How to test and replace a Fan & Limit Control

Тәжірибелік нұсқаулар және стиль

www.supercoolsliderule.com This video tutorial demonstrates how to test and replace a fan & limit control.

Пікірлер: 52

  • @balfour98
    @balfour9810 жыл бұрын

    Nice Rolex Thanks for the tutorial

  • @ahmedfaraz11
    @ahmedfaraz116 ай бұрын

    Thank you so much for your video, I was able to check how to check my fan limit switch. it was really helpful.

  • @vincentpadalino8003
    @vincentpadalino80038 жыл бұрын

    I thought it was a great video. Very helpful

  • @jimbola77
    @jimbola777 жыл бұрын

    thank you for sharing!!!!

  • @KPSoutside
    @KPSoutside5 жыл бұрын

    Do you happen where the limit switch would be in a older Lenox gh5 series furnace?

  • @drepoin6406
    @drepoin640611 жыл бұрын

    Great video, but would like to know what model fieldpiece meter you were using. Does it have a low +/- range? I have been looking to move away from the Fluke meters.

  • @warrior7772
    @warrior77729 жыл бұрын

    Just because the the limit switch checks out electrically with the meter doesn't mean it's working properly. It may have a mechanical binding or its thermostatic control may have gotten mis-adjusted.

  • @joshuanorris9785

    @joshuanorris9785

    6 жыл бұрын

    warrior7772 how do you re adjust it? thanks

  • @scubasteve7323
    @scubasteve73239 жыл бұрын

    Could you send me a link to where I could buy that same limit switch?

  • @kleetus92
    @kleetus923 жыл бұрын

    How do you test if the switch is actually accurately operating on temperature?

  • @lentruthbetold7805
    @lentruthbetold78055 жыл бұрын

    Is the power on when you use your multimeter?

  • @miketaylor1356
    @miketaylor13562 жыл бұрын

    I have the same furnace won't turn on pilot light works but furnace won't turn on

  • @jamesgrapp1770
    @jamesgrapp17702 жыл бұрын

    My White-Rodgers limit switch 5D51-090, has a lever protruding from the cover. The lever moves from 'auto' to the center between 'auto' & 'manual' over a period of time. Fan runs continually and It then blows only cold air. I move the lever back to 'auto' and it works fine for several months or a year and then I have to move it again/ This has been going on for a couple years now. Otherwise the furnace works fine. Do I need a new limit switch?

  • @timtnr.6177

    @timtnr.6177

    Жыл бұрын

    Yes, I replaced a Honeywell fan-limit control from the 1950's it had a switch on the front cover, moving the switch back and forth the fan continuously stayed on in either mode it was set at

  • @mwb8246
    @mwb82469 жыл бұрын

    this guy really shouldve mentioned removing the brass jumper... sending 120v from the line side to the 24v control side will really ruin your day.

  • @sandrastan413
    @sandrastan4137 жыл бұрын

    i have replaced my thermocoupling, and have installed a new gas valve on my miller cmf80-AG the pilot works , but after i turn the thermostat up to where the furnace should kick on, the pilot goes out and doesnt light the furnace , would that be caused by the limit switch?

  • @mikemalone6103

    @mikemalone6103

    7 жыл бұрын

    Sandra Stan in a word, no. You may have a gas pressure problem or bad gas valve

  • @frankb2029
    @frankb20297 жыл бұрын

    We have a 22yr,. old Arcoair gas/pack on the roof, recently been having issues with blower not shutting down when the heater down cycles. Numerous times I had to shut the power off for some length of time, then it would work ok for all day.. I am assuming the problem could be with the limit switch or fan relay, I just hate to replace the whole unit unless I absolutely have to..

  • @oscarcephus6157

    @oscarcephus6157

    7 жыл бұрын

    Frank B

  • @313theman2011
    @313theman2011 Жыл бұрын

    What temp is the fan and limit supposed to be at?

  • @pollydor07
    @pollydor074 жыл бұрын

    Thanks

  • @vemlacduong1954
    @vemlacduong19548 жыл бұрын

    thanks .

  • @justdissin7340
    @justdissin73405 жыл бұрын

    After using my a/c fan blower motor stays running,doesn't shut off,i isolated thermostat & still runs,doesn't have a control board,30yr old york system

  • @Okikor1
    @Okikor16 жыл бұрын

    If it trips the high limit switch will it also cut power to the WiFi thermostat (no batteries)? When it happens, there's no voltage between R and C for about 45 seconds. What could it be?

  • @JBK63

    @JBK63

    9 ай бұрын

    In the normal wiring scheme yes it will. Things could be rewired in such a way that the high limits switch the energizes the gas valve but does not de energize the thermostat

  • @davemarm
    @davemarm9 жыл бұрын

    Why would you spin the dial by hand? That de-calibrates the temperature sensor. Don't be lazy. Do this the right way by turning on the furnace and make sure the temperature causes the contacts to close. Then turn off the heat and ensure that the fan is no longer powered after the temperature reaches the lower setpoint.

  • @timmyturner5088

    @timmyturner5088

    6 жыл бұрын

    Dave M Absolutely correct, that Is WHY the dial SPECIFICALLY READS CAUTION " Do NOT Rotate Dial" hold dial to set moving pointers"

  • @thegitago7823

    @thegitago7823

    5 жыл бұрын

    @@timmyturner5088 and this is why Im on this page.. because I have a fan limit switch that is SET to turn on at 150-160.. and it is turning on at 130ish.. no matter how i set it.. then it turns off 10degrees sooner than it should also... Trying to find a video I can watch that shows how it should properly work

  • @marcz9482

    @marcz9482

    3 жыл бұрын

    The furnace is outside not connected

  • @timtnr.6177

    @timtnr.6177

    Жыл бұрын

    @@thegitago7823 When I was 13 a technician came out to assess the furnace in the apartment we lived at. I watched the technician move the dial to check the fan on and fan off. I knew at 13 this would damage the limit control and told the technician to hold the dial and move the pointers. He said " it won't hurt it" and he learned the hard way the burners and fan were short cycling more after he left! Turns out the furnace had a badly cracked heat exchanger and the cracked heat exchanger was fooling the fan switch, cooling down the combustion chamber causing the fan switch to turn the fan off for about 50 seconds and then would kick the fan back on once the burners heated the plenum above 100°F

  • @deibertmichael
    @deibertmichael7 жыл бұрын

    What if it Goes on heats to temp. Turns off then goes on again for a minute then shuts off?

  • @ebookpioneers

    @ebookpioneers

    4 жыл бұрын

    That means this switch needs to be replaced.

  • @mikeyd19841
    @mikeyd198414 жыл бұрын

    My fan just keeps running for some reason? Any help.thanks

  • @timtnr.6177

    @timtnr.6177

    Жыл бұрын

    Either the switch on the thermostat subbase ( if you have one) marked "COOL" "OFF" "HEAT" , "FAN ON" " AUTO" make sure your fan switch is in AUTO position, if it is in "FAN ON" position will cause the fan to run continuously. Also some fan-limit controls have a fan and manual switch on them. Make sure the switch is set to Manual or the fan will continuously run if set to FAN mode. Honeywell fan-limit control usually you pull out or push in a white plastic knob on the front Cover. On a White Rogers fan limit control usually you slide the switch to the left or right to select the FAN or AUTO mode desired

  • @elvis57presley4
    @elvis57presley47 жыл бұрын

    though ful vid there but I have ithink the some trouble the fan do-its come on but the warm air doesn't there I replace ad cam stat l22-9a-11 limit switch too that doesn't work at all. its a 1973-4 rheem gas furn .. help ..

  • @scottc1861
    @scottc18619 жыл бұрын

    Dave, that might be hard considering this furnace clearly isn't hooked up to anything.

  • @HsingSun
    @HsingSun2 жыл бұрын

    Thank you for your video. Are you an AC guy, you dressed so nice, it doesn't look like an AC tech?

  • @deanmadge3816
    @deanmadge38164 жыл бұрын

    Cant really see where you put ur leads

  • @rubencastillo2623
    @rubencastillo26232 жыл бұрын

    How much 4the rolex?

  • @johnbipper4601
    @johnbipper46012 жыл бұрын

    I always get my gold watch scratched up when I do this...

  • @johnc4876
    @johnc48767 жыл бұрын

    Honeywell has instructions NOT to manually turn the limit dial.

  • @timtnr.6177

    @timtnr.6177

    Жыл бұрын

    Exactly the dial clearly is stamped "CAUTION" do not rotate dial. Hold dial when setting pointers

  • @tomcatranchblitz
    @tomcatranchblitz5 жыл бұрын

    42 seconds into this vid, he says "at 100 degrees the furnace will come on", that is wrong.

  • @ebookpioneers

    @ebookpioneers

    4 жыл бұрын

    Obviously. It's called a slip of the tongue. So what?

  • @pjazwier

    @pjazwier

    4 жыл бұрын

    Exactly. it turns off at 100. It turns on at 150 which is the second setting. This clip is all kinds of wrong.

  • @ihtegoogle1371
    @ihtegoogle13717 жыл бұрын

    keep your hands out of the way

  • @ajaxthree1
    @ajaxthree15 жыл бұрын

    Consider...no judging or complaining about another in their ability to communicate how to do something... always look for more knowledge; one will learn more this way and spend less time worrying about how another does a particular way... just a suggestion. No need to be critical of the person, however be critical in the performance of your work. There are master techs I have worked with who were not effective teachers. Here is one tech that I have learned a lot from. kzread.info/dash/bejne/nJtk0K1tga_WitI.html By the way...learn to not take things personal...it is easy to do, but studies show that what one thinks about another doesn’t really matter. Try to understand all the conditions involved in the particular situation you may find yourself in regarding HVAC. I have have learned to liken troubshooting or just performing maintenance on a unit, to a doctor performing surgery or giving a physical examination. Good thing the units I have worked on were not human beings. And it is a good thing there is one basic design on the human being... not so with HVAC units, however they all do the same thing...basically...push heat from point A to point B. Just a perspective.

  • @kj7816
    @kj78165 жыл бұрын

    If its working properly. Why are you taking it out.

  • @adamhg985

    @adamhg985

    4 жыл бұрын

    To show how to replace it numnuts

  • @jamessullivan9992
    @jamessullivan99922 жыл бұрын

    honeywell limit switch lasted 4 months brand new what a rip off.

  • @timtnr.6177

    @timtnr.6177

    Жыл бұрын

    They don't make em like they used to