Power & Distribution Transformer | What are the differences | TheElectricalGuy

Difference between power transformer and distribution transformer is explained in this video. Power vs distribution transformer.
➜ Fundamentals of power system - courses.theelectricalguy.in/c...
➜ Complete guide on electrical transformer - courses.theelectricalguy.in/c...
===============================================
📌 Join me on Social Media
Facebook ➜ / iamtheelectricalguy
Instagram ➜ / the_electricalguy
Electrical courses ➜ courses.theelectricaalguy.in
===============================================
#transformer #distributiontransformer #powertransformers

Пікірлер: 34

  • @Energized_Human
    @Energized_Human3 ай бұрын

    Thank you sir For your clear cut knowledge sharing 😌

  • @GauravJ

    @GauravJ

    3 ай бұрын

    Thanks and welcome

  • @akbanchhor1499
    @akbanchhor14993 ай бұрын

    Maximum Efficiency of a Transformer, when Copper Loss(I²*R) equals to Iron losses. (We = Ke * Bm² * f²* T² * V and Wh = Kh * Bm¹'⁶ * f* V) Thank you for this video sir👍

  • @roberttshitenda7878
    @roberttshitenda78782 ай бұрын

    Good day,I like your explaination,I feel I am on field working, this is theory and practical,...

  • @muhammedsaad5952
    @muhammedsaad59523 ай бұрын

    Please make video about recatance neutral,and solid neutral and other things about neutral..❤

  • @youssofasiry7233
    @youssofasiry72333 ай бұрын

    Thanks for all details and excellent explanation. Could you please tell us when we use connection type if Delta or star on primary and secondary sides?

  • @exo-580
    @exo-5803 ай бұрын

    awesome videos,i keep watchin i keep learning😄💪

  • @rezafaraji653
    @rezafaraji6533 ай бұрын

    So so helpful

  • @transmissionlinetricks9760
    @transmissionlinetricks97603 ай бұрын

    Superb! Please make video on shunt reactor

  • @vamshikalyanapu
    @vamshikalyanapu3 ай бұрын

    Sir make a video on how the communication line frequency are effected on power transmission line frequency.

  • @JamesZhao-wl5br
    @JamesZhao-wl5br27 күн бұрын

    thanks sharing

  • @surendrakverma555
    @surendrakverma555Ай бұрын

    Thanks Sir 🙏

  • @paduprakash
    @paduprakashАй бұрын

    Likewise, please explain how different is Inverter duty transformer used in solar PV plants. Thank you.

  • @jimohchileshe7433
    @jimohchileshe74337 күн бұрын

    Kindly make a video on why power is generated at 11kv

  • @nileshamigoo3829
    @nileshamigoo382911 күн бұрын

    Please make one video about neutral grounding and grounding, neutral grounding transformer , neutral grounding resistor and neutral grounding reactor

  • @ginpubaite5087
    @ginpubaite50873 ай бұрын

    sir i need you to explain difference between ct and pt used in 132kv/33kv shuityard

  • @keyvanfiruzi3998
    @keyvanfiruzi39983 ай бұрын

    200 MVA is too much for a distribution transformer. their power ratings are usually less than 2 MVA

  • @axieindia8009

    @axieindia8009

    3 ай бұрын

    right

  • @imeprezime1285

    @imeprezime1285

    2 ай бұрын

    Any unit above 100 MVA should be considered power transformer.

  • @golamrabbi3150
    @golamrabbi31503 ай бұрын

    Please upload a series on relay & their connections.. Please Sir 🙏

  • @mohamedharoon981
    @mohamedharoon9813 ай бұрын

    Dear Sir Please explain the HVDC transmission System and the difference between HVAC and HVDC transmission system

  • @GauravJ

    @GauravJ

    3 ай бұрын

    I will try 👍

  • @vinaybabupolimera8270
    @vinaybabupolimera82703 ай бұрын

    Sir will u explain about power factor correction at 132kv/33kv substation.when capactor bank is connected to 33kv bus.

  • @shaqeelquraishi2407
    @shaqeelquraishi24073 ай бұрын

    Please make videos for learning schematic drawing wiring power wiring series please

  • @ganeshanthiyagarajan1595
    @ganeshanthiyagarajan15952 ай бұрын

    Sir pls explain about HVDC transmission system

  • @Fabinhoo0100

    @Fabinhoo0100

    Ай бұрын

    This would be really nice

  • @mdjawed8966
    @mdjawed89662 ай бұрын

    Sir Pls provide PD Measurement Vedio of GIS Substation.

  • @user-mj5wy5ei7t
    @user-mj5wy5ei7t3 ай бұрын

    My name is chernor from sierra Leone am learning a about this about power systems

  • @engr.quratulainsuhail
    @engr.quratulainsuhailАй бұрын

    Sir can't get the zero sequence positive Nd _ve sequence currents flowing plz make video on that

  • @hardikpalsanawala7913
    @hardikpalsanawala79133 ай бұрын

    What is the use of NGR for a transformer, why we can't use that in every transformer, is that related to fault clearing time??

  • @vamshikalyanapu
    @vamshikalyanapu3 ай бұрын

    Power transformers are also running at 24 hours so the copper losses and iron losses also there so what is the efficiency of power transformer?

  • @Solarified
    @SolarifiedАй бұрын

    Hello sir, Why are there no breathers in the distribution transformer?

  • @World_Knowledge9
    @World_Knowledge926 күн бұрын

    HT TRANSFORMER WINDINGS ( brief) theory please send any link

  • @Buy_YouTube_Views_a050
    @Buy_YouTube_Views_a0503 ай бұрын

    How do you always make such good videos 🔥