Insulation Testing Fluke-1507 - Fluke Fridays - Episode 106

All Fluke Insulation Testers - www.amazon.com/shop/fridayswi...
Fluke-1507 - amzn.to/43G8wJX
www.fluke.com/en-us/product/e...
Fluke-1503 - amzn.to/3xesFeb
www.fluke.com/en-us/product/e...
Fluke-1587 FC - amzn.to/4cEzlCg
www.fluke.com/en-us/product/e...

Пікірлер: 22

  • @enriquealvarez2045
    @enriquealvarez204525 күн бұрын

    Thank you sir

  • @gazyoung8490
    @gazyoung84904 ай бұрын

    very good, thank you

  • @tracyzhang7999
    @tracyzhang799911 ай бұрын

    Very useful, and clear! Thank you

  • @randyboden6087
    @randyboden6087 Жыл бұрын

    Thanks for the 1507 tour! I just started using one. Suggest just taking one reading to ground though. The winding continuity was proven in the first test. If there is a ground, it will be on all of them.

  • @jimmybarnes2753
    @jimmybarnes27539 ай бұрын

    Dont touch them gator clips while that red light is on it will make tears run down your legs !

  • @markm0000

    @markm0000

    9 ай бұрын

    He did at 7:15? Did you break yours doing that?

  • @jasonfoster9118

    @jasonfoster9118

    8 ай бұрын

    It'll shock the pee out of you lol

  • @davidebiagi9941
    @davidebiagi99417 ай бұрын

    Thanks a lot, I thought mine was fried😂😂😂😂😂😂😂😂

  • @ChrisHVAC
    @ChrisHVAC10 ай бұрын

    How about a video with the 1507 testing hvac compressor in the real world?

  • @mikeadler434
    @mikeadler43411 ай бұрын

    👍👍

  • @josephstanio4219
    @josephstanio4219 Жыл бұрын

    Thanks for the Great video. Curious what would be an unacceptable ohm reading on the 500 volt meg test. Is it a motor specific value? Or is anything under 550 meg ohms not acceptable. Thanks

  • @fridayswithbrandon

    @fridayswithbrandon

    Жыл бұрын

    It is manufacture specific. But the main rule of thumb is you want them all to be very close. If one is different you probably have a problem

  • @chrissanchez6675

    @chrissanchez6675

    10 ай бұрын

    From my factory training, FANUC motor spec is anything above 100Mohms is good. Anything below and you could start to cause damage servo amplifiers

  • @luckydiaz5479
    @luckydiaz54796 ай бұрын

    Ser, question for voltage test. How to change from Vdc setting to.Vac? Is it automatically change over while testing on AC voltage?

  • @fridayswithbrandon

    @fridayswithbrandon

    6 ай бұрын

    The insulation testers only output DC voltage. You can test an AC system but it will be with DC Voltage out of the meter. If you wanted to put AC voltage to test a system you would need whay they call a high pot tester. Fluke does not make this type of tool.

  • @ResuelveFilms
    @ResuelveFilms4 ай бұрын

    I have a question. If I’m trying to megger a 480v 3phase motor, should I use 500v or 1000v for the insulation test?

  • @fridayswithbrandon

    @fridayswithbrandon

    4 ай бұрын

    I've heard in the industry most will do twice the operating voltage. Thus 1000v

  • @TheEspinoza-hf1xf
    @TheEspinoza-hf1xf14 күн бұрын

    What happens if a 3ph compressor fails the insulation test???

  • @fridayswithbrandon

    @fridayswithbrandon

    14 күн бұрын

    @@TheEspinoza-hf1xf it could indicate it will stop working very soon or it's already no longer able to run. As far as how to repair it would need to be replaced or sent to motor shop for re-winding.

  • @H.A..
    @H.A..9 ай бұрын

    5.5 Mega Ohms??!!! are you sure that wasn't 550 Mega?

  • @fridayswithbrandon

    @fridayswithbrandon

    9 ай бұрын

    Not sure

  • @H.A..

    @H.A..

    9 ай бұрын

    @@fridayswithbrandon Yeah bro, I think it was 550 Mega, but I could be wrong. Thanks for the post, it's great.