How to service RO water filter / Reverse osmosis filter changing / Tamil.
Ғылым және технология
Video help you how to service and filter changing your domestic reverse osmosis water filter..
#Ro_Service
#Filter_Change
#Tamil
#Membarane
#InlineFilters
Пікірлер: 257
தமிழில் எதிர் பார்த்திருந்தேன் மிகவும் நன்றி.
Very clear explanation of ro service Thank you
நான் எதிர் பார்த ததை போல இருக்கு வயர் கனெக்சன் சூப்பர்.
Anna super video anna,enga vitla iruka water fliter repair nenga mathunadhala nanum mathuna enaku usefula irunthuchi anna inthaa video,supera anna theliva explain panni irukinga anna
👍Super sir Very nice demo
நல்ல பதிவு . RO ல என்னென்ன கம்ப்ளெய்ன்ட் வரும் அதற்கான தீர்வுகள் என்ன என்பது பற்றி விரிவான பதிவு போட்டோல் பலருக்கும் உதவியாக இருக்கும் .
Super video bro.....💐💐💐💐
Super video clear and useful.. thanks brother. Im a new sbcrber
ரெம்ப நன்றி அண்ணா
Thank you brother 🙏.
Useful information bro
Super bro Tks
Bro, the used membrane can be removed and use after some months? I was mistakenly purchased the new membrane. since my old one is working good. For testing, I have used the new one.
Thanks for video
Super bro
வெளியேறும் தண்ணிரை என்குடும்பத்தினர் ஒரு சொட்டு கூட வீணாக்காமல் பயன் படுத்துகிறோம் அனைவரும் இதை கடைபிடிக்க வேண்டிக்கொள்கிறேன்
@r2_tech_tamil
4 жыл бұрын
Super.. Thanks brother..
Super
Super g
Old solenoid valve sanlinix 36v DC SLC 2, same solenoid podanumaa bro, can I put solenoid valve HR1 herowater 36v DC, or 24v DC herowater ?
bro orru doubt..engha vitlaa hi rise tank illla..nan ippo purifier pota keela barrel thani vaicha athuvae intake panikuma illa..mela tank vachathan athu work aghuma
Suppers
Very good information brother awesome👌👌👌👌👌👍👍👍👍👍
Bro fr450 fr550 ethu ethukku Enna velai seiyum membrain 75 .80 ..85. 100.gpd evvaiku ethu sariyana fr sollunga bro
Nice bro, i have one doubt. Leakage from membrane water housing from top. Can you please help
@r2_tech_tamil
4 жыл бұрын
Change membrane L'bow connector.
👍
sir i tried with ur guidence. i replaced all the filter and conector. but when we run there is a leakge in all push fit conector
Bro In sediment filter and pre carbon filter arrow is showing? Which is the correct side
Bro reject water mattum varudhu... But product water fill aagala.. what will be the problem??
Water out nalla irukku but purifier water romba kammiya irukku bro. 4 periya kodam out la water vanthatha in la 15 litre water kedaikkuthu. Yenna problem ma irukkum?
Nice video sir, sir sediment filter la adikadi clog aaguthu so naa sediment filter illama direct ah pre carbon filter use pannalama please guide pannuga my area yellow water even though we have iron remover at terrace still sediment filter la adapu varuthu sir so direct pre carbon filter use pannalam rgds
@r2_tech_tamil
4 ай бұрын
Panalam.. But pre filter housing 2 add panikonga..
@kozhumamramamurthyseshadri2591
4 ай бұрын
Ok sir thanks
Excellent explanation.. bro I have a doubt, if we use 100gpd membrane, can we use fr 450 or we have to use fr 550.. I saw in a video that for 80gpd - 450 FR and for 100gpd - 550fr.. so please clarify... and another doubt if we 100 gpd capacity pump, and with that can we use 80gpd membrane? Or must have to use 100gpd membrane?
@paulsankar2185
3 жыл бұрын
Call NAMPAR PLEASE PRO
நன்றி. Pureit Ultima RO water purifier with oxy tube, இந்த மாடலுக்கு சர்வீஸ் கிட் GKK1 and GKK2 எங்கே வாங்கலாம். Pureit சர்வீஸ் கிட் ரொம்ப அதிக விலை.
0:15 this model name cruise illa bro.. dolphin 🙏😊
Bro..neenga use pandra brand lam 1st quality ah? 1 year ku gauranty kudukalama..
@r2_tech_tamil
4 жыл бұрын
Sorry.. Borther i don't know.. Na puthusa try panipathen.. Nalathan iruku.. 7 month achi inum compliant varala..
My area ground water tds near 3000tds& salty .so do we can use 50lph ro system ( we have need more water drink & bath)?
@r2_tech_tamil
4 жыл бұрын
If u want bath and external use.. u can fix water softener.. and please use RO for drinking only..
Bro membrane la vontron membrane okva bro?? ethu rate evlo bro....? Aprm inline la aqua spark nala brand ah bro? ethu evlo irukum? Please sollungaaaaa
@r2_tech_tamil
4 жыл бұрын
I don't know exact price.. Bcoz oruoru area Ku rate change agum.. TDs 500. Kula iruntha vontron is best.. Inline filters aqua spark OK thaan.
Bro,inner membranes how much cost bro???
Sediment ,sv,prekarbon,pump,memarine,mineral,uvlamp,etha farmation correct ah solluga na
@r2_tech_tamil
4 жыл бұрын
Video podren brother.. Soon..
How to find correct membrane for our RO unit please guide me 🙏🙏🙏
Brother, it is very very nice video. You have explained so well. Thank you very much. Only yesterday I removed all the parts of our filter as some dirt was stuck below the water tank. I cleaned that and fitted everything as it was. Had many doubts. You cleared it. Rambu Nanri. Enakke nalla Tamil varadu but understand to some extent. Sorry.
@JustBe1974
3 жыл бұрын
We have exactly this kind of filter. Lid of water storage tank is broken a bit. Where can we buy new one? 3 doubts: 1. why should we change RFO for waste water regularly ? 2. TDS of our water filter is 10, which us too less. How can I make increase it say make it 75? You can answer in Tamil. I have people to translate. I am also happy to hear in Tamil. 3. Where can we get filter Cover? It is good idea to have it.
Thanks for the video Sir... But why have you removed the bio filter and not inserted it again?
@r2_tech_tamil
4 жыл бұрын
Customer don't want this..
@PawanKumarYouTube
4 жыл бұрын
@@r2_tech_tamil okay... After watching your video, I got the hope of replacing my ro accessories myself. Am going to try today evening.. Thanks for the tips :)
🙏🙏👍🌹👍
Entha tds waterku eñña memberane use pantrathu nu solunga brother
நான் filter system assemble பண்ணிட்டு water line தப்பா கனக்சன் பன்னி machine run panni parthen that time product water will come like waste water flow range but reject water will not coming so that i off the machine and check and then I'm identified water connection is wrong afterwards im changing the water connection in a right way by your vedio guidelines after that reject water only coming product water is not coming then i will check stage by stage by your vedio guidelines then i confirm that there is no product water flow in post carbon filter and then I checked the membrane housing reject water only coming out and product water is not coming out from membrane this is the current issue im facing in our RO unit please guide me 🤚🤚🙏🙏please tholar
Sir your video is good. நான் மெம்பரன் change செய்து பார்த்தேன்.ஆனால் ஒரு water மட்டும் தான் வருகிறது. reject water வரவில்லை.என்ன காரணம் என்று தெரியவில்லை.பதில் கூறுங்கள்
@r2_tech_tamil
2 жыл бұрын
Fr connect paningala.?
Sir y you didn't replaced the bio mineral Catredge instead of Normal Catredge? Please tell me bio mineral Catredge is not that much effective ah?
@r2_tech_tamil
4 жыл бұрын
Bio mineral catrage one of the best.. But customer don't want this.. Bcoz high cost..
sir, kent RO machine-il UF inline filter-ku bathil post carbon filter use pannalama?
@srimanoj7847
3 жыл бұрын
Use pannalam but uf use pannuna inum konjam purity kedikum
@aadhir8461
3 жыл бұрын
@@srimanoj7847 thanks
Pump 100 g. membrane which is suitable tholar nennga சென்னை ya tholar
150 tds gud result .why r u change full kit?
Bro advanced ro ellam vandhueruku...which is best.??..epo neenga katna adhey ro dhan nanum use panitu eruken..epo fulla membrane filters elamm change pannan sollitanga...3500rs aagumnu soldranga...adhuku nan new ro vangidalamnu pakuren...pls konjam suggestions sollunga
@r2_tech_tamil
4 жыл бұрын
U can buy any brand. But one suggestion yentha brand.a irunthalum RO+UV+UF and TDs adjuster irukamathiri pathu purchase panunga.
@gayathria6674
4 жыл бұрын
@@r2_tech_tamil okk thnx bro
@nirmalputtu3450
4 жыл бұрын
Sis u can buy blue star brand no 1 service starting 6 litre capacity 10900 6 stages of purification very gud duration also fast moving
@gayathria6674
4 жыл бұрын
@@nirmalputtu3450 tq
Bro , purifier la yellla filter rum (carbon filter membrane ,etc.. )yeatha months Ku oru vatti mathuna nalladhu bro
@r2_tech_tamil
4 жыл бұрын
12 months or 6000 (per day 15 ltrs) liters product water..
@srideepamstudio3958
4 жыл бұрын
Thank you so much brooo ....
Hi unga videos super bro please email id sonna doubt kekka esiya erukkum odana answer therinjikka mudium please bro
total filter matha evl cost agum bro?
Bro yalaru oru thapu pandringa sediment and pre ah connect panumbodhu product label crt ah irrukura mari vaikanum.. aero mark paka kudadhu ..adhuku ethamari tube extend panikalam ..en idha solldrana suppos raw water air block vandhuchina pre carbon la stay aidum adha
@srimanoj7847
3 жыл бұрын
5year ra pannure endha problem um vandhathu illa bro.. no problem nenga epdy vanalum vikulam nenga sollura mathi vacha pakka nalla irukum
All filter change how much charge coming
Ithula uv filteration iruka.. Illana add pannika mudiyuma..!?
@r2_tech_tamil
4 жыл бұрын
UV illa.. Venuna add panikalam.
Why you shouldnot replaced the SV&PUMP INPUT tubes, your cabinet have more space inside you connecected the F/R INSIDE THE CABINET , OK
TDS aevlo erukkanum bro pls tell
How R O pump motor stop after tank fill sir I need ELECTRICAL drawing
Hi membrane la irundhu post carbon ku water Pola enna panradhu
Total kit price bro
I am having 100gpd booster pump...which is the suitable gpd membrane ....how much FR has to use...
@r2_tech_tamil
4 жыл бұрын
100gpd membrane available in market.. in India we are commonly used FR450. U can also use FR550
@LokeshKumar-iy5fd
4 жыл бұрын
@@r2_tech_tamil thank u for ur reply
@LokeshKumar-iy5fd
4 жыл бұрын
@@r2_tech_tamil can u share ur whatsapp no.
@LokeshKumar-iy5fd
4 жыл бұрын
@@r2_tech_tamilwhich smps suit for 100gpd booster pump
@LokeshKumar-iy5fd
4 жыл бұрын
@@r2_tech_tamilmy booster pump capacity volts- 24vdc and max. Current - 1.4a which s suitable smps to buy...pls guide me
Sir product water fills veery fast and reject water comes very slow, I have changed rf also, still it is in same condition. What is the reason and tell me the solution also. Thanks
@r2_tech_tamil
3 жыл бұрын
Membrane housing la product and reject tube wrong.ah connect panirukinga
@srinivasmurthy9302
3 жыл бұрын
Sir I have connect reject water pipe to right side and product water to bottom side
Bro nangalum entha type thn use panrom... Engaluku water rmba kamiya varuthu athuvum drop ah drop thn varuthu ana reject water rmba neraya pothu.. Ethanala epdi aguthu... Sollunga bro... Main filter change pannanum ah ila ful ah change pannanum ah bro
@r2_tech_tamil
4 жыл бұрын
Membrane change panramathiri irukalam, koodave inline filters.m change panikonga
@chitrachitra6090
4 жыл бұрын
Thank u sir.... Membrane matum change pannanum na evlo varum? aprm inline filters evlo varum.... Bro best company sollunga bro membrane ku ... Please reply me bro
@anandlakshmanan4078
3 жыл бұрын
@@chitrachitra6090 1500 to 2500
Buy online link sollunga bro
If we change all how long it will take to fill the tank ?
@r2_tech_tamil
3 жыл бұрын
if booster pump working good condition, its will fill 15 ltrs above per hour.
@srimanoj7847
3 жыл бұрын
input water pressure nalla irundha Pump and membrain 100 gpd irqundha 19or 20 litter per hour
@gmg81
2 жыл бұрын
Total cost. Repair
In memberain filter two outlets how to find product water and waste water?
@r2_tech_tamil
3 жыл бұрын
bottom LA center. a varathu product water and side LA varathu reject water.
Echan moter This all item change panuna evolo varum Bro
@r2_tech_tamil
4 жыл бұрын
Minimum 2.5k varum.. based on brand and water TDs.
Anna can you please give any links to buy spares for the motor and filters.
@hari8456
3 жыл бұрын
Bkn
@hari8456
3 жыл бұрын
9566094665
@hari8456
3 жыл бұрын
Which can ariya
Anna ro free kudupangala please Idhu kathukutta shop vechikkalama
Bro changed membrane and inline filters, first uh filter agi tank la oru 30% fill achu. Aparam stop agitu water varadhu. Ana motor run agudhu. Epdi bro fix panradhu
@r2_tech_tamil
4 жыл бұрын
Maybe pump pressure low.ah irukum.. Solenoid valve LA irunthu water out aguthanu check panunga..
@ireweohnp847
4 жыл бұрын
Solenoid valve lendhu out water varala bro, epdi fix panradhu solunga please
Bro burning smell from output water technician came and changed booster and uv light but no use still geting burning smell what will be the reason
@r2_tech_tamil
2 жыл бұрын
Membrane changing must.
@PravinKumar-xm9zr
2 жыл бұрын
Membrane and all filters was changed 6 months before
@v.gwaterworld566
Жыл бұрын
Check SV.
@PravinKumar-xm9zr
Жыл бұрын
@@v.gwaterworld566 have changed solenoid valve, pump also
1500 to 2000 tds ku , enna brand membrane, inline filter use pannalaam. Online la purchase panra maadhiri brand.
@r2_tech_tamil
4 жыл бұрын
Dow
@hari8456
3 жыл бұрын
Sir online 800 mela elukathu ple misty brand vankuga I am 10 experience I n filed 9566094665
Nanga membrane change panunom new va but work agala , water upto motor outlet varudu, reject water varudhu but product water la varala
@r2_tech_tamil
4 жыл бұрын
FR connect panitingala..?
@veeraganapathy790
4 жыл бұрын
S forgot it and then connected. Thank you for your information
For input 380ppm raw water the product water ppm is 75. Also salty and output is reduced. What i need to do..?
@r2_tech_tamil
4 жыл бұрын
May be membrane filter going to gone..
@r2_tech_tamil
4 жыл бұрын
Try to change membrane
What happen to mineral filter shown initially. Why can't that be added after post carbon?
@r2_tech_tamil
3 жыл бұрын
becoz we want minerals for product water.. if we add that catrage before membrane filter minerals also going to reject side..
@easwaran83
3 жыл бұрын
@@r2_tech_tamil initially before the water going to tank you showed mineral filter. But after assembly of new, you dint add that mineral filter which you removed.
@r2_tech_tamil
3 жыл бұрын
bcoz customer don't want to fix new mineral catrage
Only product water only receiving what is the issue.
Sir ithuku rate Change pannathuku
SiVAKUMAR RAYABURAMURAM
Please solution solunga
Almost Changed all the filters. How much cost for it?
@r2_tech_tamil
3 жыл бұрын
3000/-
Direct connection panina pure and out water rendum varudhu bro, ipo solenoid valve matum mathanuma
@r2_tech_tamil
4 жыл бұрын
S..
How many flow rectifier fixing in one unit
@kalaiyarasanthangarasu3843
10 ай бұрын
One
Water low varuthu ena pananu sir
பட்ஜெட்+நல்ல= எந்த.மெமரின் போகிறது.சார்.விளக்கம் கொடுங்கள் சார் ரொம்ப உபயோகமாக.இருக்கும்
Solenoid valve lendhu out water varala bro, epdi fix panradhu solunga please
@r2_tech_tamil
4 жыл бұрын
Solenoid remove panitu direct.a pipe.a pump LA kuduthu run pani parunga.. Out put water vantha solenoid change panunga..
@ireweohnp847
4 жыл бұрын
Direct connection panina pure and out water rendum varudhu bro, ipo solenoid valve matum mathanuma
I'M SRIMATHI RAMAN. LIVING IN SRIRANGAM,TRICHY.PL LET ME KNOW SERVICE PEOPLE HERE&ALSO PL GIVE ME COST OF INNER FILTERS
Product water oda tds minimum evalo ji irukalam?
@r2_tech_tamil
4 жыл бұрын
40ppm
bro tank full ayidichi anna waste water vanthukita irruku konjam explain pannunga
@r2_tech_tamil
Жыл бұрын
Solenoid vale problem. SV change panunga.
@ananthpadmanaban7358
Жыл бұрын
@@r2_tech_tamil thanks bro
Hi,Float seriya work aga matuthu,Ela time nanga manual floata close Pani open pana than pump work agutha. Ena reason?
@r2_tech_tamil
4 жыл бұрын
Ena brand..?
@reviewer5873
4 жыл бұрын
@@r2_tech_tamil dolphin
@reviewer5873
4 жыл бұрын
@@r2_tech_tamil tank la water level fulla kami ayuduchanua,switch on pana peragu work aga matuthu.Manual float fulla close panitu open pana start aguthu
@r2_tech_tamil
4 жыл бұрын
Flot switch remove panitu potu parunga. Work agati switch change panithan aganum
@reviewer5873
4 жыл бұрын
@@r2_tech_tamil ok thanks.
Bro water pump run aakuthu but water out vara maatithu apro membrane ku water poogala Ena pannannum oru service ku vanthu eruken bro
@r2_tech_tamil
4 жыл бұрын
Carbon filter or SV chock agiruku
@parthipanbpanb6771
2 жыл бұрын
Service theriameye service ku vanthurukiya pa enna koduma
மிஷின் மோட்டார் ஓடுது.. எல்லா சிலிண்டர்யும் check பண்ணியாச்சு.. மெம்ப்ரான்ல அவுட்டர் தண்ணீர் வந்தது.. குடிக்குற தண்ணீர் பில்டர் ஆகவில்லை.. மெம்ரான் கலட்டி சுடுதண்ணீரில் ஊரவிட்டதும்.. மெம்ப்ரான்ல இருந்து குடிக்குற தண்ணீர் வர ஆரமிச்சுடுச்சு... ஆனால்.. தண்ணீர் நல்ல தண்ணீர் கிடைக்கல.. ஏன்
Sir waste water non stop ah pogudhu enna complaint ah irukum
@r2_tech_tamil
4 жыл бұрын
Running time LA pogutha illa unit stop la irukumbothum water pogutha..?
@2GUDMEDIA
4 жыл бұрын
@@r2_tech_tamil unit running timela pofudhu
@r2_tech_tamil
4 жыл бұрын
Basic 1:3 1 liter product water Ku 3 liter waste water varum.. Athavida athigama vantha maybe membrane filter poirukalam.
படம் வரைந்து விளகினால் நல்லா சுலபமா இருக்கும். மெம்பெறனில் எது நல்ல தண்ணீர் வாள்வு எது வேஸ்ட் தண்ணீர் வாள்வு என்று சொல்லவில்லை. விளக்கம் பத்தாது.
@r2_tech_tamil
2 жыл бұрын
Watch my channel play list.. kzread.info/head/PLjrddpP2cI3ueMGA51ZyHNi6vKD64j9xM 29 videos available.
Neenga chennai ya tholar
@r2_tech_tamil
2 жыл бұрын
No trichy.. WhatsApp vanga.. 9894025260
@mohankasi3
2 жыл бұрын
@@r2_tech_tamil ok tholar
Filter rate solunga.....? Filter angu kidaikkum
@srimanoj7847
3 жыл бұрын
Ellame sollita ro technician ku work illama pooirum nengale ellame pannuremathri irundha itha nambi work pannurevanaga sapdorathuku enna pannuvanga avungalum konjam valatom 🙏 itha pathi just tharunjikonga
What is gbd?
@r2_tech_tamil
3 жыл бұрын
Gallons per day.
Where I get ro booster pump in chennai good price
@r2_tech_tamil
3 жыл бұрын
I don't know sir, i am in trichy
FR usage yana bro,solunga
@r2_tech_tamil
4 жыл бұрын
It's flow restrictor.. Means speed break..
@hari8456
3 жыл бұрын
Flow rejected
Hi