COMMENT & SUBSCRIBE FIND US ON INSTAGRAM / chanyatafarm Fighting off the winter chill by installing a pellet stove in my workshop.
Жүктеу.....
Пікірлер: 62
@kevinhanson33093 жыл бұрын
If you know you are going to be drilling through thin metal with a hole saw, try this first. Get a scrap piece of wood larger than your hole. Maybe 3/4" thick. Plywood or solid, does not matter. Drill a hole. Remove the slug from the hole saw. Stick a pencil through the center hole in the slug and metal and use some drywall screws and attach to the siding or metal. Remove pencil. Drill your hole. The drill bit is really not necessary now and the slug is the exact inside diameter of the saw so no walking.
@ChanyataFarm
3 жыл бұрын
Nice tip
@a914freak3 жыл бұрын
Code for venting anything is typically 3 feet off the ground. If you get drifting snow its going to block that vent that close to the ground.
@ChanyataFarm
3 жыл бұрын
We so seldom get snows like that where I live it won’t be much of an issue, but you’re right
@MrAbsolutkaos Жыл бұрын
You could just have drilled from the out side in
@duanecoursey74016 ай бұрын
It is bad advice to run a pellet stove straight out because if the electricity goes out and the pellet stove goes out, smoke will enter through the stove. If you have at least a three or 4 foot rise on the outside it eliminates that so a rise is necessary.
@7akulwicki2 жыл бұрын
Any horizontal run should have 1/4 inch upward slope per foot, not angled downward.
@jaybarnhart89202 жыл бұрын
You Need a horizontal rise outside about 3ft bud at least lol
@hippiewithacowboyhat2 жыл бұрын
Too damn much math. Go outside, between ribs, and drill the damn hole to the inside...
@ChanyataFarm
2 жыл бұрын
Measure twice cut once lol!
@IAMElectric369
2 жыл бұрын
Lol, that’s what I said before scrolling down and seeing your comment.
@pundamilia1191
2 жыл бұрын
@@IAMElectric369 Me too
@peterkasala20882 жыл бұрын
Should never have a drop horizontally through the wall. It should be level if not rise slightly. Should also have a minimum vertical rise of at least 3 ft preferably 5 ft to assist in venting before terminating vent. No cleanout??
@hubster4477
8 ай бұрын
Nope, horizontal vent is all you need.
@avap2677 Жыл бұрын
Nice to see ,but please drill more horizontal then you did . And a lot higher output .
@RCPLANET19622 жыл бұрын
Nice and level?
@tadday6157 Жыл бұрын
What kind of pellet stove did you use? Love the simple venting you did, perfect for a shop
@ChanyataFarm
Жыл бұрын
It’s a Pell Pro brand. Menards carries them
@TheShutterfly2 жыл бұрын
Hello, if your getting a smoke smell in your house after first day of firing the stove up, what would your steps be to see where its coming from?
@ChanyataFarm
2 жыл бұрын
The first thing I would try is right at initial start up of the stove, while the fire is still burning smokey, turn off the lights and shine a flashlight on all of your pipe joints and see if you see any smoke infiltration at the joints
@ChanyataFarm
2 жыл бұрын
Do the same with the gasket around the door to make sure it isn’t leaking there either
@loganbradley8276
Жыл бұрын
What are you gonna do if you need to take apart the ventilation pipe? You used silicone wouldn't that make it hard to pull apart
@danec75688 ай бұрын
Just got this same stove and wanna do the straight out the wall set up like you did have you had any issues with the way you set it up? Thanks!
@ChanyataFarm
8 ай бұрын
We have had no issues, it works like a champ. *Disclaimer- this is NOT the manufacturer’s recommended installation
@RICHIE_RICH893 жыл бұрын
Not far enough from the garage outside
@tomconnors63102 жыл бұрын
Love you shop. I find the outside vent is a bit low. Here in Ontario Canada the higher the vent the better to prevent snow blockage. Liked the video.
@brianfitzgerald3835 Жыл бұрын
Where is your clean out T?
@wawacameroon
7 ай бұрын
I also didn't see his fresh air intake. Hmmm...
@WibbyKDX
6 ай бұрын
Isn’t going to need a clean out with a run like that And as stated in video it’s not an air tight space so no need for fresh air intake
@mikewinn14846 ай бұрын
How much smoke do it put out?
@ChanyataFarm
6 ай бұрын
Very little once it is lit
@MargisonGODBEY9 ай бұрын
It will work but it needs a pipe going up 3 ft
@hubster4477
8 ай бұрын
Nope, horizontal is all you need.
@MargisonGODBEY
8 ай бұрын
@@hubster4477 not if it snows
@hubster4477
8 ай бұрын
@@MargisonGODBEY it doesnt where they are at.
@harlandmct
5 ай бұрын
@@hubster4477 You need a minimum 3 foot run up in case the power goes out. Without that run your house will fill with smoke if the power fails while the stove is running. Would not be fun. A horizontal termination like that will only work if the power doesn't fail.
@hubster4477
5 ай бұрын
@@harlandmct right, ive had the power go out a few times, there is smoke but its not that bad, not often and not bad enough to change things around. Someone burning popcorn is worse!
@rickdixon993311 ай бұрын
Why didn't you just drill from the outside in...?😊
@ChanyataFarm
11 ай бұрын
The elevations aren’t the same.
@a914freak3 жыл бұрын
Does the vent make the outsde wall black from sooting?
@ChanyataFarm
3 жыл бұрын
A little bit so far, but nothing I can’t live with
@MAD14502 жыл бұрын
Whatever this guy did do the opposite !!! People came here for an education and they got scammed. Kinda like college but all they lost was time Hopefully they don't burn their house down !!
@davewhipple4815
Жыл бұрын
Dam look like a nice job, could have done a few things differently....
@Bones12203 жыл бұрын
I could see the math on your EYES
@ChanyataFarm
3 жыл бұрын
👨🏻🏫👨🏻🏫👨🏻🏫
@back2backjack13 жыл бұрын
U really went cheap on the chimney! What about a clean-out??? What about a little rise to get the exhaust off the ground?? Oh well! to each his own!! I did give U a like cause of my BS.
@ChanyataFarm
3 жыл бұрын
Thanks for watching Robert! If it was in my house I would have done some of those things, but on the barn, I think this will be fine.
@a914freak
3 жыл бұрын
Yea 3' off tbe ground is code. Definitely a potential to be blocked by drifting snow.
@alcantrell5340
Жыл бұрын
What about the draft ? Stove won’t burn efficiently without a draft from the stove pipe, it needs at least 4/5’ vertical run. And no clean out? It will quit working from fly ash build up.
@WibbyKDX
6 ай бұрын
@@alcantrell5340how exactly is the ash going to build up? It’s going straight outside
@WibbyKDX
6 ай бұрын
Pellet stoves have a draft fan
@kaseycasece13403 жыл бұрын
young man , u did complete wrong outside uor shop to close the ground !
@georgestyer21533 жыл бұрын
I really like the info..but...you are not the star...I really hate when I look for info then a face appears...Personal preference but show me what you are doing !!
Пікірлер: 62
If you know you are going to be drilling through thin metal with a hole saw, try this first. Get a scrap piece of wood larger than your hole. Maybe 3/4" thick. Plywood or solid, does not matter. Drill a hole. Remove the slug from the hole saw. Stick a pencil through the center hole in the slug and metal and use some drywall screws and attach to the siding or metal. Remove pencil. Drill your hole. The drill bit is really not necessary now and the slug is the exact inside diameter of the saw so no walking.
@ChanyataFarm
3 жыл бұрын
Nice tip
Code for venting anything is typically 3 feet off the ground. If you get drifting snow its going to block that vent that close to the ground.
@ChanyataFarm
3 жыл бұрын
We so seldom get snows like that where I live it won’t be much of an issue, but you’re right
You could just have drilled from the out side in
It is bad advice to run a pellet stove straight out because if the electricity goes out and the pellet stove goes out, smoke will enter through the stove. If you have at least a three or 4 foot rise on the outside it eliminates that so a rise is necessary.
Any horizontal run should have 1/4 inch upward slope per foot, not angled downward.
You Need a horizontal rise outside about 3ft bud at least lol
Too damn much math. Go outside, between ribs, and drill the damn hole to the inside...
@ChanyataFarm
2 жыл бұрын
Measure twice cut once lol!
@IAMElectric369
2 жыл бұрын
Lol, that’s what I said before scrolling down and seeing your comment.
@pundamilia1191
2 жыл бұрын
@@IAMElectric369 Me too
Should never have a drop horizontally through the wall. It should be level if not rise slightly. Should also have a minimum vertical rise of at least 3 ft preferably 5 ft to assist in venting before terminating vent. No cleanout??
@hubster4477
8 ай бұрын
Nope, horizontal vent is all you need.
Nice to see ,but please drill more horizontal then you did . And a lot higher output .
Nice and level?
What kind of pellet stove did you use? Love the simple venting you did, perfect for a shop
@ChanyataFarm
Жыл бұрын
It’s a Pell Pro brand. Menards carries them
Hello, if your getting a smoke smell in your house after first day of firing the stove up, what would your steps be to see where its coming from?
@ChanyataFarm
2 жыл бұрын
The first thing I would try is right at initial start up of the stove, while the fire is still burning smokey, turn off the lights and shine a flashlight on all of your pipe joints and see if you see any smoke infiltration at the joints
@ChanyataFarm
2 жыл бұрын
Do the same with the gasket around the door to make sure it isn’t leaking there either
@loganbradley8276
Жыл бұрын
What are you gonna do if you need to take apart the ventilation pipe? You used silicone wouldn't that make it hard to pull apart
Just got this same stove and wanna do the straight out the wall set up like you did have you had any issues with the way you set it up? Thanks!
@ChanyataFarm
8 ай бұрын
We have had no issues, it works like a champ. *Disclaimer- this is NOT the manufacturer’s recommended installation
Not far enough from the garage outside
Love you shop. I find the outside vent is a bit low. Here in Ontario Canada the higher the vent the better to prevent snow blockage. Liked the video.
Where is your clean out T?
@wawacameroon
7 ай бұрын
I also didn't see his fresh air intake. Hmmm...
@WibbyKDX
6 ай бұрын
Isn’t going to need a clean out with a run like that And as stated in video it’s not an air tight space so no need for fresh air intake
How much smoke do it put out?
@ChanyataFarm
6 ай бұрын
Very little once it is lit
It will work but it needs a pipe going up 3 ft
@hubster4477
8 ай бұрын
Nope, horizontal is all you need.
@MargisonGODBEY
8 ай бұрын
@@hubster4477 not if it snows
@hubster4477
8 ай бұрын
@@MargisonGODBEY it doesnt where they are at.
@harlandmct
5 ай бұрын
@@hubster4477 You need a minimum 3 foot run up in case the power goes out. Without that run your house will fill with smoke if the power fails while the stove is running. Would not be fun. A horizontal termination like that will only work if the power doesn't fail.
@hubster4477
5 ай бұрын
@@harlandmct right, ive had the power go out a few times, there is smoke but its not that bad, not often and not bad enough to change things around. Someone burning popcorn is worse!
Why didn't you just drill from the outside in...?😊
@ChanyataFarm
11 ай бұрын
The elevations aren’t the same.
Does the vent make the outsde wall black from sooting?
@ChanyataFarm
3 жыл бұрын
A little bit so far, but nothing I can’t live with
Whatever this guy did do the opposite !!! People came here for an education and they got scammed. Kinda like college but all they lost was time Hopefully they don't burn their house down !!
@davewhipple4815
Жыл бұрын
Dam look like a nice job, could have done a few things differently....
I could see the math on your EYES
@ChanyataFarm
3 жыл бұрын
👨🏻🏫👨🏻🏫👨🏻🏫
U really went cheap on the chimney! What about a clean-out??? What about a little rise to get the exhaust off the ground?? Oh well! to each his own!! I did give U a like cause of my BS.
@ChanyataFarm
3 жыл бұрын
Thanks for watching Robert! If it was in my house I would have done some of those things, but on the barn, I think this will be fine.
@a914freak
3 жыл бұрын
Yea 3' off tbe ground is code. Definitely a potential to be blocked by drifting snow.
@alcantrell5340
Жыл бұрын
What about the draft ? Stove won’t burn efficiently without a draft from the stove pipe, it needs at least 4/5’ vertical run. And no clean out? It will quit working from fly ash build up.
@WibbyKDX
6 ай бұрын
@@alcantrell5340how exactly is the ash going to build up? It’s going straight outside
@WibbyKDX
6 ай бұрын
Pellet stoves have a draft fan
young man , u did complete wrong outside uor shop to close the ground !
I really like the info..but...you are not the star...I really hate when I look for info then a face appears...Personal preference but show me what you are doing !!
@Adimondinthesky
3 жыл бұрын
He's the star in my book!