PB980 Video

How to properly set up, SST, and initiate ventilation with the Puritan Bennit 980 ventilator.

Пікірлер: 16

  • @mobenah
    @mobenah4 жыл бұрын

    very good presentation, I like the close ups, I was hoping though during SST that you zoomed down so we can see what is being removed or added, but otherwise very informative.

  • @ma0091
    @ma00916 жыл бұрын

    Thank you very much. Really helpful.

  • @antoninonastasi3719
    @antoninonastasi3719 Жыл бұрын

    Aerogens go on the dry side per the aerogen quick reference guide FYI

  • @latentimage74

    @latentimage74

    2 ай бұрын

    yep, I talked to Jim fink in an elevator about the same thing once

  • @Malficion
    @Malficion6 жыл бұрын

    Ah... Good times, first semester, we did a tour of the lab. My smart self saw a flippy switch and turned on the 980. The lab professor was pissed. Apparently they were 70k+ a piece and if the cap was on it the machine would get damaged.

  • @williamhuang4140
    @williamhuang41404 жыл бұрын

    Thank you so much

  • @mdtoufikul6430
    @mdtoufikul64303 жыл бұрын

    very good presentation,

  • @hunteroftruth4986
    @hunteroftruth49863 жыл бұрын

    To fix that leak failure issue tear the small cap covering your water feed line from the chamber cover and press it on firmly.

  • @idaliab1
    @idaliab15 жыл бұрын

    There are some HME'S that are design for aerogen, which it has a tab that goes up and down so you can give the neb tx's

  • @tamraparrish3526
    @tamraparrish35266 жыл бұрын

    What about the amount of dead space for the aerogen? Or do you not need to worry about that with the aerogen?

  • @tamraparrish3526
    @tamraparrish35266 жыл бұрын

    At the facilities I have worked at we use the aerogen with an HME, but we put it in front of the HME closest to the patient.

  • @rhenmitchell5629

    @rhenmitchell5629

    6 жыл бұрын

    Tamra Parrish it has been my experience that ventilated patients receiving aerogen therapy also require frequent suctioning and we require etco2 monitoring for all vent patients. Usually this makes an HME impracticle.

  • @rhenmitchell5629

    @rhenmitchell5629

    6 жыл бұрын

    Dead space from an inline aerogen is negligent for nearly all adult patients. In the case of neonates, most modern ventilator utilize flow sensors at the end of the inspiratory circuit, which will cause the vent to automatically compensate for deadspace based on insp/exp measurments. If your neonatal vent doesnt have a flow sensor, then you may have to adjust your settings.

  • @montadharaltaii7604
    @montadharaltaii76043 жыл бұрын

    What's the damages of this ventilator please

  • @cecilialee186
    @cecilialee1863 жыл бұрын

    I don't know thatvI agree with where he put the aerogen. The company recommends the dry side.

  • @bfrancioso
    @bfrancioso5 жыл бұрын

    The 840 is better