How to replace the AC units leaking condenser coil?
How to braze copper? Video
• How to braze copper? @...
How to find a refrigerant leak? Video
• How to find a refriger...
How to use a Vacuum Pump? Video
• How to use a Vacuum Pu...
HVAC Tools I use
Nitrogen Flow Meter
amzn.to/3SscTl0
Nitrogen Regulator
amzn.to/3LHLUQg
Thermadyne TurboTorch
amzn.to/3Sx8spb
Uniweld KC100P Centurion Weld, Braze Outfit
amzn.to/3Sx8spb
Diversitech 800-002 Pro-2000 Leak Detector Spray
amzn.to/3C8Kkni
Join this channel to get access to perks:
/ @taddydigest
Wanna learn more about hvac? Check out my hvac tips for technicians playlist.
• HVAC Tips for Technicians
Taddy Digest Website
taddydigest.com/
Click this link to get your website consultation.
moderncontractorwebsites.com/...
Modern Web Studios has Built, hosted and maintained my Website.
modernwebstudios.com/
Fill out the contact form at modern web studios
modernwebstudios.com/contact/
Пікірлер: 56
Another job well done. Just goes to show how important it is to service these unit on time .keep the videos coming
Mr Teedd you forgot to wash the control board too 🤣🤣
@TaddyDigest
2 ай бұрын
lol 😆 😂
Excellent videos like always good info thank you
Great video looks like those older York units were better than the new ones built now I mean 11 years on coil replacement and only cause lack of maintenance not bad. Great job bro.
Thanks for going through the install step by step. Good work.
@TaddyDigest
2 ай бұрын
No problem 👍
Always a good video. Guess having the micron gauge as far away from the pump isn't something you did this time.
Great video and vey helpful. Just one question- I was taught to have vacuum gauge as far away from the vacuum pump as possible but you seem to have it very close to the pump. Keep up the good work and will look forward to your next video.
Knowledgeable video
@TaddyDigest
2 ай бұрын
Thank you 😊
Good stuff Tad‼️ Precise, Quality job🎯
@TaddyDigest
2 ай бұрын
Thank You Brother
@manvirbrar190
2 ай бұрын
@@TaddyDigest hi when you braze what’s pressure you set on oxy and map gas..
Great job !
Job done correctly.....👍👍
I use a leaf blow to clean the leaves out it works great
When I rarely use manifold gages I bleed across the manifold also.
nice work.
Good job tadd
@TaddyDigest
2 ай бұрын
Thanks for watching
You are awesome man thanks
@TaddyDigest
Ай бұрын
You are!
I was wondering why you didnt have the tiny mirror after each braze 😅 excellent video brotha
@TaddyDigest
27 күн бұрын
Next time Brother hahaha
The flow regulator reads in cubic feet (per minute/hour) That is what the regulator indicates - not PSI. Your particular device has a max flow rate of 75 SCFH
😅👌good job.
Heat puddy not needed when brazing filter drier?
Mr Teedd How these are very different from those in India ?
I did that with my friend we had problem after we put the Freon the cages was going in Negative whats the issue you think and thanks
Awesome video do you like analog gauge better than digital gauge
Suction pressure should be 40°
23 on the SH seems a bit high correct? thanks for sharing
@TaddyDigest
Ай бұрын
yes absolutely
#GIVEAWAY Very detailed and organized, Love it! Thanks Tad
@TaddyDigest
2 ай бұрын
Entered!
you call a professional...😮
is R-22 still legal in US ? R-32 is zero Ozone Depleting alternative
Tech tip I always use the nitrogen to clean the control panel 😀
@TaddyDigest
2 ай бұрын
That's a good idea!
👍
Taddy it's not a good practice having vacuum gauge right next to the pump.
What tip
4000kpa or 580-600psi i pressure test to.
@TaddyDigest
2 ай бұрын
very nice
Noticed the high pressure sensor was chopped
This unit used a piston as a TXV?
@TaddyDigest
2 ай бұрын
yes sir
I don’t like when technicians do the installs without using raising blocks To protect the bottom of the units
taddy why filling the system by nitrogen otherwise you can used Air
@TaddyDigest
Ай бұрын
nitrogen is an inert gas
@user-uk7qu2et9o
Ай бұрын
@@TaddyDigest if i used air to check the leak it is ok
Its a yerk unit they always leak unfortunately all brands going with micro channel
Never put your vacuum gauge on on the pump!!
You made a mistake. You should always put the vacuum gage on the opposite side when pulling a vacuum, it give you a more accurate measure whether you pulling the required amount of vacuum, or not. You do not not connect your gage at the vacuum pump where you have the lowest vacuum, instead you put the vacuum gage on the High-side, so when you read 500micron, you know you have a deep vacuum all the way through the system. Also, you should go bellow 500, like >300, and make sure it don't pull above 500micron in 10 minutes. And use a dedicated vacuum hose, rather than the one you used for refrigerant charging. God(Jesus Christ) Bless! :)
@TaddyDigest
22 күн бұрын
Thank you, brother, I really appreciate your advice