Here’s an important factor that most technicians overlooked, compressor oil levels, some compressor has oil level sight glass and others the only way to check oil levels is to disconnect it from the system and drain all oil contents. In this video the compressor has a oil sight glass and typically the level should be between 50 to 75% of the glass. Also information about compressor oil will most likely be on its name tag.
Пікірлер: 66
Fantastic video; benefiting from this 3 years later. God bless
@D2DNYAC
Ай бұрын
Thanks for watching
Nice video. Thank you for the info.
Very informative, I thoroughly enjoyed the narration! Thanks
@D2DNYAC
2 жыл бұрын
Thanks for watching friend
That must have a bad plug heater, I didn't see a crank case heater. That foaming is from liquid refrigerant getting under the COOL oil when the system is off. Then when it start's it pushes the oil out into the system. The heater helps to prevent that by keeping the oil HOT.
Thanks for the detailed explanation
@D2DNYAC
11 ай бұрын
Thanks for watching
Sir please discuss me aproch temperature on air cool chiller. Water cool chiller aproch temperature vs aircool chiller aproch temperature.
👌👌
Looks like someone was struggling with those braze joints.. :-)
@D2DNYAC
3 жыл бұрын
Indeed 😂 that’s why I took over
@sjefoekel6058
3 жыл бұрын
@@D2DNYAC also something dripping from discharge line.
on a typical 2 ton older r22 unit how much oil approximately for system? 25000 btu system.?
@D2DNYAC
2 жыл бұрын
@ron hanish Hard to say if the compressor doesn’t have an oil sight glass, you should be able to determine the oil type and quality from the name plate on the compressor! Or by using the compressor make, model and serial through the manufacture! Or by using the equipment make model or serial and contacting the unit manufacturer
@richardromero1736
Жыл бұрын
Install a side glass on it
I can't figure out what you are doing!!! Thanks anyway!
Me too Hvac ✋ tech.
I have a question- I have a rheem system. The compressor runs fine when temps outside are in the upper 70s, but once temps are in the mid 80s the compressor will run for a while and then shut down. The air handler is still blowing air. I’m assuming the scroll compressor is going into protection mode. Could old oil or warm out oil cause this issue? Thanks!
@D2DNYAC
Жыл бұрын
How is your refrigerant charge?
@bigkidband5731
Жыл бұрын
@@D2DNYAC good
@D2DNYAC
Жыл бұрын
Is the compressor over heating?
@bigkidband5731
Жыл бұрын
@@D2DNYAC I’d assume, but not sure. I ran it yesterday when it was 85 outside. Ran fine for half the day then compressor shut down. It’s 75 degrees out side right now, so I turned on the ac. Had to go out and push the reset button on the compressor. Been running fine for an hour.
@D2DNYAC
Жыл бұрын
Ooh, what button are you resetting?
So oil should be until half of glass When compressor working or when compressor not working
@D2DNYAC
2 жыл бұрын
Not working!
How to change oil in rotary compressor?
@D2DNYAC
3 жыл бұрын
If it’s hermetically sealed with no oil port at bottom of compressor, then Recover the refrigerant disconnect the pipe and drain it through suction pipe and add it back through suction pipe of compressor , the amount and type of oil should be on the sticker on the compressor.
Real yardy
if a compressor seizes due to being low on oil, what's the next step?
@D2DNYAC
Жыл бұрын
Replace the compressor
@aldwinmacatbag2295
3 ай бұрын
@@D2DNYACdo need to flush the system when replacing a sieze compressor?
I have 1.5 hp split a/c system, the compressor gets too hot after half an hour, current goes up to 10 amps, then the compressor shut down, how do I fix it?
@D2DNYAC
3 жыл бұрын
If it’s actually pumping / running check and verify the electricals power supply etc is good if so, if head pressures is not high, then compressor is bad, it will probably fail a Meg test. If it doesn’t run /pump try using a hard start kit if it doesn’t run then the compressor is bad
@mamaspuput8860
3 жыл бұрын
@@D2DNYAC the head pressure is good, when its off, the pressure is around 250-300psi, and when its pumping, the pressure is around 140.
@mamaspuput8860
3 жыл бұрын
what is meg test
@D2DNYAC
3 жыл бұрын
What refrigerant?
@mamaspuput8860
3 жыл бұрын
@@D2DNYAC r32
Danfoss compressor oil in sight glass There is no fluctuates during operation. Please advise what is the issue
@D2DNYAC
2 жыл бұрын
Hey friend I don't understand what you are asking!
@vigneshwaran6638
2 жыл бұрын
@@D2DNYAC Dear.. The danfoss compressor is running. But the oil is ideal in sight glass.
@vigneshwaran6638
2 жыл бұрын
@@D2DNYAC Oil no circulation during operation. Please let me know what is the problem
@D2DNYAC
2 жыл бұрын
Oil problems is usually a result of 3 things , low back pressures, low oil, faulty oil pump. So if you add oil to the proper levels while the compressor is off and then when you run the compressor the levels remains low its a oil circulation problem
@vigneshwaran6638
2 жыл бұрын
@@D2DNYAC thank you Dear.. 😊
Show how to troubleshoot a compressor
@D2DNYAC
3 жыл бұрын
kzread.info/dash/bejne/q451ycpqf5O1hqQ.html
sir how to add oil to compresor you can referensi vidio
@D2DNYAC
3 жыл бұрын
ADDING OIL TO HVAC / AC COMPRESSOR
@susantoresas
3 жыл бұрын
@@D2DNYAC ac kompresor same your this vidio
@D2DNYAC
3 жыл бұрын
kzread.info/dash/bejne/Z5qjt6qmeajaiZc.html
@D2DNYAC
3 жыл бұрын
Click the link to see me adding oil
Those welds look like shit. Yep Its leaking.
@D2DNYAC
2 жыл бұрын
lol 😂 yea indeed they do