Installing a Hardwire EV Charger Myself [Maxoak]

Тәжірибелік нұсқаулар және стиль

Get this 50A EV Charger here: shrsl.com/4i8rw (6% off code: EarthDay)
Or on Amazon here: amzn.to/472XGhp
A hardwired EV charger allows you to go higher in amps which translates into faster charging. Sometimes you just want it to charge as fast as possible when you get back from a trip and you and something else to do back to back. Not that for hardwired installations, you still need an electrician to help you install the wiring to a box. Even connecting it to the box requires some precautions and knowledge of electrical hazards. Complete at your own risk!
That said, this is a great home EV charger that does what it says it will do, which is to charge continuously. My Tesla was only able to charge at up to 48A but this is not a limitation of the charger but that of the car.
Don’t beat around the bush, beat the bush!
I enjoy a good discussion but I like getting to the point even more.
► More resources at my Patreon: / beatthebush
► Mint Mobile, as low as $15/month: mintmobile.com/bush
► Moomoo, get up to 15 FREE stocks: Terms and conditions apply j.moomoo.com/008UFx
► Webull, up to 12 FREE fractional shares: bit.ly/2XwlcQ4
► Get $30 when you spend $30: www.rakuten.com/r/FRANCI7350?...
► FREE Audible Audio Book: bit.ly/2Z4RrN7
► Build Credit w/ NO Credit by Self-Lending: self-lender.3qcw.net/YYZBP
► BeatTheBush Honey Badger T-shirt: bit.ly/2FBAeLA
Watch my other videos at:
amazon.com/shop/BeatTheBush
/ @beatthebush
/ @beatthebushdiy
/ @beatthebushtech
/ @beatthebushfoodntravel
Keep up with me at:
/ thebeatthebush
/ thebeatthebush
/ beatthebush
WARNING & DISCLAIMER:
All published content is for informational purposes only, and any opinions expressed are our own.
BeatTheBush nor his representatives will offer you investment advice, investment services of any kind, and/or legal services. Please contact the appropriate licensed professional for such needs.
BeatTheBush nor his representatives will ask you for any private banking or investment account information. Please safeguard your data against criminal impersonators. Beware of scams often portrayed with misspellings of the social media accounts requesting transfers of digital currencies.
Copyright 2014-2023 BeatTheBush. All right reserved.

Пікірлер: 18

  • @user-ev2qo1hj1g
    @user-ev2qo1hj1g4 ай бұрын

    Ex journeyman lineman here, you did a good job! Even opening the breaker before inserting it is good safety practice. No sparks and no arcs good joo joo. (: As you said the size of the cable can be misleading due to insulation variances. And like you mentioned you are wanting to know the cross section of the actual wire and the make. Copper aluminum etc etc! I like you mentioned proper shoes as well. It amazes me that some people will even be standing in water or leaning on something being a good ground while working with electricity. Or not realizing the dangers of an open neutral that is not connected or properly bonded.

  • @BeatTheBushDIY

    @BeatTheBushDIY

    4 ай бұрын

    Thanks for your comment! It means a lot! =D

  • @jmgraydz

    @jmgraydz

    3 ай бұрын

    I mean as long as you don't count the use of a 70 amp rather then a 60 amp. Second those disconnects are known to literally melt with evs because of heat over time. I would suggest switching to a better disconnect and a 60 amp breaker....

  • @cgutowski471
    @cgutowski4712 ай бұрын

    There have been documented fires using that type of disconnect box, they are not rated for continuous high amperage of EV charging. You need replace with a lever handle disconnect.

  • @BeatTheBushDIY

    @BeatTheBushDIY

    2 ай бұрын

    Great suggestion.

  • @4252applebee
    @4252applebee2 ай бұрын

    i would not go beyond a 50 amp breaker even on a 200 amp panel maybe a sub panel yes ! what app are you using to the measure the heat can you share the link

  • @BeatTheBushDIY

    @BeatTheBushDIY

    2 ай бұрын

    kzread.info/dash/bejne/i3562cWflJrTpLg.html

  • @PoetWarrior1973
    @PoetWarrior19733 ай бұрын

    Can you leave a link to the connection box you use?

  • @BeatTheBushDIY

    @BeatTheBushDIY

    3 ай бұрын

    I think it was a Home Depot product, no link for that.

  • @4x2-ev
    @4x2-ev3 ай бұрын

    As a licensed electrician that installs EVSEs, I need to make a couple comments. First, always get a permit and inspection. Most areas require them and it your utility offers rebates they will need the inspection as well. This will not pass inspection. When using the 6/3 romex, I will fail inspection with anything more than a 50amp breaker (and set the charger at 40amps max). If I want to go to a 60amp breaker and the charger set at 48 amps, I need to use thhn in conduit or #4 romex. The 70amp is too big. Also, I will only mount units or cord holders to a stud. The best anchors will not last with the cord use.

  • @BeatTheBushDIY

    @BeatTheBushDIY

    3 ай бұрын

    Thanks for your comment! It makes total sense. I assume 4 awg is needed to minimize heating so you wouldn't need a conduit in that case. If you use 6 awg, it needs to be thermo plastic high heat resistant nylon coated wire (THHN) so that it can get hot if it needs be and inside the conduit.

  • @4252applebee

    @4252applebee

    2 ай бұрын

    Agree I would not go beyond a 50 amp breaker even on a 200 amp panel having solar and AC on my house, I have question if any electrician cares to answer the question , How long do these EVSE chargers last ? I have a AeroViroment 32 amp charger on a 40 amp breaker hardwired installed "9 "years ago still going strong I use it now for my Model Y 2023, should I replace ?

  • @IAmThePrepper
    @IAmThePrepper6 ай бұрын

    Tesla only supports to charge max up to 48A.

  • @BeatTheBushDIY

    @BeatTheBushDIY

    6 ай бұрын

    Yeah.. when charging via AC, max is 48A

  • @timnevitt2993
    @timnevitt29933 ай бұрын

    i have seen melt downs on that disconnect box, should use a lever handle disconnect

  • @BeatTheBushDIY

    @BeatTheBushDIY

    2 ай бұрын

    More beefy, good idea. Where did you see the melt down? Might be from a bad connection resulting in overheating.

  • @timnevitt2993

    @timnevitt2993

    2 ай бұрын

    @@BeatTheBushDIY video on youtube

  • @timnevitt2993

    @timnevitt2993

    2 ай бұрын

    @@BeatTheBushDIY state of charge