Learn how to Run RO Software, Dupont software training, Hydronautics IMS software projection

With the help of RO software, learn to design RO projections. In 20 minutes of video, I am sure you will able to make RO projections. There are various softwares like IMS, wave, lg software , with help of this projection can be prepared.
Also this video gives glimpses of RO in detail. It tells what is RO and how to calculate RO membranes.
RO membranes can be calculated to give clean water manually but there are RO softwares which helps to determine it.

Пікірлер: 20

  • @Khizar_Ansari
    @Khizar_Ansari5 ай бұрын

    Thanks alot for the detailed explanation

  • @dipalidevisarmah1476
    @dipalidevisarmah1476 Жыл бұрын

    Thanks alot. Learnt a lot😊

  • @MeenuJainLalitpur
    @MeenuJainLalitpur3 жыл бұрын

    Hi, your video is really very nice. I would suggest to add more information in description and add tag in video, probably subscribers and views will start increasing. Also add your email or any contact so that audience can contact you for further information about water. All the best 👍

  • @WATERCAMPUS99

    @WATERCAMPUS99

    3 жыл бұрын

    Thank you for the comment . Description and tag I am adding but not in detail. Contact information i never thought of. I also see you are also from water background , it’s nice to get connect.

  • @MeenuJainLalitpur

    @MeenuJainLalitpur

    3 жыл бұрын

    @@WATERCAMPUS99 I know the initial struggle as a KZreadr, but I would say keep sharing your knowledge... we all are learning from each other, Lots of people need the information and your knowledge, keep sharing it. Appreciation, Blessings and lots of unpredictable things will automatically come to you.....

  • @WATERCAMPUS99

    @WATERCAMPUS99

    3 жыл бұрын

    Thanks a lot, these words will surely motivate me to work more hard for sharing knowledge with others. Rightly said that by sharing knowledge we also learn a lot.

  • @khizramujahid
    @khizramujahid2 жыл бұрын

    can we still choose seawater flux range if we are using ultrafiltration before RO? Do you have any tutorial on RO-UF integration with an energy recovery device?

  • @WATERCAMPUS99

    @WATERCAMPUS99

    2 жыл бұрын

    Yes UF act as just saftey to RO. So choose sea water flux with UF also . Ok , as you require will make tutorial for energy recovery device.

  • @felipeguajardo1190
    @felipeguajardo11902 жыл бұрын

    Hi, I have a question. I'm designing a desalination process to produce potable water for a small community near the cost (1000 habitants), the idea it's to obtain the seawater by a well bench (subsurface-intake) because has better quality than raw seawater (open-intake). But am having issues with the pretreatment. I'm just considering just using UF as pretreatment then RO and the post-treatment to obtain the quality of potable water. But I'm having issues with the use of acids in the intake water (sulfuric acid) because it is known that at lower ph the formation of bicarbonates it's reduced but the seawater has an acceptable range of Ph and UF, RO has a good range in PH terms. So my question is it is necessary to adjust the ph??. I'm using the WAVE software to simulate the process but am stuck with this part

  • @WATERCAMPUS99

    @WATERCAMPUS99

    2 жыл бұрын

    First of all its really a good cause for proving clean water for drinking purpose. Inlet ph has to be maintained around 6-7. As pretreatment use filters also before UF. This will increase both life abd reduce chemical consumption.

  • @felipeguajardo1190

    @felipeguajardo1190

    2 жыл бұрын

    @@WATERCAMPUS99 Thank you, that's a piece of good advice. The last question, do you know if the software provides post-treatment chemicals ???. In case it doesn't provide it, do you know a software where can I simulate de posttreatment ??

  • @Khizar_Ansari
    @Khizar_Ansari4 ай бұрын

    I only have TDS value. How do I balance anions and cations?

  • @WATERCAMPUS99

    @WATERCAMPUS99

    4 ай бұрын

    In that case, we have leave other ions and have to consider only Na Cl. With two you can balance out

  • @rameshpm2107
    @rameshpm21073 жыл бұрын

    useful information's thanks. Could you please share software download link?

  • @WATERCAMPUS99

    @WATERCAMPUS99

    3 жыл бұрын

    I have shown it in video. Nevertheless, link to download is www.dupont.com/water/resources/design-software.html

  • @lee-andredevilla1903
    @lee-andredevilla19032 жыл бұрын

    Does this have input for bacteria analysis?

  • @WATERCAMPUS99

    @WATERCAMPUS99

    2 жыл бұрын

    No Bacteria should be nil before feeding it into RO

  • @lee-andredevilla1903

    @lee-andredevilla1903

    2 жыл бұрын

    @@WATERCAMPUS99 yes, but is there an input parameters for bacteria in the feed water tab?

  • @sssttt4255
    @sssttt42555 ай бұрын

    How to balance cation anion

  • @WATERCAMPUS99

    @WATERCAMPUS99

    4 ай бұрын

    You have to finally balance it by NaCl