Mellerware kettle element damaged

Fault finding on the Mellerware kettle. Unfortunately a fix isn't worth while.

Пікірлер: 47

  • @antonios4926
    @antonios49265 жыл бұрын

    Thanks for the video. You taught me something. From Cyprus

  • @hosraiyan
    @hosraiyan5 жыл бұрын

    Good explaination sir,for me you help a lot of.

  • @sharpasfhuuk7355
    @sharpasfhuuk73556 жыл бұрын

    Weird how cheap kettles last me years but expensive ones lucky to make it to 12 months

  • @glasser2819

    @glasser2819

    4 жыл бұрын

    just like German cars vs. Toyota !

  • @kristaps2010
    @kristaps20102 жыл бұрын

    Thank you 8:15 that’s what I wanted to find out. My element shows 2.86 ohmes. I already cut of that cement thing (resistor) as I couldn’t get continuity beep there although led’s were working. Just learning…

  • @babythomas2902
    @babythomas29022 жыл бұрын

    Sir, The heating element is changeable ? Can we change the coil from the bottom of the Kettle.? A Kettle element shows 21 ohms in diod testing mode. is the element is ok.or not ? Please replay

  • @taurene
    @taurene5 жыл бұрын

    as long as the kettle heating element is working, the only way you can make it work again is by replacing the thermostat switch assembly (available in ebay) and the base connection due to wear & tear, i made an adjustment and use the center pin and the ground green-yellow connection pin and the same adjustment made the grounding connection to heating element

  • @davidejukorlem6298

    @davidejukorlem6298

    2 жыл бұрын

    A

  • @MoMaMeg
    @MoMaMeg6 жыл бұрын

    what if dry element touched the water, is it's color will changed to pink? this is the case that i faced

  • @piecetoyou8285
    @piecetoyou82855 жыл бұрын

    Hi,thank you for explaing the ohms law, I worked out 230v at 3000w 13.0 amps and 240v at 250w at 10.41 amps. My kettle is 220-240v 50-60Hz 2500-3000w, So I kind of done two working outs as shown above.My kettle reading in ohms is showing 19.5 would my eliment be broken, if not would the LED light stop the connection if that has gone bad

  • @JanDuToit

    @JanDuToit

    5 жыл бұрын

    Remember the Voltage is whatever your supplier gives you and stays relatively the same. The frequency (Hz) will never change for your country. Kettles are not precision devices. They will work in a range of conditions and at the range of efficiencies. 19Ohms should still be alright for your kettle. And no, the LED should not stop your kettle from working as it should be connected in parallel. Check the connection between the base and the kettle itself. Check your cord. Check your oulet plug, take the kettle to another room and she if it works on one of those plugs. It may be possible that your kettle is fitted with a thermal cutout device that could be reset or should be replaced. They are normally installed in the neutral line for whatever reason.

  • @piecetoyou8285

    @piecetoyou8285

    5 жыл бұрын

    I noticed live wire some how was pinched in the base part that has the lead connected, this is showing bare wire,the connection as melted a bit and at the base of the kettle section, the two copper connectors you show one has slight burn to it,I tested every thing as you shown all seams to work, so I will rewire the mains lead and clean the black on the copper, and quickly check the cut out be for reassembling, .Thanks for info

  • @piecetoyou8285

    @piecetoyou8285

    5 жыл бұрын

    I had fix it,it was a smeg kettle ,worth fixing for what it cost,only possible due to your video,knowing the ohms were good from the element,it gave me encouragement to carry on with the wiring,cheers

  • @nnm35

    @nnm35

    4 жыл бұрын

    @@JanDuToit : Good tips, maybe you could copy this and the Ohms Law caluculation formula into your description at the top? Thanks for posting, this is helping me understand!

  • @213163
    @2131632 жыл бұрын

    Thank you - Nice South African video and explanation.

  • @mohammedhakumi5959
    @mohammedhakumi59595 жыл бұрын

    Thanks a lot Jan Du Toit for this video , but can u please help me to fix a thermal switch which refuse to be latched " ON" when I switch it "ON" ..... the kettle boiling water fine ,but only I have to keep pressing the switch On by my finger, so how can I fix it please ?.....Also , on the same kettle type (good condition one) I did notice that the thermal switch would not be latched "ON" unless the kettle was connected to the power , so why is that please ?...... is the elect. power effects on latching mechanism any way ?

  • @JanDuToit

    @JanDuToit

    5 жыл бұрын

    Firstly, I am not a pro repair guy, I just record what I do at home with my own stuff. And I am unfortunately not going to open my perfectly working kettle to check what I can see, so what I'm about to post is just speculation So I just tested on my kettle and you are right, it cannot latch if not connected to the base. So the kettle needs power to latch the switch to on. This tells me that it uses an electromagnet to latch the switch, just like a relay. So my assumption will be that there is a small wire running to a coil inside the switch that is broken off. Or it can be the coil of the electromagnetic switch that is broken. If we are right and it is an electromagnetic switch, this latching needs to occur between the electromagnet and something metal. So it could also be that there is a small metal plate that maybe broke off or moved in such a way that it cannot latch anymore. Either way, you are going to have to open the switch to see what is going on in there.

  • @mohammedhakumi5959

    @mohammedhakumi5959

    5 жыл бұрын

    Thank u Jan Du Toit for reply , I think through this presentation in this video u are good enough to overcome any possible trouble in these kind of appliances. I have already dismantled the kettle and I found it exactly the same with the one u have in this video . I have no idea about the principal of working of the thermal switch on it and I am sure there is no like a relay involved in the electric circuit of the switch and this makes me seeking for some advice to understand theory of operation then it may help me to fix the problem.

  • @yogenrai5651
    @yogenrai56514 жыл бұрын

    Sir I have a kettle I have done everything you have mentioned above ..I even checked the element and its resistance value is ok but still the kettle is not being on ..When I take out the element connections the light gets on according to the switch but when i connect it with the element it dosent glow

  • @stefanbachrodt7072
    @stefanbachrodt70726 жыл бұрын

    From now on I only buy kettles with the option for extended warranty. If they don't have confidence in the quality of their products, nor do I.

  • @garthwilliamjones2777
    @garthwilliamjones27774 жыл бұрын

    Dankie boet, you saved me the hassle of wasting my time.

  • @tonyulriksen6532
    @tonyulriksen65324 жыл бұрын

    Thank you for this video, I am facing a kettle with similar connection - which is intermittent. I think I may know how to fix it now.

  • @bosco50050
    @bosco500506 жыл бұрын

    thanks for the explanation

  • @JoseSilva-oi2wi
    @JoseSilva-oi2wi4 жыл бұрын

    I dont understand why my kettle isnt working. The multimeter shows everything ok

  • @hermanmyburgh8309
    @hermanmyburgh83094 жыл бұрын

    Dankie Jan

  • @GamesRoom109
    @GamesRoom1094 жыл бұрын

    I accidentally turned on my kettle and it shuts off from burning With no water

  • @AP-bo1if
    @AP-bo1if4 жыл бұрын

    all kettles whether cheap or expensive seem to share the same/similar parts, all made in China. my conclusion is therefore; buy the cheapest kettle on the market.

  • @avilevy3606
    @avilevy36062 жыл бұрын

    Thank you

  • @moyahaboc5868
    @moyahaboc58684 жыл бұрын

    Thanks, this was helpful

  • @shahiedjohnson1964
    @shahiedjohnson1964 Жыл бұрын

    On what setting must my multy meter tester be to test my element of my earn

  • @tempestv8

    @tempestv8

    Жыл бұрын

    Set the selector dial to Ω (ohm)

  • @asangamendis6105
    @asangamendis61053 жыл бұрын

    We know how to replace element can u do a video about on off switch not working it is slide to one side 😄

  • @hatdetulsiram8116
    @hatdetulsiram81165 жыл бұрын

    How to change heating element

  • @philp537

    @philp537

    4 жыл бұрын

    I've just realized my element is cracked - kettle went out with a blue flash. I've removed my kettle element, but I don't know where to get a new one. Different kettle than the kettle in the video.

  • @MSTECHCHANNEL
    @MSTECHCHANNEL6 жыл бұрын

    good

  • @herbertranuda3278
    @herbertranuda32786 жыл бұрын

    What if there is light but not heat?

  • @JanDuToit

    @JanDuToit

    6 жыл бұрын

    Herbert Ranuda The element is probably broken.

  • @herbertranuda3278

    @herbertranuda3278

    6 жыл бұрын

    What can I do to repair it?

  • @JanDuToit

    @JanDuToit

    6 жыл бұрын

    If you have this kettle, nothing. The element is unfortunately not replaceable.

  • @herbertranuda3278

    @herbertranuda3278

    6 жыл бұрын

    Did you mean I can't get it fixed?

  • @JanDuToit

    @JanDuToit

    6 жыл бұрын

    Yes, that is what I meant.

  • @KEBOITUMELOTHEONEONLY-qr3gt
    @KEBOITUMELOTHEONEONLY-qr3gt Жыл бұрын

    It's freezing

  • @EnkaePrestigeMotors
    @EnkaePrestigeMotors4 жыл бұрын

    KETTLES ARE £8 BRAND NEW

  • @balkrishna7715
    @balkrishna77153 жыл бұрын

    Meri ketali ki Koyal kharab hai

  • @Hoekstes
    @Hoekstes Жыл бұрын

    Selle ketel. Ook moer toe. 😂

  • @kjtvninja6053
    @kjtvninja60533 жыл бұрын

    can not udetstand english

Келесі