How to wire the Mixergy Tank to Daikin Monobloc Heat Pump

Want to know how to wire the ‪@mixergyltd6286‬ Cylinder to the ‪@DaikinUK‬ Monobloc heat pump, watch this video.
Emilie explains all the connections and how to use the system.
We have shown schematic pipe and wiring drawings, however please read the instruction provided with your Mixergy Tank.
Watch our Full ‪@DaikinUK‬ High capacity Monobloc Video, please see link • Daikin Monobloc Heat P...
‪@ecobubl‬ stock both Daikin and Mixergy cylinders and accessories, we cover the whole of the UK.
www.ecobubl.co.uk - Tel: 01985 208209

Пікірлер: 20

  • @fidelischidozieinyiama1176
    @fidelischidozieinyiama11768 ай бұрын

    Great teaching

  • @Rosshumpo
    @Rosshumpo Жыл бұрын

    Seems like you made this just for us as we fitted this exact system today.. vary helpful ,thanks guys

  • @ecobubl

    @ecobubl

    Жыл бұрын

    Cheers Ross 👋👍😀

  • @gaycha6589
    @gaycha6589 Жыл бұрын

    Great technical presentation and content V informative, thank you. For us seniors, are these fit and forget installs, or do we need tech savvy to adjust for HP vs PV input priority to the tank winter/summer etc? Also, are these suitable for hard water areas - do they need descaling etc to keep efficiency? Very impressed!

  • @ecobubl

    @ecobubl

    Жыл бұрын

    Thank you for your lovely comments. The Mixergy app is very homeowner user friendly.

  • @lazyade
    @lazyade7 ай бұрын

    Great video. I have a Daikin Altherma 3 with a buffer tank and separate CH circulation pump, the system was installed with Hive controls (wish I’d gone with Madoka), but Hive seems to be the only control of the circulator pump. As an example, the circulator pump stays on when the DHW is heating. I’m thinking of moving to Homely controls which will mean removing Hive, but what then controls the circulation pump? I would have thought there would have been a volt free contact in the Daikin unit for the circulator pump, but looking at your wiring info that doesn’t appear to be the case.

  • @BruceBrendon
    @BruceBrendon Жыл бұрын

    😍

  • @martingardner9885
    @martingardner9885 Жыл бұрын

    I'm not an installer but thank you for this, its an interesting video. If you were looking at getting an Air Source Heat Pump would you recommend getting a Mixergy Tank over the manufacturers cylinder? In this case it would be Daikin.

  • @ecobubl

    @ecobubl

    Жыл бұрын

    Hi Martin Thanks for your lovely comments. Yes would definitely recommend Mixergy over manufacturers cylinders, gives you so many options, with connecting Solar, heat pump and direct electric.

  • @mattmackenzie1111
    @mattmackenzie1111 Жыл бұрын

    Could you explain the benefits of the cylinder, the only advantage I can see is that you could heat a small amount of water during the day when electricity is most expensive? Would it not be cheaper to use heatpump to charge cylinder in this case? Cutting off heat pump cylinder sensor are you not allowing the heat pump to modulate having a negative affect on efficiency?

  • @jimmyslev
    @jimmyslev Жыл бұрын

    Hey - if the Daikin is receiving a false signal for HW, does that mean it's always fully charged and can't use the "heat 40% of the tank" for example, option?

  • @loz336
    @loz336 Жыл бұрын

    Was it a mistake to put the Live and Neutral in a single wago together or am i missing something simple, genuine question. I don’t want to blow anything up

  • @ecobubl

    @ecobubl

    Жыл бұрын

    Hi its not live and Neutral, its just a live, for a hot water tank stat that is not required with the Mixergy Direct cylinder, so you just link the 2 wires together.

  • @chriss4949
    @chriss4949 Жыл бұрын

    I have been “advised” that Mixergy do not work well with Vaillant ASHP.! I half-suspect that the person quoting just wants to steer me towards a standard cylinder and is telling tales. Any thoughts ??

  • @martintom7390
    @martintom7390 Жыл бұрын

    Hi, I looking for Firmware Update of my Daikin Altherma 3 M. Do you have any Information to do that

  • @ecobubl

    @ecobubl

    Жыл бұрын

    Hi Martin You a Daikin “D Checker” this cost us £300. And a laptop. If your an installer it can get the software from the Daikin portal. If not, you will need a Daikin engineer to do it. Cheers

  • @ecobubl

    @ecobubl

    Жыл бұрын

    @@zlmdragon. We are slowly creating more, Emilie is also very busy with the Fully Charged Show KZread channel (Everything Electric)

  • @kierank01
    @kierank0110 ай бұрын

    If it's possible to plug a connector in the wrong way round, frying a board, there is a design flaw. Simply shouldn't be able to plug it in wrong

  • @baybarshan2500
    @baybarshan2500 Жыл бұрын

    I love your videos I considering having a Daikin AIr to water heat pump installed on my existing heating/warm water system. Current radiators I have are about 20 years old Aluminium radiators, would you suggest to have these replaced as well ?

  • @ecobubl

    @ecobubl

    Жыл бұрын

    Hi Thanks for your comments. Yes I would advise replacing 20 year old radiators, so you have an almost clean new system.