Installing bridging

In this video I explain the installation of bridging in a floor system. This includes solid and cross bridging.

Пікірлер: 45

  • @shawnn6926
    @shawnn6926 Жыл бұрын

    My house was built 2 years ago with I-beam floor joists. The span is 16' and it's a little bouncy. I installed 2 rows of X bridging spaced evenly after watching your video and notice a huge difference. Thanks.

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    Жыл бұрын

    Glad I could help

  • @nbco55

    @nbco55

    4 ай бұрын

    I think you forgot an e, or you're giving your floor a big hug. ;)

  • @shawnn6926

    @shawnn6926

    4 ай бұрын

    @@nbco55 Yup. Thanks. I think I fixed it now.

  • @larrythebarberman
    @larrythebarberman4 ай бұрын

    Added cross strut to floor joist today, to replace one I took out, to add recess spot light underneath the original strut - now I fully understand what they do, and super glad I did not skip doing it

  • @organogold8
    @organogold88 ай бұрын

    Thank you so much for the information!! I appreciate it 😊

  • @alexaskey2240
    @alexaskey22408 ай бұрын

    Excellent video, Tim! I have weak points in my flooring due to over-spanned joists and will be installing bridging to secure the floors. Thank you very much!

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    8 ай бұрын

    Glad it helped you

  • @shawnsmith1905
    @shawnsmith1905 Жыл бұрын

    There we go. I'll be bridging the joists.

  • @michaelsuggett710
    @michaelsuggett710 Жыл бұрын

    Hey Tim, during the installation of our HVAC system, they knocked out a bunch of cross bridges to get the round air duct in. There is no room now for a 2x10 or a new cross bridge to go in its place. Is there anything you can do? You might be able to fit a 2x4 under the air duct, but that's about it.

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    Жыл бұрын

    That is what your going to have to do. Put the 2 x 4 across the bottom.

  • @michaelsuggett710

    @michaelsuggett710

    Жыл бұрын

    @@timpalmer-logstolumber1999 Awesome! I can work on that. It is good knowing that I can use a 2x4, it is hard to find stuff online.

  • @eltonnoway7864

    @eltonnoway7864

    Жыл бұрын

    Check out the KZread video title: How To Remove Bounce From Floor - by Shell Busey (Its old but shows the HVAC ducts issue and loss of bracing )

  • @jzeman
    @jzeman Жыл бұрын

    Does cross briding need to run the full length?... I have joist spans filled with ducts where the briding is interrupted.. not enough room for a brace

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    Жыл бұрын

    It should, if the duct work is in the way you could add blocking under the duct. If it is new construction you could ask the building inspector, codes vary by location.

  • @Kris-82
    @Kris-8210 ай бұрын

    so if you have floor 20ft x 8ft, and joist are running along the longer side how you bridge them? you cross the underneath horizontally in contrast to what you draw @1:46 - vertically?

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    10 ай бұрын

    If the joists are 20 feet long you would need 2 sets of bridging no more than 8 feet apart. You can use cross or solid bridging. If subfloor is already in use solid bridging.

  • @brandonvanetten8134
    @brandonvanetten81346 ай бұрын

    I have the metal x shape but can still feel bounce in the floor. And squeak.

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    6 ай бұрын

    You can install more bridging, solid bridging would probably work best

  • @XLongBeach
    @XLongBeach Жыл бұрын

    I have a really bouncy floor in my kitchen and want to do cross bridging will I have to just do it under my kitchen or all across the house

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    Жыл бұрын

    The code says anything over 8 ft should have it but if your kitchen floor is the only bouncy one I would only do it

  • @snomisdivad
    @snomisdivad20 күн бұрын

    Im building a 24'x24' cabin with a lvl at 12'. Im using 2"x10"x12'' for my floor jiost, 24"oc. Where would I put the bridging at? 6'?

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    19 күн бұрын

    Yes, that would be the best place

  • @markcarlock9756
    @markcarlock9756 Жыл бұрын

    We found mice had gotten into the Crawlspace due to previous owners not paying attention. We removed all the insulation when the crawlspace was encapsulated. This exposed the fact that the bozo's installing the batt insulation between my floor joists had disconnected the metal floor braces instead of cutting the batts to fit between them. What's the best way to return the structural integrity to the floor joists? Attempt to re-install the metal braces or install blocks?

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    Жыл бұрын

    Check to see if floor is level, if level or real close just reinstall metal bracing. If sagging you could try to jack it up then reinstalling bracing.

  • @markcarlock9756

    @markcarlock9756

    Жыл бұрын

    @@timpalmer-logstolumber1999 Thank you!

  • @rafaelLacerda646
    @rafaelLacerda646 Жыл бұрын

    If my room is 11ft wide would one row of bridging down the middle help make the floor stiff

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    Жыл бұрын

    Yes, that would help

  • @smjohn4640
    @smjohn46408 ай бұрын

    What if the subfloor is already installed? Can i use cross bridging? I'm a new homeowner and my kitchen floor feels like a trampoline.

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    8 ай бұрын

    If you have access you can install it after the flooring has been installed

  • @TV-hp9ro
    @TV-hp9ro Жыл бұрын

    What options are there if no bridging installed. Can you add later?

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    Жыл бұрын

    You can always add bridging later either cross or solid if you have access

  • @dlatt-kx5ir
    @dlatt-kx5ir3 ай бұрын

    I had foam insulation installed in my crawlspace, so almost impossible to install any bridging. Should I follow the 2x4 method and brace underneath the joists?

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    3 ай бұрын

    Did you use open or closed cell foam? The closed cell has some rigidity to it, open cell does not. Adding any bracing would help with bouncing or bowing floor.

  • @dlatt-kx5ir

    @dlatt-kx5ir

    3 ай бұрын

    @@timpalmer-logstolumber1999 It is closed cell foam, but does not completely fill the joist -- I never checked after they were done. So, do you think if the joists are completely filled there might not be any bounce?

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    3 ай бұрын

    @@dlatt-kx5ir I think most of the bounce would go away if they were full

  • @TheMcMeow
    @TheMcMeow Жыл бұрын

    When installing cross bridging instead of using nails can you screw the pieces from either side of the floor joist?

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    Жыл бұрын

    It is usually recommended that you nail or screw through the board you are attaching into what you are attaching it to. If that is not accessible, attach as best you can.

  • @davidbell5553

    @davidbell5553

    Ай бұрын

    Nails can bend but screws are hardened and will snap. Use nails.

  • @JR-xi2bh
    @JR-xi2bh Жыл бұрын

    So which is best

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    Жыл бұрын

    I prefer solid, no deflexion in it, easier to install

  • @zachary3777

    @zachary3777

    Жыл бұрын

    The crossed bridging will be stiffer, because you are basically making a truss structure, where the force is inline with the grain direction. The solid blocking carries a shear force, but you can still consider it equivalent to the x shaped path for tension and compression, but misaligned to the grain direction.

  • @avgjoe-cz7cb
    @avgjoe-cz7cb Жыл бұрын

    (True below, speak up.) BUT, do not, not do this. Install the bridging like he said, nail on top and do not nail the bottom yet. install your sublfoor and any walls during the build. Once the Dead load is established and before the Live load begins, THEN nail the bottoms of the Bridging. therefore a load on a single joist is spread out two joists on BOTH sides of the load. Think piano leg. So in effect, five joists are carrying the piano leg. Forget solid bridging unless it is over a carrying beam or girder. And use construction glue under the subfloor on the joist. Pay attention to his spacing regarding the run. F--k the Draftsman that forgets these important details. If you are a heavy person and hear squeaks coming from the floor years later, well, now you know...

  • @timpalmer-logstolumber1999

    @timpalmer-logstolumber1999

    Жыл бұрын

    You are correct about the load being applied before nailing the bottom. As far as using solid bridging it comes to two things, codes and preference. Always check local building codes. And yes always use liquid nail when laying subfloor.

  • @MrMalzers
    @MrMalzers2 жыл бұрын

    Speak up

Келесі