Reinforced Concrete Column Construction Process / How Is Made
In this video, you will see how to make a column in a concrete structure. Implementing the principles of the column is very important because the column transfer vertical loads from a ceiling, floor or roof slab or from a beam, to a floor or foundation .
#GroundColumn #ConstructionWorkProcess #ReinforcedConcreteConstruction #ReinforcedConcreteColumn
---------------------------------------------------------------------------------------------------------------------------
I hope you enjoy watching this video.
Do not forget to like and comment.
---------------------------------------------------------------------------------------------------------------------------
subscribe my channel :
/ ch
Пікірлер: 93
Thank you for sharing your expertise and observations. Your input is valuable for improving the construction process and ensuring structural integrity. It's always great to have knowledgeable people in the community sharing their insights.
I really like your way of making this steel, it's amazing
Well Done guy`s
great 👍
Wow nice work my guys👏👌
Perfekt 👍👍👍👍👍
I am a developer in Cambodia. I am very satisfied with the work in your country, please advise, thank you.
¡¡¡Excelente trabajo!!!!
Estos trabajadores iraníes son buenos 😊
Very good👍👍👍 👷👷👷👷
Good job thank you for video
@howismade981
2 жыл бұрын
Thank you for your comment .
brilliant work guys. well done
The rebar legs should face outside also stirrup hooks should be around 135 degrees not 90
Good job 🤝🤝🤝👍
Μπράβο παιδιά βλεπο κάνετε πολλή καλή δουλειά να είστε όλοι καλά
@thamhoang80
Жыл бұрын
Họ để sắt cột sai
last 90° bend in stirrups is an error, it can lead to failure at that point, but more important is column rebar 90°bend should radiate out, not in... in leads to too much bar in the center increasing risk of poor concrete fill
@izmirfication
Жыл бұрын
Column longitudal rebar bends facing inside at base lead to congestion and poor compaction at that zone, totally right..
@edgonzalez186
Жыл бұрын
So... how much stories can that building safely rise? There's plenitud of rebar in those columns.
@sergegostoli9524
Жыл бұрын
@@edgonzalez186 load design for a specific column it doesn't depend just on rebar, but also in concret grade C18 C25 C50 ? and work quality length vs area (buckling) not to mention ground quality (not all sil has the same load capacity) , you would need a complete blueprint of the building and a soil study to make such a determination
@angomgunindrosingh9178
Жыл бұрын
Column rebar 90 bend means development length of column in engineering term. There is rule of placing rebars in different direction to acquire the strength of materials used.
@scarabooshable
Жыл бұрын
It's all an error mate. This is going to be a five storey building.... Would you sleep in it.? No clue what they are doing. At a.
Good
Good luck 👍
I like that job I work the same thing here in the Dominican Republic
@kodyarquette1368
Жыл бұрын
Hell yeah bro! What do they call your trade down there?
@scarabooshable
Жыл бұрын
Hopefully with more engineering. These picks put lives at risk.
Here in the Dominican Republic we put the leg of the column out
Semangat boss
@Jamal50893
Жыл бұрын
জামাল
❤❤❤ Thật Tuyệt Vời ❤❤❤
nice
@scarabooshable
Жыл бұрын
Oookay. 😂
I hope you know and accept that doweling columns/zones and walls is easier on bottom steel not after top-ste
👌👌👌👌
Spacing between two bars can't be less than an inch and half; otherwise, aggravates won't pass through
@scarabooshable
Жыл бұрын
.... Least of the problem. No drawings. No calculations. No engineering. .... And apparently this building is going up five storye.!!!! Pray for the people in it when it collapses. Absolute nightmare. No clue what they are doing.
@randomcrashingfacility31
6 ай бұрын
@@scarabooshable I've never seen a building with supposedly no engineering have such big columns with this much rebar.
Salute bonsoir 🇭🇹🇭🇹🇭🇹💥💥💥💥🔥🔥 🔥 🔥✈️✈️
It would be simpler to make a complete metal building. It's 50% iron anyway
Sharing knowlegde is the best and improve together.
👍👍
i like to share video
고층 건물이 아닌 것 같은데 철근 배근양이 엄청나군. 한 10층 이상 올려도 되겠다.
@howismade981
Жыл бұрын
The building has five floors
Grave error el doblete de varilla es hacia afuera y no cumple las normas de espacio de respiro entre concreto varilla esa construcción se caerá no es flexible así como poca varilla es malo también el exceso
👍 my muslim brothers
duno why they bunched up those L bars like that.
Please I need your experience
@howismade981
Жыл бұрын
If you have any questions, ask
@matarcham7040
Жыл бұрын
I want to know more
@matarcham7040
Жыл бұрын
@@howismade981 Please I want to work with you
@howismade981
Жыл бұрын
@@matarcham7040 This project is in Iran,. Ask if you have any questions
@matarcham7040
Жыл бұрын
@@howismade981 It's so beautiful and good I want to join you guys
تركيب العامود بهذه الطريقة غلط يجب ان تكون الزاوية إلى خارج العامود وليست إلى الداخل لانها ستسبب كثافة تحت العامود وستمنع الخرسانة من التوغل تحت العامود
@scarabooshable
Жыл бұрын
It needs to be designed properly for what it it is going to support. Full stop.
What is the country?
@howismade981
2 жыл бұрын
iran
@scarabooshable
Жыл бұрын
.... Look forward to the news report when it collapses.
estoy viendo vidio doblete varillla es pa fuera es verdad el comentario a fin alcabo no soy de ese pais yo creo en mi opinion hay error como trabajan
THEY INSTALL COLUMN REBAR WRONG
Can't see a drawing anywhere so assuming they are winging it with no calculations. .... This, people, is why we see RC structures collapsing on news reports. Often killing and trapping unaware users of the building. Stop. Please, please stop. Get your buildings designed properly, and the works supervised by engineers. It literally isn't rocket science. Watching this is making me nervous.
@howismade981
Жыл бұрын
Dear friend, this building, including columns, roof, foundation and other structural elements, has been designed by software and has been approved by the municipality of the region. Of course, if a strong earthquake occurs, no structure can be said with certainty that it will resist. But if there is a specific place that is not implemented correctly and does not have enough resistance, I will be happy to mention it .
@Nick32176
4 ай бұрын
adding extra reinforcement in the columns is more worse than having not enough. because it will not give you enough time to escape during collapse. but some people think more is better, which is always not true.
A lot of mistakes made in that reinforcement, wouldnt pass my inspection
@randomcrashingfacility31
6 ай бұрын
Could you mention them please? I'd be curious to know.
Countless mistakes. binding wire should be double looped and with the right thickness of the wire. poor binding. it will break during concrete is poured. also 90 degree bend are useless on the stirrups. should be 135 degree. there is no concrete cover provided either. Over did steel enforcement. Ld other way around........
Don't see a feminist there 😋
Pésimo amarre
Terrible. wouldn't be allowed to build so poorly in Europe! This building would be torn down again immediately.
@randomcrashingfacility31
5 ай бұрын
Why?
@Uyiiouuoiuiiuyi
5 ай бұрын
😂
@Uyiiouuoiuiiuyi
5 ай бұрын
Who give a fuck about Europe
@randomvideos466
5 ай бұрын
you must learn more about construction engineering
@fetigueouatt6511
5 ай бұрын
Et pourquoi eclairez nous svp
Kolon etriyelerini kanca şeklinde 45 derece yapın kolay gelsin...
@furkancpl4933
Жыл бұрын
bilmediğimden soruyorum 2. katın kolon demirleri 1. katın yarısına kadar sarkıtılıyor dinine kadar sarkıtılsa sağlamlıkta fark yaratırmı
@ismailyasar2209
Жыл бұрын
@@furkancpl4933 videodami öyle yapıyorlar tam olarak inanın anlayamadım ne demek istediğinizi .?
@furkancpl4933
Жыл бұрын
@@ismailyasar2209genel olarak soruyorum. kolonları ek yapıyorlarya demirleri yarıya kadar indirip bağlıyorlar . Demirleri yarıya değilde diğer kolonun dibine kadar indirse sağlamlık olarak fark yaratır mı
@ismailyasar2209
Жыл бұрын
@@furkancpl4933 o şekil olmaz çünkü esneme salinim payı kalmaz demek istediğinizi gayet iyi anladım ben inşaat yüksek mühendisiyim aynı zamanda cirakliktan gelme çocuk yaşlarda çekirdekten gelmeyim...Kolon filizlerinin içine girmesi lazım donatinin yani kolonun , bu şekil deprem anında örneğin filiz 1.00 mt -1.20 MT o filizlerden esneyip salınım yapıyor sağa sola ileri geri v.s ...Demir çok önemli ve etriyeler ve dikkat edin parça L şeklinde demir atıyorlar kolon içlerine çiroz deriz ...Etriyeler L olmaz kanca şeklinde U şeklinde olsa çok daha mantıklı ve sağlıklı olur , google kancalı etriye yazın ne demek istediğimi anlayacağınızi düşünüyorum....
@scarabooshable
Жыл бұрын
No it isn't easy. What are they supporting.? None of you know what the fuck you are doing. ... Front a British formwork joiner.
How many floor going up? 20? U used so much steal looks more than enough around the building height..
@howismade981
Жыл бұрын
The building has 5 floors
@scarabooshable
Жыл бұрын
Dangerous. Very dangerous. Even for 2 floors.
@scarabooshable
Жыл бұрын
@@howismade981 You're going to kill people. Where are your drawings.? No way that will support 5 floors.
💔 ρ尺oΜ𝐎ᔕᗰ
Good