No video

Roof Rain Screen with Cor-a-Vent

On his family’s 3:12 pitch roof, Corbett Lunsford installs a ventilation gap before the 24-ga standing seam roof goes on.
Learn more about the furring strips at: Cor-a-Vent.com
More about tapes and membranes at: FourSevenFive.com
More about this build at: HomeDiagnosis....

Пікірлер: 55

  • @BlackOTR1
    @BlackOTR14 жыл бұрын

    House looks like it is coming along well. Love the videos.

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    Thanks!

  • @pjnelson5827
    @pjnelson58273 жыл бұрын

    I have seen other rain screen try builds where they nailed the furring strips at a 45 degree angle to the slope. That gives up-slope airflow, and cross-slope support for steel, all in one layer. Would that have worked for this build?

  • @HomePerformance

    @HomePerformance

    3 жыл бұрын

    Here’s a vid especially for you, PJ! kzread.info/dash/bejne/i4ajrM2imLzAprA.html

  • @braydonscully4646
    @braydonscully46464 жыл бұрын

    Great progress, really looking forward to the window/door detailing with the rockwool exterior insulation. It is one detail that I can’t get my head around!

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    Thanks Braydon! Stay tuned. February.

  • @treystills
    @treystills3 жыл бұрын

    Awesome!!! Thanks for sharing, very generous

  • @HomePerformance

    @HomePerformance

    3 жыл бұрын

    Our pleasure!

  • @tinkermouse-scottrussell3738
    @tinkermouse-scottrussell37384 жыл бұрын

    Thank you kindly for your awesome job, Corbett & the HP Team looking forward to next year's content. From my family to your family, Merry Christmas and the best to you all in the New Year. Play Safe From Elliot Lake Ontario Canada.

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    Aw thanks Scott! Back atcha.

  • @howibuiltmyownhomeevenacav4944
    @howibuiltmyownhomeevenacav49444 жыл бұрын

    Thanks Corbet great alternate to the 45degree method. Just one question about the sturdi strips, how well do they hold up to the heat under a metal roof, will they soften and compress under the pressure of the screw holding the 1x4 battens? One thought .... do you think a fully threaded screw and a counter sunk hole would be better as the wood batten would not compress the sturdi strip as the screw is drawn tight to the deck.... I will be installing a metal roof on my self build and like you suffer from paralysis of analysis lol..

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    Haha, good question- this is not my first build with these Sturdi-Strips. They’re on the TinyLab roof too, and no, they’ve given us no issues with softening, shifting etc. You want a tight fit, so don’t worry about pulling the connections tight- you can’t hurt these things. The screw head would bust thru the wood before that happened.

  • @johnwhite2576
    @johnwhite25764 жыл бұрын

    Corbin-why did you choose Cora ent versus Benjamin Obydyke mesh of a dimple product (delta MS etc)

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    I had experience with Cor-a-Vent before, and knew it paired well with Mento.

  • @iwillnotcomply007
    @iwillnotcomply0074 жыл бұрын

    I don't understand the need for the sturdi strips. Wouldn't wood work as well? After all, you are attaching wood strips to the sturdi strips. Is it to get just that little extra ventilation? I understand the cora vent at the top and bottom, just not those strips running vertically.

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    It would have to be GT pressure-treated, which means chemicals potentially leaching onto the mento- want to avoid that. Plastic is tried and true for this purpose.

  • @iwillnotcomply007

    @iwillnotcomply007

    4 жыл бұрын

    @@HomePerformance what about the wood strips you are attaching to the sturdi strips? They aren't pressure treated. Is it because they have an air gap beneath them so they don't need to be?

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    Right, they won’t be sitting against a wet surface, since they’re elevated.

  • @craigcarpenter3403
    @craigcarpenter34034 жыл бұрын

    Were those 10d Commons in the strapping? Been curious about the venting details, thanks for showing your approach. I'm in an extreme high fire zone and don't think it gets mentioned enough that for people in similar high risk areas,

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    Yes, Craig, 10d 1.5”. Interesting about the fire risk- I’ve not had to ponder that.

  • @krogg5868

    @krogg5868

    Жыл бұрын

    Or you can build out of fireproof material but yes an air gap can increase fire risk.

  • @NathanielTHughes
    @NathanielTHughes4 жыл бұрын

    Great concept with vented rain screen. Curious why you didn't any exterior insulation on the roof?

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    Energy model showed no significant benefit on either energy costs or comfort control, Nathaniel

  • @NathanielTHughes

    @NathanielTHughes

    4 жыл бұрын

    @@HomePerformance makes sense 🙏

  • @cooper8318

    @cooper8318

    12 күн бұрын

    @@HomePerformance I know this is old now but do you remember what your standard roof insulation was rated at and what zone are you in? Did the fact that you did a vented rainscreen roof decrease the need for exterior roof insulation? Ive always understood the roof insulation to be more important than the walls. Sorry for the paragraph, just trying to learn as much as I can before I start my build here in zone 5

  • @HomePerformance

    @HomePerformance

    12 күн бұрын

    Zone 3/4, R-38 cavity. I ran the energy model.

  • @cooper8318

    @cooper8318

    10 күн бұрын

    @@HomePerformance Awesome. Thank you

  • @Foche_T._Schitt
    @Foche_T._Schitt4 жыл бұрын

    Matt Risinger runs the wood strips on 45's to allow air and any water to find a path out.

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    You mean in one layer, I imagine. Here the same effect is achieved. My question with Matt’s way: how do you make certain you’re hitting the joists every time, and do you use continuous butyl like this method? More material on the diagonal.

  • @steven7650

    @steven7650

    4 жыл бұрын

    @@HomePerformancedepends on the underlayment thickness. 5/8 & 3/4 is as good as hitting a stud. Also I would screw the furring strips down. Nails are for shear force, if anything in highwind those will be subjected to lifting force which is not what nails excel at.

  • @michaelvrbanac6923
    @michaelvrbanac69235 ай бұрын

    Have fun knocking on exterior board insulation to find your trusses.

  • @HomePerformance

    @HomePerformance

    5 ай бұрын

    No exterior insulation- watch the video before you get snarky bud

  • @michaelvrbanac6923

    @michaelvrbanac6923

    5 ай бұрын

    @@HomePerformance I watched it. And don't assume that I didn’t before you get sparky. You may not be using exterior insulation, but CI is becoming the norm for building codes including roofs.

  • @vennic
    @vennic4 жыл бұрын

    Could you do a self sealing demo with that tape to show us?

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    Already done! Installing Mento Airtight Roof Underlayment kzread.info/dash/bejne/moOclJqnidWpqqw.html

  • @creechmeister
    @creechmeister Жыл бұрын

    Cool product, but way cheaper to just use regular furring strips or ripped plywood to make the regular battons, and trim with the coavent sv3/sv5

  • @---sb4rp
    @---sb4rp3 жыл бұрын

    What is the spacing for the 1x4 furrowing strips, 16" on center?

  • @HomePerformance

    @HomePerformance

    3 жыл бұрын

    Yes

  • @bryanchattelle1924
    @bryanchattelle19244 жыл бұрын

    Why would you use the mentos and all the tape. Why not just use and ice and water shield product

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    Vapor permeability

  • @joshuasmith1215
    @joshuasmith12152 жыл бұрын

    use a couple magnets to find the joist

  • @joshuasmith1215

    @joshuasmith1215

    2 жыл бұрын

    or a studfinder

  • @HomePerformance

    @HomePerformance

    2 жыл бұрын

    Not every nail hits solid wood- on any crew in the world.

  • @gary24752
    @gary247529 ай бұрын

    Just use Sharkskin underlayment.

  • @sidingmaster
    @sidingmaster3 жыл бұрын

    That Screen over that plastic Cora vent will clog within a short period of time then you are not allowing airflow. Even worse the condensation will not be able to escape or the heat. Bad move. You didn’t do your research

  • @HomePerformance

    @HomePerformance

    3 жыл бұрын

    Clog from what? What research?

  • @AmandaComeauCreates
    @AmandaComeauCreates4 жыл бұрын

    Spruce 1x4 under a metal roof in a hot humid climate? Won't they rot?

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    I don’t believe so- why would they?

  • @townsendliving9750

    @townsendliving9750

    4 жыл бұрын

    When the sun hits this roof it will heat the air and bring in new fresh air. This thing will thermosyphon quite well. I'm sure one day he will be able to show a thermo image of air leaving the roof caps/vents.

  • @cooper8318

    @cooper8318

    12 күн бұрын

    He's got an air gap there. Wood only rots when it can't dry

  • @abenzuoo
    @abenzuoo4 жыл бұрын

    uses plastics :D b**** please

  • @arvin4910
    @arvin49104 жыл бұрын

    Too much waffling.. 🤪

  • @HomePerformance

    @HomePerformance

    4 жыл бұрын

    Yuk yuk