Pipe Line Sizing by Velocity for Gases | Simple Science

Ғылым және технология

This video explains sizing of pipe lines OR tubes used in process industries by calculating velocity of gases.
★ Flow velocity calculation for Gases
★ Recommended Gas velocity for pipe selection
★ Factors to be considered during pipe sizing

Пікірлер: 39

  • @manucenthilnathan3241
    @manucenthilnathan32413 жыл бұрын

    Great video. Have been searching for this! Thanks

  • @livingmax383
    @livingmax3833 жыл бұрын

    Very informative.. Thanks

  • @abhijeetsingh7824
    @abhijeetsingh78242 жыл бұрын

    Thank you

  • @mohsenk5985
    @mohsenk59856 ай бұрын

    Please keep making these videos

  • @harithgodz
    @harithgodz2 жыл бұрын

    Hello sir. Where did you get the recommended gas velocity? does this apply to compressed air too?

  • @Mr.DX_Official
    @Mr.DX_Official2 ай бұрын

    its a saver thanks

  • @uchechukwuekwueme3559
    @uchechukwuekwueme355910 ай бұрын

    battling with how you got 0.01184 for 1/2'' NPS Schedule 160 and 0.0207 for 1''

  • @harshchande687
    @harshchande6873 жыл бұрын

    For 3/4 NPS SCH160 , Gas velocity is 24 m/s. Therefore pipe size is also recommended.

  • @zayedaljabri5454

    @zayedaljabri5454

    2 жыл бұрын

    What is the inner diameter ?

  • @dialgang7872
    @dialgang78722 жыл бұрын

    may i know how to get 120 Nm3/hr in velocity of gas ? or it is assumption ?

  • @nawazmotiwala1989dsg
    @nawazmotiwala1989dsg10 ай бұрын

    What is 0.1 in formula, Also What is 273.15 in denominator?

  • @user-ow9de1vg8g
    @user-ow9de1vg8g2 ай бұрын

    Hello, great video but why use the minimum operating pressure?

  • @abhisheksrini9807
    @abhisheksrini9807 Жыл бұрын

    Recommended velocity less than 25 m/s? How the value is taken?

  • @AliAlias
    @AliAlias2 жыл бұрын

    Thanks very much. What about natural gas with mixture component c1, c2, c4, c5, h2s..@ high pressure for example 15~24 bar

  • @SimpleScience

    @SimpleScience

    2 жыл бұрын

    You can use same method

  • @user-cv8bz9nf5w
    @user-cv8bz9nf5w10 ай бұрын

    Gas velocity ~ 16, 3/4" is also recommended for this application

  • @praveenmanogaran5677

    @praveenmanogaran5677

    27 күн бұрын

    i got this value too, i got 15.47 m/s

  • @PremKumar-py7hm
    @PremKumar-py7hm11 ай бұрын

    How to calculate velocity of a power plant chimny by stack kit

  • @kaustubhdikshit439
    @kaustubhdikshit4392 жыл бұрын

    What about gas compressible factor

  • @gitapandya2371
    @gitapandya2371 Жыл бұрын

    What mean of cubeak gas line

  • @LeeeJim
    @LeeeJim2 жыл бұрын

    Thank you so much. But where does 273.15 and 0.1 came from?

  • @LeeeJim

    @LeeeJim

    2 жыл бұрын

    I just found 273.15 is absolute zero. What about 0.1 value sir?

  • @kbskbskbskbskbskbs

    @kbskbskbskbskbskbs

    2 жыл бұрын

    @@LeeeJim it is related to the pressure. The original formula for normal volume flow rate and actual volume flow rate is (normal means at 273.15 kelvin and approx 100 000 pascal): Q = Q0 * (Z * T * p0) / ( Z0 * T0 * p) Z and Z: are compressibility and normal compressibility, not considered in this video The 0.1 in the formula (in the video) is due to p being in MPa and to p0 not being explicitly included in the formula.

  • @joergdyckerhoff471

    @joergdyckerhoff471

    Жыл бұрын

    @@LeeeJim 1 atm. From combined gas law.

  • @fassaaug03
    @fassaaug03 Жыл бұрын

    Why does "in general" the gas velocity should be under 40 m/s? Laminar/turbulent flow? It is very far from the speed of sound that might cause any sort of undesirable effects

  • @bipl8989

    @bipl8989

    10 ай бұрын

    Noise and pipe erosion. Pressure drop is also usually too much. Actually for a more optimum economy for long distances, 20 to 30m/s is even better.

  • @jig577
    @jig5772 жыл бұрын

    please what is the name of the actual flow rate equation

  • @joergdyckerhoff471

    @joergdyckerhoff471

    Жыл бұрын

    Combined gas law

  • @Imsama123
    @Imsama1232 жыл бұрын

    may i know which reference these formulas came from?

  • @Imsama123

    @Imsama123

    2 жыл бұрын

    what is 3600 and 0.1 in the formula?

  • @adityaram7493

    @adityaram7493

    2 жыл бұрын

    @@Imsama123 hour unit was converted into seconds = 1 hour = 3600 seconds

  • @kbskbskbskbskbskbs

    @kbskbskbskbskbskbs

    2 жыл бұрын

    @@Imsama123 0.1 is related to the pressure. The original formula for normal volume flow rate and actual volume flow rate is (normal means at 273.15 kelvin and approx 100 000 pascal): Q = Q0 * (Z * T * p0) / ( Z0 * T0 * p) Z and Z: are compressibility and normal compressibility, not considered in this video The 0.1 in the formula (in the video) is due to p being in MPa and to p0 not being explicitly included in the formula.

  • @ShrinathSasane-nd6dq
    @ShrinathSasane-nd6dq10 ай бұрын

    For 3/4" line size Velocity = 23.09m/s

  • @Hello-qv4xm
    @Hello-qv4xm2 жыл бұрын

    How to calculate inner dia

  • @SimpleScience

    @SimpleScience

    2 жыл бұрын

    You can Google it.. Or use pipe data app from playstore

  • @yuvarajprasanna5775
    @yuvarajprasanna57753 жыл бұрын

    273.15 ? why the value came

  • @adityaram7493

    @adityaram7493

    2 жыл бұрын

    temperature is in kelvin unit

  • @vijaychauvhan6143
    @vijaychauvhan61432 ай бұрын

    23.13 m/s

  • @vijaylondhe05
    @vijaylondhe057 ай бұрын

    Gas velocity =23.13 m/s