HVAC (Heating, Ventilation, Air Conditioning) TRAINING BOARD: How To Check A Low Voltage Thermostat With A MultiMeter Using Voltage/Volts/ 24VAC (Thermostat Troubleshooting Tips) How to check a thermostat with a multimeter/Thermostat troubleshooting with a multimeter/Thermostat troubleshooting/Honeywell thermostat not working/Thermostat Honeywell not working/Thermostat not turning on AC/Thermostat not turning on heat/Is my thermostat bad/Thermostat Diagnosis/Nest Thermostat Not Working/How Does A Thermostat Work/Thermostat Working Animation/Honeywell Wifi 7-Day Programmable Thermostat/Honeywell T9 Smart Thermostat/Honeywell Wifi Smart Color Thermostat/Honeywell T6 Pro Thermostat/Honeywell Vision Pro 8000 Wifi Programmable Thermostat/Honeywell Focus Pro Wifi Programmable Thermostat/Honeywell D6 Pro Wifi Ductless Controller/Honeywell Vision Pro 8000 With Redlink Technology/Honeywell Pro 1000/Honeywell Pro 2000/Honeywell TH4110B 5-2 Programmable Thermostat/Honeywell Pro 3000/Honeywell T1 Thermostat/Honeywell T4 Pro Thermostat/Honeywell Home/Honeywell T10 Pro Smart Thermostat With Redlink Room Sensor/Honeywell Round Non Programmable Thermostat/Honeywell T5 Smart Thermostat/Honeywell Touchscreen Thermostat/Honeywell RTH6350D1000/U/Honeywell RTH2410B1019/E1/Honeywell RTH111B1024/E1/Honeywell RTH221B1039/U1/Honeywell RTH6360D1002/E/Honeywell RTH5160D1003/E
=================================================
VIDEO LINKS BELOW
How To Troubleshoot A Transformer
• HVAC Training Board: H...
=================================================
LINKS TO TOOLS USED IN THIS VIDEO
Fluke 902 FC HVAC True-RMS Clamp Meter
amzn.to/39wvwiK
=================================================
A thermostat is a regulating device component which senses the temperature of a physical system and performs actions so that the system's temperature is maintained near a desired setpoint.
Thermostats are used in any device or system that heats or cools to a setpoint temperature, examples include building heating, central heating, air conditioners, HVAC systems, water heaters, as well as kitchen equipment including ovens and refrigerators and medical and scientific incubators. In scientific literature, these devices are often broadly classified as thermostatically controlled loads (TCLs). Thermostatically controlled loads comprise roughly 50% of the overall electricity demand in the United States.
Digital thermostats use a simple device called a thermistor to measure temperature. This is a resistor which allows electrical resistance changes with temperature. The microcontroller in a digital thermostat can measure the resistance and convert that number to an actual temperature reading.
A digital thermostat can do a few things that a regular mechanical thermostat cannot. One of the most useful features of a digital thermostat is programmable settings. In the winter, you can program it to automatically turn up the heat for an hour or two in the morning while you get ready for work, turn down the heat until you get home, turn up the heat in the evening and then turn down the heat while you sleep. This is a great money-saving feature because you can simply turn down the heat when it isn't needed.

Пікірлер: 29

  • @gohan192
    @gohan1922 жыл бұрын

    Thank you, as a HVACR apprentice I wasn't sure about the second method between common and control wires but now you have clear up my confusion.

  • @jollyscaria1922

    @jollyscaria1922

    11 ай бұрын

    G fan w hoeting c come 24 v c coman y cooling r .rc 24v

  • @harrybaldo3320
    @harrybaldo3320 Жыл бұрын

    Man I can't thank you enough ! I have worked in the field and this is the absolute best knowledge on an explanation on how to make you finally understand the low voltage circuit and how common actually comes into to the checking vs red constant .thank you extremely well done 👏

  • @izzybell11
    @izzybell112 жыл бұрын

    I love tutorials. Well explained. Great job JMT

  • @mariovasquez4727
    @mariovasquez47273 ай бұрын

    Great job very professional thank you sir.

  • @JumpermanTech

    @JumpermanTech

    3 ай бұрын

    Thank you very much! Stay tuned for new videos every week🔧⚡️

  • @manonfire3642
    @manonfire36422 жыл бұрын

    Invaluable channel. Thx for sharing.

  • @JumpermanTech

    @JumpermanTech

    2 жыл бұрын

    You're very welcome & thank you very much! Appreciate you watching & commenting 🙏 Stay tuned for new videos every week🔧⚡️

  • @rjrandolph8256
    @rjrandolph82565 ай бұрын

    Got a question for you I got the smart thermostat and I don't have a clue how to wire it up I have a red blue white and green wire but it doesn't say anything on the back of it where it should go I think I might be able to send a picture I'm not sure

  • @toyinorodare4072
    @toyinorodare40722 жыл бұрын

    Thank you for the Update.

  • @JumpermanTech

    @JumpermanTech

    2 жыл бұрын

    You're very welcome!

  • @thesilentonevictor
    @thesilentonevictor2 жыл бұрын

    Great job tech jmt always a pleasure 🙏

  • @JumpermanTech

    @JumpermanTech

    2 жыл бұрын

    Thank you brother! Always! 🙏🤙🔧⚡️

  • @edalman3896
    @edalman38962 жыл бұрын

    Thanks jumper man tech for so valuable informatio

  • @JumpermanTech

    @JumpermanTech

    2 жыл бұрын

    You're very welcome & thank you! I appreciate you watching & commenting. Stay tuned for new videos every week🔧⚡️

  • @Du_It_at_Home
    @Du_It_at_Home Жыл бұрын

    Very helpful. Thanks a lot.

  • @Sc19869
    @Sc1986910 ай бұрын

    Why when the switch is open is all the voltage on the switch, but when circuit is closed why does it drop to 0. Thanks for your videos.

  • @migueldominguez4311
    @migueldominguez4311 Жыл бұрын

    Man . Your videos are great Wish you can do translate to Spanish thanks 😊

  • @veter_kg
    @veter_kg Жыл бұрын

    What if I have 9v between Y AND C? Thermostat working on Cooling. Outdoor unit not turning on. Same thermostat working properly with another Air conditioner. Btw problem was with transformer. We replaced transformer, but he just died again in 30min. But during this 30mins outdoor unit didn't turned on

  • @Eddy63
    @Eddy632 жыл бұрын

    Great explanation ... I have no idea what Ledferd Katiefu said but I think I agree ... Lol ...

  • @manonfire3642

    @manonfire3642

    2 жыл бұрын

    He said 'mucho gracious'.

  • @migueldominguez4311
    @migueldominguez4311 Жыл бұрын

    Good job very explaining Could be great if you translated to Spanish

  • @duaneward925
    @duaneward925 Жыл бұрын

    I have done so much research on my stinking furnace I really am losing the energy to look up the fluke besides I don't have one and am try to save money fixing this thing myself I can't go out and buy one. I do love your mock control board. It's a great vid. I'm just so incredibly frustrated because I cannot find the problem with my furnace. So far everything has checked out. It simply seems likefd gas is turned off the unit. But it can't be. I hear, and even feel, the click in the gas control valve. Bit there is no gas. I'm about to remove the gas line to be 100% certain about the gas line to the furnace is really live. If it is I guess I will start over with testing the control board with a multimeter. But I hear the click in the gas control valve. Can it click and still be stuck. And then click again when it should turn off and still be stuck? Can anyone give me some ideas on this? Thanks if you can. And thank you for you vids.

  • @duaneward925

    @duaneward925

    Жыл бұрын

    I guess this channel isn't monitored any longer.

  • @archiesatera-mf3iy
    @archiesatera-mf3iy Жыл бұрын

    Nice theory very clear thank u sir 👍👍🫶🫶🫶

  • @shine-cg9uf
    @shine-cg9uf2 жыл бұрын

    👍🇺🇸💪❄

  • @JumpermanTech

    @JumpermanTech

    2 жыл бұрын

    Thank you!! 🙏🤙🔧🇺🇲

  • @ferrnnygarcia8523
    @ferrnnygarcia85232 жыл бұрын

    Open circuit reads 0.0 closed gives your your voltage you saying it backwards

  • @mlindysay

    @mlindysay

    Жыл бұрын

    No, he is measuring in reference to the 24V in line, not ground. Closed gives you your power, not voltage. Then the relay closes there is now power in that line, but it is the same 24V. So 24V - 24V = 0V. Voltage is the difference in potential. The 24V measured when the relay is open is the potential for power to flow if the two lines were connected.