RCD | Analysis | Singly reinforced T-Beams

✅Be an exclusive member and get access to our Members-only Videos. (w/ Latest Board Exam lectures)
Click the link below to join:
kzread.info.../UC1xLs...
✅Join our community (fb group)
/ delacruzengineeringcom...
✅Facebook page:
/ delacruzengineering
✅Review books for sale:
/ shop_tab
✅Looking for Quality Civil Engineering Review and Training Center for Licensure Examination?
Enroll now at GERTC (Gillesania Engineering Review and Traning Center)
/ gillesaniareviewcenter
#CivilEngineering #CivilEngineeringReview #CivilEngineer #CEReview #Review #CELEREVIEW #DeLaCruzEngineering #HPGE #FLUIDMECHAICS #HYDROSTATIC #hydraulics #CEboardexam #PSAD #MSTHC #HPGE

Пікірлер: 20

  • @jherickconzaga154
    @jherickconzaga1548 ай бұрын

    Sir pano po kunin value ng hf po pag hindi given may ginagamit po ba na formula or may default value po sa codes?

  • @IzavelleGaza-ww7jn
    @IzavelleGaza-ww7jn Жыл бұрын

    Sir I hope you still respond, 'yung Cf and Cw po ba, hindi po ba siya pwede palitan ng T=Asfy? Medyo confused po kasi ako when to use T and C since diba same lang po sila ng value.

  • @faithanneanano9246
    @faithanneanano92469 ай бұрын

    Sir what if N.A. lies outside the flange?

  • @csereviewtambayan3113
    @csereviewtambayan31133 жыл бұрын

    Thank you sir. Sana columns naman ang susunod :D

  • @EngrDeLaCruz

    @EngrDeLaCruz

    3 жыл бұрын

    Thank you for watching! Please check upcoming tutorials :)

  • @shairaaribal1
    @shairaaribal13 жыл бұрын

    wow

  • @ryzenfurry413
    @ryzenfurry41310 ай бұрын

    Mali sir mn

  • @markjandeedizon4575
    @markjandeedizon45753 жыл бұрын

    Sir yung value ng Mn, natypo error ka ata? the second situation

  • @EngrDeLaCruz

    @EngrDeLaCruz

    3 жыл бұрын

    Paki double check nalang po, but same analysis and procedure lang.

  • @villapusa4825

    @villapusa4825

    2 жыл бұрын

    Tama typo talaga dapat Mn = 1608

  • @parengtroy5663

    @parengtroy5663

    2 жыл бұрын

    Oo nga sir dapat 1608

  • @leadellbaudillo7403
    @leadellbaudillo74033 жыл бұрын

    Sir tanong lang po, ano po pagkakaiba ng solution ng Design of T-beams and Analysis of T-beams? Maraming salamat po.

  • @EngrDeLaCruz

    @EngrDeLaCruz

    3 жыл бұрын

    Design-given loads and and design the rebars Analysis-given dimension and rebars and calculate the capacity

  • @leadellbaudillo7403

    @leadellbaudillo7403

    3 жыл бұрын

    @@EngrDeLaCruz thank you po engr!

  • @jolotuastomban4466
    @jolotuastomban44664 ай бұрын

    GOOD EVENING SIR, patolong po dkopo makuha ang Mn

  • @jolotuastomban4466

    @jolotuastomban4466

    4 ай бұрын

    i mean pano mo po nakuha ang 1459.3 KN.m??

  • @jolotuastomban4466

    @jolotuastomban4466

    4 ай бұрын

    result sakin po is 1,608,307,326.27 huhu

  • @jolotuastomban4466

    @jolotuastomban4466

    4 ай бұрын

    1608.3 KN.m lang po hehe

  • @kh4nn123

    @kh4nn123

    4 ай бұрын

    @@jolotuastomban4466 same po tayo kuya 1608.333

  • @stevethesteve2007

    @stevethesteve2007

    4 ай бұрын

    My typo erroe ata yan, 1.608E^9 yung sakin

Келесі