MetraHit IM Xtra tests on my winding simulator

Ғылым және технология

#MetraHit #IMXtra
Testing the functionality and performance of the MetraHit IM Xtra BT on my winding simulator. 2 and 4 wire winding resistance measurements followed by polarisation index measurement.
Results are captured with the Metralog software on a tablet and then analysed using Microsoft Excel.
Gossen Metrawatt IM Xtra
www.gossenmetrawatt.de/en/pro...
Available from GMC UK
www.gmciuk.com/metrahit-im-xt...
0:00 Introduction
0:37 Bluetooth Connection
01:02 Metralog Software
1:37 2-Wire Winding Resistance Measurement
3:45 4-Wire Winding Resistance Measurement
6:50 Polarisation Index Measurement
9:11 Insulation Resistance Accuracy
9:38 Insulation Accuracy Comparison
10:08 Insulation Test Output Performance
12:15 Meter PI Test Screen
13:24 Metralog PI Test Screen
16:11 Winding Resistance Analysis
18:23 Polarisation Index Analysis
21:17 Summary

Пікірлер: 6

  • @TheElectriciansToolChannel
    @TheElectriciansToolChannel4 ай бұрын

    That's a really nice and highly advance meter. Very well explained and detailed video TP as usual👌👌👌👌👌👌

  • @three-phase562

    @three-phase562

    4 ай бұрын

    Thanks for watching TETC. 👍👍

  • @burnedupsparkytipsandrevie9597
    @burnedupsparkytipsandrevie95974 ай бұрын

    Man if that could preform a surge test that would be great for testing cooling tower motors instead if lugging up a baker away 5 flights of stairs. Also is the 4 wire resistance measurement a EU testing requirement? Still surprised fluke hasn't made a portable IR and DLRO stand alone unit.

  • @three-phase562

    @three-phase562

    4 ай бұрын

    Whilst it seems to perform some sort of a surge test, it isn't returning the typical waveform, but provides a numerical time value for comparison across the phases. I haven't found 4-wire resistance mentioned in the IEC 60034 series for rotating machines. It is within the 60076 series for transformer winding measurements and 62271 for breaker testing. It was in the old IEEE 118 standard, but that was withdrawn in 2005, and I have not seen a replacement. I have only seen combined IR and DLRO units from Gossen and Megger, but the other manufacturers may produce some, although you are getting into more niche requirements. What size are the cooling tower motors? At the moment I have tested this unit on motors up to 1 MW and got readings okay. Appreciate you watching and commenting 👍👍

  • @oneq1588
    @oneq15883 ай бұрын

    what is the Part Number of this multimeter?

  • @three-phase562

    @three-phase562

    3 ай бұрын

    The IM Xtra BT that I have is part number M273S