ,Buddy.medyo busy kasi. nice sharing ulit.
@Buddyfroi23
3 жыл бұрын
Ok lang Lods..ty
Nice sir....gets ko po explain mo hppy holidays/GOD bless sir...
@Buddyfroi23
3 жыл бұрын
Salamat sir Jay na gets nyo..God bless and Happy new Year..
Paki clik sa Link d2 kung saan natin nabili...salamt Circuit Breaker...................invle.co/clcwn7h
Salamat buddyfroi sa mga tutorials mo dami Ko natutunan. Pa shout out naman sir. Ako Ko po si Joseph Buyoc electrical technician ng Kuwait.
@Buddyfroi23
3 жыл бұрын
Salamat din sir..cg sa next video natin..ingat po kayo dyan God bless..
Salamat sir saturo mo marami akong natotonan dito God bless po
@Buddyfroi23
2 жыл бұрын
Salamat din sir and More power...
thank sir mag iingat palagi safety first 😁 dami ko na natutunan Godbless always sir
@Buddyfroi23
3 жыл бұрын
Thanks din sir kenneth and More power..
Hey friend😆🙌 Thank you so much for using a lot of my music this year!! I always appreciate it. Big love to you‼️
@Buddyfroi23
3 жыл бұрын
Thank you too my Friend..Advance happy new Year..
Thanks Buddy Froi. Stay safe with your Family.
@Buddyfroi23
3 жыл бұрын
Salamat din sir Restituto..God bless and Happy New Year...
Nice tutorial migo, merry Christmas
@Buddyfroi23
3 жыл бұрын
Salamat sir Rene ug maayong Pasko pud diha Migo..
Buddyfroi thanks sa info and happy holiday god bless po,
@Buddyfroi23
3 жыл бұрын
Salamat din sir Arthur and Happy new Year..
Salamat master froi naa napud koi bag.ong natun.an nimo. Pa shout out usab sa next nimo nga upload master froi. Happy holiday sa imoha.
@Buddyfroi23
3 жыл бұрын
Cg Lods note nato diri ug usab..ty
Master froi, pd po mag request cable tray offset naman sa sunod mo na video. Tnx!
merry christmass sir and advance happy new year.god bless
@Buddyfroi23
3 жыл бұрын
Same to you sir Brendo..salmt
Sir buddy Froi merry xmas and happy new year po
@Buddyfroi23
3 жыл бұрын
Same to you sir Joselito..salmt
boss froi good day po. meron lang po ako lilinawin kung ano po ba magandang paraan sa pag lagay ng another outlet ng split type na aircon na safest way pero puno napo ang main breaker panel ko po sa bahay. ano po ang magandang paraan boss froi para makapag install ng another breaker for ACU for DIY lang po at saan po pwede kumuha ng supply na hinde makokompromiso ang mga line ko sa buong main breaker panel. pano po ako makapag branch ng breaker for ACU. god bless...
Sir buddy thanks happy new year
@Buddyfroi23
3 жыл бұрын
Thank you too sir Cyan..
buddy froi.. merry christmas and happy new year...
@Buddyfroi23
3 жыл бұрын
Thanks for the visit..same to you sir Doms..
Napaka husay at linaw nmn idol
@Buddyfroi23
Жыл бұрын
Salamat dol...God bless
Salamat poh...
Salamat sa shout out sir..finish jud nku imo video ..salamat sa tutorial sir..pa shout out usab sir..from Qatar.ug mga classmate naku sa ubaldo laya cla c elfred ladonga.,karen maizo, rolly andam..salamat sir. God bless you always..advanced happy new year
@Buddyfroi23
3 жыл бұрын
Cg sir Joseph note naku diri ug usab..salamt Lods..
@josephlaidaban4063
3 жыл бұрын
@@Buddyfroi23 pasensya jud sir ha..cge kog balik balik..God bless..
@josephdangalan168
3 жыл бұрын
ano po b ang equivalent ng 4,7n clamitersa30 amp
@Buddyfroi23
3 жыл бұрын
@@josephdangalan168 ang ibig sabihin doon ang Main mo sa 30amp ay may 4.7amp na nakapasok at dapat 80% lang ang gamitin mo sa 30amp..kaya 24 - 4.7=19.3amp nalang ang pwede mong gamitin sa 30amp na Breaker...Kaya lang nag 2 Main Breaker tayo kaya 19.3x2=38.6 ang pwede mong gamitin tapos ang wire dyan #10awg na may Ampacity lang na 30amp..ty
Sir very informative po. Ask ko lang po. Kung #8 ang galing sa service entrance magiging safe naba sya na maging dalawa main breaker mo. Thanks po. God bless.
@Buddyfroi23
2 жыл бұрын
Opo sir...ty
Merry Christmas ninyo diha migo ug hapoy new year sad🥰❤️❤️❤️
@Buddyfroi23
3 жыл бұрын
Same to you Migo ug sa imong Pamilya diha...Happy new Year
Bag-ong subscriber nimu sir buddy froi.
@Buddyfroi23
3 жыл бұрын
Welcome sir..salamt
@ernestojr.tomado8891
3 жыл бұрын
@@Buddyfroi23 ai, dili busy si sir master buddy froi. Electrician pud ko sir, pwo d palo tanto hanas sa pag electrical. Salamat sir sa panghatag ug pagtagad, proud bisaya. Siarganon. Pero nia sa luzon nanimpalad.
Salamat sir God bless
@Buddyfroi23
7 ай бұрын
Welcome Lods...
Master froi pwede design naman ng magnetic contactor para sa two sourch of power.para sa automatic on if the one sourch off ...the other will on automatically...thank you...
@Buddyfroi23
3 жыл бұрын
Cg sir salamat..
Salamat idol SA sharing
@Buddyfroi23
3 жыл бұрын
Salamat din Lods..
happy new year master..bagong kaibigan po..master pede pa demo in actual wiring sa pagkuha ng 230v galing sa 400v..salamat master.
@Buddyfroi23
3 жыл бұрын
Gud am sir Wenggie wala tayong Available sa 400v hanggang 230v lang tayo Lods..salmt
Galing po.
@Buddyfroi23
3 жыл бұрын
Salamat sir Allan and Happy new Year..
Pa shout ko dri. Sa legacy colege of compostela, Davao de oro. Salamat kaayo sir.
@Buddyfroi23
3 жыл бұрын
Cg sir Allan gilista na diri...salamt pud
tama idol dapat mag palit ka din ng service wire
@Buddyfroi23
Жыл бұрын
👍
Salamat sa tip buddyfroi
@Buddyfroi23
3 жыл бұрын
Salamat din sir Marlon..
Sir idol buddyfroi pwede mag demo ka ng Naka plangka na main safety switch box tapos lagyan ng mga branches na 20amp, 20amp,15 Amp na mga breaker
@Buddyfroi23
Жыл бұрын
Cg dol idea lang paki clik d2...ty kzread.info/dash/bejne/mIOowcSvhdKal5s.html
Salamat sir froi!!!
@Buddyfroi23
3 жыл бұрын
Your welcome sir Loarz..
Maraming slamat sa mga vedeo mo sir.ask lang po..kung kaya ba ng main breaker 60amp..kaya nya ba kahit may nakakabit sa kanya na 20 breaker sa panel board thanks?
@Buddyfroi23
2 жыл бұрын
Basta malaki ang wire mo sa Service wire pwede lang...ty
ganyan ang setup ng breaker ko sa house since pina extend ko ung house binukod nila ang main breaker.. pero hindi 10AWG ginamit sa mismong service line mas mataba ung wire.. so palagay ko safe naman ganyan setup basta swak ung wire ng service line! dapat inexplain mo din paano maging safe ang ganyan setup
@Buddyfroi23
3 жыл бұрын
Oo Lods nakalimutan ko palang sabihin, paano maging safe gamitin na ganyang set up..na dapat kung dalawa yong 30amp Main Breaker x2 din ang size ng service wire..salmt
Bro pwedi ka mg parallel tap sa line side basta Alam mo mg sizing ng cable @ CB
@Buddyfroi23
2 жыл бұрын
Tama po kayo sir..ty
Salamat buddy froi..bilis ng response mo.
@Buddyfroi23
3 жыл бұрын
Hahaha...hindi naman...ty
@jaygonzales2438
3 жыл бұрын
Kaya dbest pa rin yung 60amp main tas 30 tas 20 tas 15amp..branch circuit
Pa request sir, 'Paano mag compute para makuha ang Main Circuit Breaker based on load computation' Pa shout na pod sir
@Buddyfroi23
3 жыл бұрын
Gud pm sir Jun basic lang ang pag compute sa Load computation sa Main Breaker eh total mo lang lahat ang watts sa Appliances mo at sa ilaw tapos divide sa 230v yon na ang total load ampere mo sa Main Breaker..cg note ko d2...ty
@junnelouritztrazona4524
3 жыл бұрын
@@Buddyfroi23 salamat idol💖
hi sir luma pakasi breaker ung may fuse pa nakalagay sa labas 30amp 2p gusto kasana palita ng mga mcb
Shout out Bro
@Buddyfroi23
Жыл бұрын
Sure...cg Lods sa latest video....ty
Nice sharing po
@Buddyfroi23
3 жыл бұрын
Thanks for visiting Mam Divine and Happy new Year..
Sir p advise po kung ilan amperes dapat gamitin kung 2(15amps for lights) 2(20amps for outlet), 2unit acu(1.5hp/.5hp, waterpump(1hp), 1ref(9cuft) ano po kya amperes pra s main at ska po mts salamat sir
@Buddyfroi23
Жыл бұрын
Pwede na dyan sir ang 60amp na Breaker, ganon din ang MTS....ty
Shoutout po Ormoc Leyte..
@Buddyfroi23
3 жыл бұрын
Cg note ko d2 sir Gary..ty
SIR Buddy tanong ko sana po... Halimbawa po ang MAIN PANEL BOARD ko po 60A main 20A A.C.U 1hp 20A A.C.U. 0.75hp 20A C.O 1st floor 20A C.O 2nd floor 15A lightings Tapos po hiwalay po ang kusina na nakatap sa line side at may panel board at branches na 60A main 30A ref 20A C.O 15A lights Ang tanong ko po pwede po ba ilipat ko yun 60A na nasa panel boars sa kusina at ilagay sa MAIN PANEL BOARD ko po para maging 1 branch sya ng main... At kung ililipat ko po yun 60A ng kusina po Papunta sa MAIN PANEL BOARD... magtataas na po ba ako ng main breaker sa MAIN PANEL BOARD dating 60A po?
@Buddyfroi23
2 жыл бұрын
Opo sir, palitan nyo nalang ng 80amp sa Main, kayang kaya na yon...ty
Gudday SIR! ask ko lang balak ko bumili WELDING MACHINE pang gamit bahay... kailangan pa ba na naka hiwalay/ meron sariling CIRCUIT breaker or puwede na lang isaksak sa OUTLET? at pangalawa sir na tanong .. ang REF at FREEZER pwede ba magkasama sa Isang BRANCH CB? at anong AMPERE kaya SIR... salamat
@Buddyfroi23
Жыл бұрын
1.Dapat may sariling Breaker ang Welding machine para safe gamitin.. 2.Pwede lang isama Lods...20amp na Breaker...ty
Sir buddyfroi ..ask ko lang paano ba malaman,,o magcheck...ng 110-v sa tester.t.y.
@Buddyfroi23
3 жыл бұрын
Cg sir subokan mo d2 paki clik ty...kzread.info/dash/bejne/qJ2gsZpyoMeYaaQ.html
Master buddy froi pwede request naman kung paano mag gawa ng single line diagram sa isang bahay o commercial building para kung mag request ng connection para sa meralco. Ung single line diagram and computation para ma approvan ng meralco
@Buddyfroi23
3 жыл бұрын
Cg po sir Ventice note natin..salmt
Idol froi pwede ba pagsamahin ang linya ng aircon at ref? Sana po magawan ng video 😊 salamat idol froi and god bless 🙏😄
@Buddyfroi23
9 ай бұрын
Dapat naka separate talaga Lods ang Breaker sa Aircon...cg para makita paki clik d2...ty kzread.info/dash/bejne/nYlrrKuHlKu-mto.html
Sir,buddy froi sa amoa dri sa davao,tag duha lang ka linya gikan sa service intrans.unsa ba gyod ang mas safe line line o line to netral. Sa line to line ky murag tulo ka linya man gud isa ana ky ground.karon unda man gyod ang mas maayo.salamat..merry x'mass hppy new year.
@Buddyfroi23
3 жыл бұрын
Maayong adlaw diha sir Reuben mas safe jud gamiton ang line to line kumpara sa line to Neutral..Sa Line to line 110v to 110v lang kung ma kuryentehan pwede ra makalikay dayun, Pero sa line to Neutral dako kau ang isa ka linya sa Kuryente 300v+ unya kung makuryente ka ikaw ang himo-ong suka sa kuryente kay ikaw ang ground sa isa ka linya busa pwede kang madisgrasya dayon..salamt
Boss proi kung lakihan ko Ang linya ng service drop pari akin ginawa ko #8 wire mag iinit kaya Ang linya ko gdling service drop Pakisagot po Sana as soon as possible Ty po at gud day
@Buddyfroi23
11 ай бұрын
Pwedeng-pwede na Lods kung #8....ty
Sir, unsay affordable nga brand sa clamp meter imong ma recommend, kana unta naay MIN-MAX. Dili ko electrician, Sir. Nagka interes lang tungod aning sige tan aw ug KZread. Salamat.
@Buddyfroi23
Жыл бұрын
Cg Lods, idea lang paki lantaw lang sa diri sa Link video kung unsaon pag gamit sa clamp meter....ty kzread.info/dash/bejne/gmeZ07p-j8qpn84.html
BuddyFroi, ask ko lng po kung paano mag palit ng wire service entrance? Mag upgrade po kc ako ng breaker from 30A to 60A residential, need pa po ba ipaalam kay Meralco?
@Buddyfroi23
3 жыл бұрын
Tama po kayo sir ipag bigay alam nyo talaga para walang Gulo..Para may idea po kayo paki clik d2 salamt...kzread.info/dash/bejne/f3ielq6ElabKgdI.html
Good morning sir buddy froi, ok lang ba ang main breaker ko ay, CB at mag branch ako ng MCB at RCCB at RCBO?? Salamat sa sagot mo sir. Baguhan lang ako sir. Thanks.
@Buddyfroi23
Жыл бұрын
Ok lang Lods...😊
Sir Froi tanong ko lang, sir fwede bang lagyan nang submeter sa baba nang 30 ampere, tas nasa taas nang dalawang 20 at 15 breaker??? Nakikishare lang kasi kami nang kiryente, gusto ko kasi sir may 2 breaker kami, fwede lang ba yun sir Froi??? SALAMAT GODBLESS
@Buddyfroi23
3 жыл бұрын
Gud pm sir hindi po pwede na maki attach kayo sa kabilang Meter baka kasi ma over load ang service wire na tinap nyo, naka design lang yon sa 30amp.. Except kung malaki ang service wire na ginagamit sa Service Entrance...ty
Good day sir itatanung ko lang po kung pwedi po bang may kanya kanyang sariling breaker ang ilaw at outlet sa boung bahay..?salamat po.
@Buddyfroi23
3 жыл бұрын
Yon po ang tama sir dapat may kanya-kanyang Branch ang ilaw at outlet para safe..Para may idea po kayo paki clik d2 salamat...kzread.info/dash/bejne/noyjpZiplJvIgbw.html
Maayong adlaw sir froi, ask lng unta q kng pilay ampacity sa pdx wire? God bless...
@Buddyfroi23
3 жыл бұрын
Depende sa size wire sir..Kung #14awg 15amp lang ang ampacity kung #12awg 20amp unya ang #10awg 30amp...ty
@holysinnertv3518
3 жыл бұрын
Tnx kaau sir froi...
Sir Froi ask lang po, sabi nyo po kasi #10 AWG ang gagamitin galing sa servince entrance po, kapag THHN po ang gagamitin anong # po dapat? salamat sa sagot sir Froi
@Buddyfroi23
2 жыл бұрын
Ganon parin Lods #10awg o kaya 5.5mm2 thhn, pareho lang ang size wire nyan Lods...ty
master froi may tanong lng po ako, fuse box pa rin kc kmi which is 30amp, tas mag da dagdag pa kmi ng 1hp aircon, tanong anong pedeng gawin since d ko nmn pede baguhin ang wirings ng bahay, 30amp po daw pla ung mggng breaker ng ac. lam ko mgging over power ung fuse nmn, ano kya pede nmn gawin, or dyan po sa demo nyo san po ba dapt i tap ung may 500watts na ilaw. thanks sa tulong master!
@Buddyfroi23
3 жыл бұрын
Ito nalang ang gawin nyo sir para safety mag Branch po kaayo sa ilaw ng 15amp Breaker doon nyo eh tapping ang 500w na ilaw tapos 20amp para sa outlet existing mo sa aircon 15amp Breaker din..ty
Sir ask kolang po kung pano mag wirings ng first floor to second floor at ask kolang din po kung saan itatap yung main breaker ng forst floor to second floor naguguluhan lang po kasi sko thank you❤ sana mapansin
@Buddyfroi23
6 ай бұрын
Mas madali Lodz kung sa 1st floor mo ilagay ang Main Panel Board...tapos sempre may distribution wire ka sa ilaw at outlet patungo sa 1st floor to 2nd floor...ty
Paano po Kong 6AWG Ang ginamit sa service instance dyan sa dalwang tig 30 Amper yan dn mismo Ang set up ng breaker
@Buddyfroi23
Жыл бұрын
Kung #6 ang ginamit na wire sa service entrance...Pwedeng-pwede...ty
Sir gud pm po. Tanong ko lang po. Halimbawa po ay 100 amperahe ang main breaker ko, pwedi po bang gamitin ang #60 awg na wire palabas papuntang linya ng poste?
@Buddyfroi23
3 жыл бұрын
Hindi po yon sir ang Match sa 100amp na Breaker dapat #4THHN to #2..kasi ang #6THHN hanggang 75amp lang..ty
sir buddy froi itatanong kpo kung tama o hinde ang ginawa kpong diy. ang main wire kpo ay #8 thhn at ang wir kpo sa outlet ay #12 sa ilaw nman ay #14 kaso po ang ginawa kpong main breaker ay #30ampere lang at #20ampere at #15 sa outlet at ilaw ang mga gamit kpo sa bahay at tv ,ref.,electric fan, plantsa.ano po ang maipapayo nu patungkol sa ginawa kung diy .slamat po
@Buddyfroi23
Жыл бұрын
Wala akong maipapayo sayo Lods, dahil tama naman ang wiring at Breaker nyo...Ang advantage lang doon yong Main wire nyo kasi pwede kayong mag update sa 50 to 60amp na Main Breaker...ty
Pano po ba ang maganda kung magdadag pa ako ng main breaker? Salamat po, more power po sa inyo
@Buddyfroi23
2 жыл бұрын
Pwede nyong gayahin dyan sir..Pero dapat malaki ang wire nyo sa Service Entrance..ty
Buddyfroi paano ba kukuha ng source mula ground floor patungong second to third floor.
@Buddyfroi23
2 жыл бұрын
Idea lang Lods paki clik d2...ty kzread.info/dash/bejne/aYKA1LGMiryvobA.html
pwede poba kami gumagmit ng isang safety circuit breaker 40A para sa dalawang 1.5 horsepower na aircon? or pwede din 30A? sana po mapansin salamat po
@Buddyfroi23
Жыл бұрын
Pwede naman Lods...Pero mas safe kung naka hiwalay ang aircon sa bawat Breaker na 20amp....ty
Sir tanong ko lang po sana kung pwede po ba ako magtap sa service entrance o entrada.bale may sarili syang breaker at magtatap ako ng panibagong breaker para sa aircon ko?safe po kaya ito.salamat po naka follow napo ako.
@Buddyfroi23
3 ай бұрын
Pwede lang Lodz basta may kalakihan yong service wire...
Lodi, kumusta, pwede ba mag branch ng line to neutral 30 amp cb to 1 pair 20 amp cb para sa 1-1 hp water pump at 2-1/2 hp na motor para sa lechon griller. Kaya ba #10 galing sa 30A cb at #14 sa tig 20A cb bali jumper. Salamat
@Buddyfroi23
Жыл бұрын
Kaya lang Lods...Pero yong #14 eh #12 nyo yon kasi naka 20amp ang Breaker....ty
@ardacsdacs4481
Жыл бұрын
@@Buddyfroi23 Salamat sa pagreply. Helpful.
Kung e top na lang po sa no 8 service wire Iyong dalawang 30 amps breaker na main breaker ok kaya sir Iyon? Salamat sir.
@Buddyfroi23
Жыл бұрын
Ok lang Lods kung #8 thhn ang wire 😊
boss pwedi bah gamitin pang service entrance yung #10 gauge sa 60 amps na breaker ,.pang bahay poh. tnx
@Buddyfroi23
2 жыл бұрын
Naku! Boss hindi pwede yong #10 gauge sa 60amp...dapat #6...cg dagx2 idea paki clik d2...ty kzread.info/dash/bejne/amWH1tpuibTKctY.html
Sir,froi pwede bang kumuha ng supply sa Junction box para sa cb ng refrigerator?Ang main cb ay 30amp.,tapos pwede ba 30amp.din para sa refrigerator?refrigerator
@Buddyfroi23
7 ай бұрын
Hindi yon safe Lods...dapat sa Main Breaker kayo kumuha ng supply para sa bagong Breaker sa ref...pwede na ang 20amp na Breaker....ty
@jickribo7555
7 ай бұрын
Kung hindi ko nalang lagyan ng breaker para sa ref.mag splice nalang akon sa Junction box para sa outlet ng ref.total konti lang ang load ng bahay,tatlong ilaw at dalawang outlet lang ok ba Sir froi?
@Buddyfroi23
7 ай бұрын
@@jickribo7555 Kung yan lang Lods...pwede lang....
Sir buddyFroi sana po mapansin🥺 nyo, gusto k po malaman yun tamang sgot napaka very Informative nyo kasi mag explain, ang tnong ko po sa bahay kasi nmin isang breaker lang 30ampre don po s bahy nmin is 8lights , 6outlet2gang, tpos ang appliances namin 1 ref, electricfan, tv , microwave. Saan po ba ako mag ttap ng wire para s aircon maglalagy kasi ako kkyanin pb pag sinma ko sya sa 30amp c.breaker pero meron sya bukod n 20amper n cb o ggyahin k po yun vdeo nyo mag ttap ako s service line ng main breaker nmin? Tapos ano wire o size po yun ggmitin k kung ktulad s service line ng s vdeo tpos pag dting. Nmn s ppunta aircon ano wire ulit. Salamat po sana msagot mo.
@Buddyfroi23
2 жыл бұрын
Kaya pa yan sir, lagyan nyo nalang ng Branch para safe..15amp para sa ilaw at 20amp para sa outlet, kung 1hp pababa ang aircon nyo pwede lang mag 15amp Breaker...ty
@christiandiorsantos1010
2 жыл бұрын
@@Buddyfroi23 bali yung connection po kasi sir lahat ng lights at outlet bli buong bahay namin ay nasa isang 30 ampere Circuitbreaker lng kaya hindi sya maisseperate eh bali yun tanong k pde k pab sya isama doon maliit lang po ung aircon ko, .05Hp lang. Pero pg tinap ko ba don sa switch on ng 30ampere c.breaker ng bahy nmin tpos meron 20ampere circuit breaker pde pb?
@Buddyfroi23
2 жыл бұрын
@@christiandiorsantos1010 Pwedeng-pwede sir...😊
@christiandiorsantos1010
2 жыл бұрын
@@Buddyfroi23 last question po sir froi what if lagyan k ng submeter pde pb? Bali gnito yun gusto k mangyari 30amper circuit breaker nmin sa bahy dba po tpos don sa switch on k ittpat lineside at neutral sa loadside yun line1 and neuter. Ppunta aircon 20ampere circuit breaker? Tama pob at pde b? Idea ko?
@Buddyfroi23
2 жыл бұрын
@@christiandiorsantos1010 Kung mag lalagay po kayo ng Sub meter dapat ipagbigay alam nyo muna sa MERALCO..yong sa 20amp Breaker dapat sa load side nyo eh tapping sir, wag sa Line side, live tapping po kayo doon...ty
Shout-out kay danilo Dela cruz of sta Rosa laguna
Sir buddyfroi unsay asesment nimus imung power saver nga gigamit, so far unsay review nimu ato sir para naa me idea pud sir kun maayo ba gamiton or dili, salamat sir buddyfroi ...
@Buddyfroi23
Жыл бұрын
Mas maayo lang to Lods, gamiton kung sa ref ug aircon kay makatabang to sa starting current sa cg ug spike kay naaman may thermostat ang ref ug Aircon...ty
@thegoodguys2116
Жыл бұрын
@@Buddyfroi23 maayo pa imu power saver sir? Dili rato dali maguba mga ingon anang klaseha sir? Kay mamalit sad me ana sir, maayo nlng maka save pud me sa kurente gamay, salamat sir buddyfroi sa info
@Buddyfroi23
Жыл бұрын
@@thegoodguys2116 So far so good, gigamit jud naku PAREKOY hangtud karn ang energy saver sa aircon naku gigamit...God bless 😀
sir, pwede ba #6 awg ang gamitin sa service line tapos 2 main breaker tig 30A bawat isa? ty
@Buddyfroi23
Ай бұрын
Pwedeng-pwede Lodz...kahit #8awg thhn na wire....ty
Nice one dol... pa shawt awt ko baddyfroi... Llewellyn Ala of tagum city davao del norte... lalaki ko sir huh 😅
@Buddyfroi23
3 жыл бұрын
Sowe sir Liewellyn abi naku girl ba hehe..cg note na diri Lods..ty
@llewellynala6807
3 жыл бұрын
@@Buddyfroi23 lods pwede mangayo sa imohang messenger nimo para direct ko maka ask sa imoha? Tnx in advance
Sir, yong nakikita ko sa mga naunang bahay gamit nila breaker noon yong fuse type na dalawa.. tanong ko lang, pwede Po ba palitan ng 30amp breaker yong old na fuse type.
@Buddyfroi23
Жыл бұрын
Pwedeng-pwede Lods...cg para makita nyo kung paano palitan ang fuse sa Breaker paki clik sa Link d2....ty kzread.info/dash/bejne/mIOowcSvhdKal5s.html
hello po sir, inquire kulang kung anung size ng wire ang pweding gamitin sa main service kung gagamit po ng tatlung MCB panel na meron main 30amps breaker bawat isang panel. kasi po yung bahay namin hinati hati ang mga kwarto. salamat po.
@Buddyfroi23
2 ай бұрын
#6awg or #8awg thhn (optional)...ty
@romeonavasca4600
2 ай бұрын
Sir, itatanung kulang din po kung ang AWG at THHN na electrical wire ay pareho? Salamat po.
Safe ho ba yung ginawa ng electrician sa amin Bahay Main breaker 50 amp #8 yung wire service entrance.... Branches 20amp outlet, 20amp ref, 20amp AC, 15amp lightings...total branches 75amp...
@Buddyfroi23
Жыл бұрын
Safe parin Lods....ty
@BonjoVee6161
Жыл бұрын
@@Buddyfroi23 thank you lods
sir buddy froi pareho lang ba yan sa nag bridge doon nag tap sa service entrance? matawag ba rin yan na double breaker?
@Buddyfroi23
7 ай бұрын
Opo Lods...
Pero kung maliit lng nman po load ok lng cguro
@Buddyfroi23
2 жыл бұрын
Opo sir....ty
boss.. gumamit ng 60 amps single breaker.. may 8soc, 5 ilaw, ref, washing, water pump.. gumamit ng 3.5mm para sa linya socket at ilaw..thhn.. ano advice mo boss?
@Buddyfroi23
3 жыл бұрын
Hindi safe sir kung ganyan kalaki na rating na 60amp Breaker na nag iisa dapat may Branch para safe yong wire at ang Appliances..15amp Breaker para sa ilaw at 20amp para sa outlet..ty
@ShekimZ
3 жыл бұрын
@@Buddyfroi23 ok boss so mag branch nalang ako ng 20 para sa soc at 15 para sa ilaw
Paano sir if main 60amp at may dalawang branch na 60amp at 30amp? Bale gagawin ko lasing parang safety breaker yung unang 60amp tapos yung branch na 60amp is may another branch na 20amp 15amp para sa loob Ng Bahay. Tapos yung pangalawang branch is yung 30amp lagay ko Kasi sa labas para sana Incase need gumamit Ng welding or power tools. Bale Ang litaw po Nyan ganito. 60amp - 30amp. -60amp -outlet -20amp outlet -20amp aircon -20amp 0.5hp jetpump -15amp lights
@Buddyfroi23
2 жыл бұрын
Ok lang sir, basta naka Branch lang sa load side lahat...ty
Tanong lang po..sir nagdagdag po tatay ko na extension na kusina sa bahay malapit sa may entrance service..malayo po yung new kusina sa main panel board sa loob..mas malapit po if sa may connection sa labas ng service intrance magtap. Anyway nasa kalsada pa naman yung meter namin kaya papasok pa rin kunsomo sa kuntador...pwede po ba doon nalang magtap at gumawa ng new Main breaker/panel board?bale nakadrop wire ang pwede pagkabitan..galing kasi sa kalsada(kuntador) papasok sa slab ng bahay eh drop wires ang ginamit..then yung abang sa slab ay 8 size ng wire.
@Buddyfroi23
3 жыл бұрын
Pwede rin yon sir sa service wire nalang kayo mag tapping sa bagong extension sa kusena pero dapat may kalakihan din yong service wire nyo kasi mag dag-dag kayo ng bagong Panel Board..ty
@sanjoeamaranto1044
3 жыл бұрын
Salamat po...marami po ako natutunan sa inyo.
Tanong idol, tama ba yun 3 unit aircon split type 1hp inverter ay 60amp ang gamit at size 10 pdx wire ang gamit. At bawat unit my tig iisang 20amp na Breacker. Sa 60amp para lng yun sa 3 unit aircon split type 1hp at inverter clang tatlo. At di ksama dun mga outlet at mga ilaw sa 60amp Breacker. Pls sa sagot mo Salamat idol.
@Buddyfroi23
3 жыл бұрын
Sir sa ganon na set-up mas lalong safe...hehe...ty
sir froi pwede po bang mag gawa ng breaker ulit sa 30amp para sa aircon? ilan dapat na amp sa bagong breaker para sa saksakan lang ng aircon
@Buddyfroi23
2 жыл бұрын
Pwede lang sir, kung 1hp lang ang aircon pwede na ang 15amp na Breaker tapos #12 ang wire...ty
pwede bang remedyo na pagsamahin yung dalawang kable ng #10 na wire sa isang pole ng circuit breaker,pagkatapos mag-abang ng bagong dalawang#10 na kable na pinagsama magmula sa sevice drop papunta na ngayon sa ibang pole ng circuit breaker.parang dalawa na ang service cable-bali apat na#10 na kable ang nagamit,tigdadalawa bawat linya.ok ba ito sir?
@Buddyfroi23
2 жыл бұрын
Ok lang po sir...ty
@diy-all3952
2 жыл бұрын
@@Buddyfroi23 ty
Sir Buddyfroi, mag connect po kami sa main line hindi dadaan sa main breaker. Ang wire #12 patungo sa bedroom. Doon maglagay ng 20A breaker na may built-in AC outlet. 0.5hp ang AC. Safe po ba ito? Complied ba dito ang PEC? Salamat po
@Buddyfroi23
Жыл бұрын
Pwede lang sir, basta tama yong size rating sa Breaker....ty
@eugeniogozon7440
Жыл бұрын
@@Buddyfroi23 Sir, ganito ang final na nangyari. Ang 0.5hp na non-inverter aircon doon kinabit sa 15A breaker ng ilaw na may total 85 watts ng LED bulbs. Sana safe pa rin ba ito? Salamat po.
@Buddyfroi23
Жыл бұрын
@@eugeniogozon7440 Safe parin naman, kaya lang mas safe kung naka separate talaga sa ibang Breaker ang aircon...kasi pag nagloko ang aircon malamang wala narin kayong ilaw kasi trip ang Breaker hehe...ty
Sir Buddy froin, tanong ko lang po gusto kp sana subukang ayusin wiring ng ilaw, safe nakaya mga wires kung off ko breaker?
@Buddyfroi23
Жыл бұрын
Opo Lods...basta sa Main Breaker, wag yong Branch para safe...ty
Good noon sir buddy...ok lang po na mag two branches Ako at 30 amp Ang gamit ko,kahit nka sub meter Ako?
@Buddyfroi23
Жыл бұрын
Pwede lang Lods...
Sir buddy froi sa Bahay Po Namin fuse box na 20amp..pwd bang mag top Ng single breaker sa pinaka lineside tas lalagyan ko pa Ng sub meter at anung tamang wire pwd ba Yung ganun gawa..sana masagot ito pra may idea Ako tyaka line to neutral Ang suply safe Kya..
@Buddyfroi23
Жыл бұрын
Depende po yan Lods sa service wire...kung naka design lang yan sa 20amp hindi ka pwedeng mag tapping sa line side para hindi ma overload....ty
@trythisvideokainpamore4085
Жыл бұрын
@@Buddyfroi23 idol Yung gamit ko lang Isang electrician tas tatlong ilaw na..tag 5wacth
@Buddyfroi23
Жыл бұрын
@@trythisvideokainpamore4085 Kung ganon lang...pwede lang 😊
@trythisvideokainpamore4085
Жыл бұрын
@@Buddyfroi23 slamat idol atlis may idea ako