Mastering HVAC: The Ultimate Guide to Twinning Gas Furnaces

Join this channel to get access to perks:
/ @taddydigest
Wanna Learn more about hvac? Check out my hvac tips for technicians playist.
• HVAC Tips for Technicians

Пікірлер: 66

  • @wrewgawrew5261
    @wrewgawrew5261 Жыл бұрын

    Watching your videos makes me feel like I was robbed when apprenticing. I'm binge watching!

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    thank you for watching 👀 😀

  • @noone3690
    @noone369020 күн бұрын

    Hello, first off I enjoy your content. No one is out here trying to teach new techs correct practices. We wanna see a twinned system ac and coil/components and installing tips.

  • @dontarguewithfools
    @dontarguewithfools Жыл бұрын

    Man you are going places. Good stuff man. Stay humble Thank you

  • @ronnyallspeed2108
    @ronnyallspeed210810 ай бұрын

    Installing one tomorrow, got the units in, and this video and comments gave me very good insight into what is going on. I'm using a twining board, but if that doesn't work, I feel confident because I can always fall back on the 24v relay option.

  • @TaddyDigest

    @TaddyDigest

    10 ай бұрын

    Very cool, bro

  • @user-sm3pt1lt2y
    @user-sm3pt1lt2y5 ай бұрын

    Don’t necessarily need a relay just a jumper wire but great video!

  • @royalserviceairconditionin2703
    @royalserviceairconditionin2703 Жыл бұрын

    Marry Christmas brother. We love your work and happy to make your educational videos part of our daily activity. we hope to see your work next year. Happy New Year.

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    Thank you my friend really appreciate you watching my videos Definitely more content to come I hope you had a blessed year and I hope next year is even better

  • @CBrown07696
    @CBrown07696 Жыл бұрын

    Love the set up. The biggest problem I run into is trying to figure out what the guy before me did. I love a good Frankenstein but an out in the open “industry standard” fix that doesn’t make my tiny brain hurt is awesome.

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    This was exactly what you are talking about Both of these systems were messed up and not wired properly there were actually 2 relays instead of one and I had to remove 1 of the relays so I know what you're talking about

  • @CBrown07696

    @CBrown07696

    Жыл бұрын

    @@TaddyDigest That is my life. I’ve been doing a lot of work for an apartment complex that was built in the 40s. My frustration had got to the point that I finally talked to the head maintenance guy and told him that he was paying me to fix stuff that his other two crews are screwing up and he was paying for the same word twice. He told me it was in the budget. The other two crews are cheap and he knows they get about 80% of it right so they budget in me batting clean up. I stopped shaving my bill thinking he was loosing money on rework.

  • @sergioramirez9025
    @sergioramirez9025 Жыл бұрын

    Bro I am super stoked how you explain this wonderful tremendous knowledge that is very helpful and entertaining 👏 🙌 👌

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    You're welcome absolutely this video was for you Thank you for watching sergio

  • @ryanguzman3927
    @ryanguzman3927 Жыл бұрын

    I just did a twinning system today with S8X1 furnaces. Was curious if anyone has another way of doing it. I followed the wiring diagram in the booklet and it work great. Glad to see a video of it as well.

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    Awesome Very cool that you are willing to Look at the manual awesome

  • @Robnord1
    @Robnord1 Жыл бұрын

    All kinds of good info on your channel that those doing field repairs and videos just assume we already know. 👍 Subscribed.

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    Awesome, thank you!

  • @javlonkhojiev8531
    @javlonkhojiev8531 Жыл бұрын

    You did everything very nice 👍 In my opinion I would put the cheapest thermostat in the return air duct and connect both fan motors in one board! Cheep, fast and will work like second stage!

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    very good idea I like that 👍

  • @OcRefrig

    @OcRefrig

    Жыл бұрын

    On board Relays aren’t designed for the load of two motors. Relays will burn up.

  • @javlonkhojiev8531

    @javlonkhojiev8531

    Жыл бұрын

    @@OcRefrig No way! On board 20amps relay! And you can also take the two wire from relay signal and put one own relay!

  • @pb4life435
    @pb4life4359 ай бұрын

    How about when you also have 2 separate A/C condensing units? I totally like how you did it with a Peanut relay for heat.

  • @KyleNicks

    @KyleNicks

    3 ай бұрын

    I am curious about this as well

  • @donaldpainter956
    @donaldpainter956 Жыл бұрын

    So you are taking common and white and enigizing red and white on the other furnace ok that's a different way than I learned but nothing wrong with it thanks that's why I watch videos always learning a different way to do things keep em coming

  • @jakeholcombe4002
    @jakeholcombe40028 ай бұрын

    Tad do the transformers have to be set up a certain way for something like this

  • @hugomembreno4653
    @hugomembreno4653 Жыл бұрын

    Thank you sir very good information! Any possible way you can make a video on a twin system with a twinning board ,to see how does it work and maybe some troubleshooting on it.. God bless you sir .

  • @Tradesmen

    @Tradesmen

    Жыл бұрын

    That would be cool. Haven't seen anyone do a video on Twinning boards yet. I like to think about Twinning boards like Zoneboards, only you need an extra board for every system you need to sync phase. I've seen up to 6 furnaces on 1 thermostat. Crazy looking if you've never messed with it. There are some massive churches with this kind of set up. Remember K.I.S.S. in Hvacr. Its easy to over think it when fixing someone else's over thinking.

  • @mustafachacha442
    @mustafachacha442 Жыл бұрын

    Good job. Keep up the good work

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    thanks 👍

  • @jakeholcombe4002
    @jakeholcombe40028 ай бұрын

    I have a problem blowing a board on twined set up that is having issues I didn’t install units originally

  • @ritchpoint
    @ritchpoint8 ай бұрын

    Please can you explain this twining very well Sir

  • @hugomembreno4653
    @hugomembreno4653 Жыл бұрын

    can you possibly make a video on how to troubleshoot an actual twining module board . Please

  • @CBrown07696
    @CBrown07696 Жыл бұрын

    I’m working apartments built in the 1940’s that have been turned from two bedrooms to 3 bedrooms by removing a wall. They have central heat on one side and a floor furnace on the other side. I was wondering if I could do this twinning so the call for heat signal would be better on the floor furnace? We are replacing the 750mv thermostats like crazy since the floor furnaces are on a separate thermostat anyway.

  • @sakogara3849
    @sakogara3849 Жыл бұрын

    I enjoyed your video very clear and easy illustration I’m trying to twin 80,0000. BTU 2 stage furnace. If possible please can you give me some Idea or any illustrations? Thank you.

  • @briancarlisi2224
    @briancarlisi22247 ай бұрын

    I’m confused. Why add a relay to unit #2 for heat mode v. directly running your red & white wires from unit #1 to unit #2’s board? Thanks in advance!

  • @Nothingman88
    @Nothingman88 Жыл бұрын

    You the man! Edit: Thank you!

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    You're welcome!

  • @conspiraciesexposed7760
    @conspiraciesexposed7760 Жыл бұрын

    Ty bro

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    your welcome

  • @sergiohernandez4163
    @sergiohernandez41639 ай бұрын

    Which relay is that ?

  • @keithmoore3908
    @keithmoore3908 Жыл бұрын

    Like your setup plus know how join the group to get lead works & installed job

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    Awesome

  • @donaldpainter956
    @donaldpainter956 Жыл бұрын

    So this same relay setup would it work for a Taylor wood furnace so you could use the indoor blower of your furnace

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    yes

  • @Racossaid
    @Racossaid Жыл бұрын

    Why the relay you just put red two red white two white and so on Just like a regular furnace

  • @OcRefrig

    @OcRefrig

    Жыл бұрын

    Can’t do it. Each furnace has its own transformer. 1) if u disconnect one of the furnaces transformers might work if transformer is big enough to handle load of 2 boards and relays.

  • @Racossaid

    @Racossaid

    Жыл бұрын

    Thank you very much. I do appreciate you clarifying that for me. It’s a big help. Thank you.

  • @LuisCruz-sz3zv
    @LuisCruz-sz3zv8 ай бұрын

    What about the evaporator coil? Do you have two coil paired together or one big coil?

  • @TaddyDigest

    @TaddyDigest

    8 ай бұрын

    On this set up it was one big coil

  • @thomasklohr5433
    @thomasklohr543324 күн бұрын

    What do I do if one unit goes down? Is it safe to run the other unit while waiting for a repair?

  • @TaddyDigest

    @TaddyDigest

    24 күн бұрын

    Usually, you have to wait until the other unit is back up. And running Because it's usually one circuit and one large indoor coil

  • @rickbarber6758
    @rickbarber675810 ай бұрын

    Can't the second burner be wired so it acts like a two stage furnace? Better comfort.

  • @TaddyDigest

    @TaddyDigest

    10 ай бұрын

    yes, but the building needs the full btu to heat the structures load

  • @witnesscarter9118
    @witnesscarter9118Ай бұрын

    Do you have a part number for this relay

  • @TaddyDigest

    @TaddyDigest

    Ай бұрын

    I do, but I'll have to do another video to show you

  • @heatslayerhvacco.7990
    @heatslayerhvacco.7990 Жыл бұрын

    How does the refrigerant circuit work in those twin applications is there two line sets for each furnace evaporator coil that goes into a distributor box before it goes to condenser? I’m not familiar with those setups I’m mostly residential.

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    Only one set of line sets going into that coil The bigger the tonnage The more lion sets

  • @heatslayerhvacco.7990

    @heatslayerhvacco.7990

    Жыл бұрын

    @@TaddyDigest does each furnace have its own condenser?

  • @sonicblaster123
    @sonicblaster123 Жыл бұрын

    Can you explain how does the 2nd unit/board get energized in the cooling circuit if the R is only connected to the heating relay?

  • @sonicblaster123

    @sonicblaster123

    Жыл бұрын

    Any chance for an explanation on how the cooling circuit would run if the R is only hooked up to a relay in the heating circuit?

  • @80kenuel

    @80kenuel

    8 ай бұрын

    The 24v from the transformer of the second unit are always present on the relay just waiting for the signal from first unit to let it through.

  • @bill944
    @bill944 Жыл бұрын

    Don't understand why the relay is necessary on the twinning when running an additional set of thermostat wire from one furnace circuit board to the other would accomplish the same. Also, on the York set up, why isn't there a wire going to Y1 in the second furnace that's not being controlled by the thermostat? Won't that prevent the blower from coming on the the second furnace on a call for cooling?

  • @Duck1cVE

    @Duck1cVE

    7 ай бұрын

    Wiring board to board would not work, they both still need to use their own 24v power to peform the control

  • @linnell6103
    @linnell6103 Жыл бұрын

    How do i pay for the subscription so i can watchthose videos?

  • @TaddyDigest

    @TaddyDigest

    Жыл бұрын

    Join this channel to get access to perks: kzread.info/dron/uMyjTVlkM4xZ5z_eSyoB1w.htmljoin Wanna Learn more about hvac? Check out my hvac tips for technicians playist. kzread.info/head/PLVjetZt5xgenmO76adHwb2ctyeBIFKUus