इन्वर्टर AC और नॉन इन्वर्टर AC में क्या अंतर होता है ||

इन्वर्टर AC और नॉन इन्वर्टर AC में क्या अंतर होता है ||

Пікірлер: 79

  • @AryanrajaAryanraja-iu6jz
    @AryanrajaAryanraja-iu6jz3 ай бұрын

    Aapka video bahut hi achha lagta hai Thank you sir ji

  • @hasratali7488
    @hasratali74883 ай бұрын

    Thank. U Kareem Bhai

  • @dhanuelectrician8964
    @dhanuelectrician89642 ай бұрын

    Nice video sir 🙏ji ❤

  • @akramsk-cz1ew
    @akramsk-cz1ew2 ай бұрын

    Thanks best information

  • @huzefabidani7367
    @huzefabidani73673 ай бұрын

    Great information

  • @badamsingh60
    @badamsingh602 ай бұрын

    Bahut achchhi video hii sar aapki

  • @arsealam4035
    @arsealam40352 ай бұрын

    Kareem bhai padane ka satyle bahut achha hai 🎉🎉

  • @mdarman07770
    @mdarman077703 ай бұрын

    Very nice sir ❤❤❤❤

  • @qumra5593
    @qumra55933 ай бұрын

    DC phase U, V and W used in AC motors to represent because in india using brites standard

  • @AnshuKumar-hu7bu
    @AnshuKumar-hu7bu2 ай бұрын

    Good sir g

  • @DeepakKumar-sc9oi
    @DeepakKumar-sc9oi29 күн бұрын

    Kab batayenge bhaiya charo ke bare me bataiye please please please please

  • @anupsahani676
    @anupsahani6762 ай бұрын

    Chiller plant pr video btaiye sir

  • @user-rm3no5lk1y
    @user-rm3no5lk1y3 ай бұрын

    Sir split AC shifting ke time gas store kaise kare please bata do

  • @vakeelhashmi1519

    @vakeelhashmi1519

    3 ай бұрын

    Ac On kar Ke Compresser full Running pe Aa Jaye 5min ya 10 chalne ke Bad Discharge Line Band (Patli pipe) L-key Se Band Kar do Phir Agar Pipe Ki lamdai Ya Indoor Se Outdoor Door hy to 5 wait kr lo uske bad suction Line bhi Band Kar do Is Tarah Gas Restore ho jayegi

  • @amitsahani2157

    @amitsahani2157

    3 ай бұрын

    अधूरा ज्ञान मत दोंभाई खतरनाक हो सकता है​@@vakeelhashmi1519

  • @vishnulion4u
    @vishnulion4u2 ай бұрын

    Sir ji Daikin inverter 22 use old model me Kiya hey

  • @sandipyadav5848
    @sandipyadav58483 ай бұрын

    Sir aap regular class open rakhte hai

  • @realmountainscenery1523
    @realmountainscenery15232 ай бұрын

    Inverter compressor three phase ka hota hai jaise AC motor winding 3 phase ki hoti hai waise hota hai star delta connection

  • @ashnidevboss2861
    @ashnidevboss286116 күн бұрын

    Sir it will be better if u Write in Hindi

  • @thirunahariprabhakar6560
    @thirunahariprabhakar65602 ай бұрын

    ❤2good🎉

  • @user-rm3no5lk1y
    @user-rm3no5lk1y3 ай бұрын

    Sar vacuum pump mai single stage and double stage mein kya fark hai

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    3 ай бұрын

    Double stage jaldi vaccum kar dega

  • @entertainmentfanclub9402
    @entertainmentfanclub94023 ай бұрын

    Sir parts ki checking aur falt finding & questions answer pe बनाइए

  • @Sharmajishortvideo5946
    @Sharmajishortvideo59462 ай бұрын

    Sir dubule door fridge me inverter technology or non inverter technology me kya antar hai please batay sir

  • @Azamgahr786
    @Azamgahr7862 ай бұрын

    Sir ji inviter ac pcb ke upar video 📹 upload 📹 karo sir ji

  • @mponlineservices
    @mponlineservices3 ай бұрын

    Nice important Topic ⭐

  • @user-rm3no5lk1y
    @user-rm3no5lk1y3 ай бұрын

    Hi sir how are you

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    3 ай бұрын

    Fine

  • @huzefabidani7367
    @huzefabidani73672 ай бұрын

    Purane ac me non inverter ac ke outdoor me condensor ke output me sensor lga hota he

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    2 ай бұрын

    Hp switch hoti hai high pressor hone pe compressor ko band kar deti hai

  • @Pakistani-series_short
    @Pakistani-series_short2 ай бұрын

    Ghr khha pe hai

  • @onepoint3161
    @onepoint316123 күн бұрын

    Aapka kahana hai inverter AC mein r22 gas nahin dhalti but Mera kahana hai inverter AC mein r22 ka model Maine khud dekha hai Daikin company ka old model r22 mein vah system work kar raha hai

  • @sandipyadav5848
    @sandipyadav58483 ай бұрын

    Sir kab se class start huaa hai

  • @webtechnology1553
    @webtechnology15533 ай бұрын

    किसी किसी नान इन्वर्टर एसी स्प्लिट एसी में आउटडोर में भी पीसीबी होता जिसमे odu मोटर डीसी करेंट से चलता है। और उसमे एंबियेंट temp सेंसर भी लगा होता।hitechi के एक दो माडल में होता।

  • @user-rm3no5lk1y
    @user-rm3no5lk1y3 ай бұрын

    Sir AC service ke time PCB nikalna jaruri hai ya nahin

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    3 ай бұрын

    Nahi Achchhi tarah pcb ko dhak dijiye

  • @RashidAnsari-pe8hr

    @RashidAnsari-pe8hr

    2 ай бұрын

    Bhai AC Sarvice karte time Pcb nikalna important hai kyuki Usme Pani chal Jaye ga na to kharab ho Jaye gaa

  • @Mahesh.K.Ac.Technician
    @Mahesh.K.Ac.Technician2 ай бұрын

    Good afternoon sir Me online class karta hu or class Puri ho chuki hai hame satick fitick chahiye

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    2 ай бұрын

    3000 ka kharcha ayega

  • @AJJUBHAI-fo3ly
    @AJJUBHAI-fo3ly2 ай бұрын

    Sir aazamgarh me iti college hai

  • @Thukai-Operater
    @Thukai-Operater3 ай бұрын

    May ka batch kab se shuru hoga

  • @onepoint3161
    @onepoint316123 күн бұрын

    Uvw ko Apne wire ke anusar hi lagana chahie u ka w mein u v mein nahin Laga sakte Jo print compressor ke upar uvw ka hota hai vahi print PCB card ke andar bhi uvw ka likha hota hai kabhi check karna aap log

  • @tamnnagharu3218
    @tamnnagharu3218Ай бұрын

    Inverter AC se nuksan ho skta h kya

  • @Pakistani-series_short
    @Pakistani-series_short2 ай бұрын

    Sir aap khha se hai

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    2 ай бұрын

    Up azamgarh se

  • @user-rm3no5lk1y
    @user-rm3no5lk1y3 ай бұрын

    Service ke kitne der bad chalana chahiye ac

  • @mohdshamsher4525

    @mohdshamsher4525

    2 ай бұрын

    Kam se Kam 2 ghante

  • @salmanwriter3971
    @salmanwriter39712 ай бұрын

    Inveter ac 0 amp se start hoti h sir

  • @mponlineservices
    @mponlineservices3 ай бұрын

    Sir Accumileter ka karya kya he

  • @AkashYadav-jd5wz

    @AkashYadav-jd5wz

    3 ай бұрын

    Compressor me liquid gas jane se rokta h Nami , jane se rokta h Gas filtar karta h

  • @mohammadimran8374
    @mohammadimran83742 ай бұрын

    Assalamualaikum Sir Mera sawal hai Kya inverter ac ke out door PCB ke kharab hone par non inverter ac ka outdoor Laga sakte hai contactor Wala out door Please Sir answer me Bahut mehrabani hogi Please

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    2 ай бұрын

    Nahi laga sakte

  • @nijamuddinAnsari97
    @nijamuddinAnsari973 ай бұрын

    Assalamualaikum sir kaise Hain

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    3 ай бұрын

    Walaikum assalam

  • @NaveedArshad-kj5pl
    @NaveedArshad-kj5pl2 ай бұрын

    Sir, how to contact I need your help.

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    2 ай бұрын

    7355543798 only cou

  • @mdjahidansari9806
    @mdjahidansari98063 ай бұрын

    Hvac ka course bhi saath me hota hoga sir karna hai

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    2 ай бұрын

    No

  • @ekhlaqueakelapatna1933
    @ekhlaqueakelapatna193312 күн бұрын

    Sir aap ka WhatsApp group hai sir

  • @khajaali7737
    @khajaali77372 ай бұрын

    Isko bhejo mere paas

  • @mdaabidhussain2287
    @mdaabidhussain228729 күн бұрын

    sir inveter ac mai splite ac or window ac ka kam krta hun or 1 bar kya hua kise karan se compressor ka kam rahe the tab compressor main likha hua tha 220 v ac or aap bol raha hai ki non inverter ac likha huta hai

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    28 күн бұрын

    Ham ne kabhi ye bola hi nahi Ham to ye bolte hain ki inveter ac pe inverter ac likha rahega Non inverter pe kuchh nahi ikha rahega

  • @huzefabidani7367
    @huzefabidani73672 ай бұрын

    Boxx drkh kar hi kese pta kre ki ac inverter he ya non inverter

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    2 ай бұрын

    Out door me pcb rahegi inverter me Aur likha bhi rahega

  • @rdxeditor073
    @rdxeditor0733 ай бұрын

    Sir online course h

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    3 ай бұрын

    Yes 7355543798

  • @khajaali7737
    @khajaali77372 ай бұрын

    Helo bhaiya ek window ac hai on inverter ohhh baar baar uska gass lek ho ja rha hai usko kise thik kare aur jaha se Belding karte hai naa wahaa se lek nhi hota hai kise aur jagah se lek ho jata hai kaise thik kare😂😂😂😂

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    2 ай бұрын

    Pipe spire ho gayi hogi

  • @nirajsahuasansol
    @nirajsahuasansol3 ай бұрын

    R22, 2030 k bad totally band, new ac me r22 refrigerant nhi hoga

  • @sumitgaming9564

    @sumitgaming9564

    3 ай бұрын

    R 32 hoga

  • @mdaabidhussain2287
    @mdaabidhussain228729 күн бұрын

    Godrej campany ka splite ac the

  • @786_sameer
    @786_sameer3 ай бұрын

    सर आपका कॉन्टेक्ट नंबर चाहिए

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    3 ай бұрын

    7355543798 only course enquiry

  • @786_sameer

    @786_sameer

    3 ай бұрын

    सर आपसे बात करनी है

  • @Thesahilvlog-sf4pk
    @Thesahilvlog-sf4pk2 ай бұрын

    Sir number snd me

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    2 ай бұрын

    7355543798

  • @user-rm3no5lk1y
    @user-rm3no5lk1y3 ай бұрын

    Sir split AC shifting ke time gas store kaise kare please bata do

  • @kareemtechnicalmind8172

    @kareemtechnicalmind8172

    3 ай бұрын

    Video bani hai

  • @user-rm3no5lk1y

    @user-rm3no5lk1y

    3 ай бұрын

    Link send karo sir

Келесі