How to Properly Reinforce Steel Deck Flooring System - Tagalog Tutorial

This video explains about how to provide an extra reinforcement using steel deck flooring system.

Пікірлер: 154

  • @johnneil1313
    @johnneil13134 ай бұрын

    Suggest ko dapat provided kayo ng calculation din engr. Para mas okay. Yung sinasbai niyo na positioning ng rebar nacoconsider yung sa calculation so yung effective depth mo magvavary ngayon kung san mo ilalagay yung rebar mo then icheck mo bending moment mo kung ok then saka mo macocompute shear studs size and spacing mo.

  • @ethanieldee8540
    @ethanieldee85402 жыл бұрын

    Engr. You deserve more than 5 digits subscribers. Andami kong pinapanood sa youtube to gather information sa mga gusto kong matotonan. Tapos hnd pwedeng hindi ko mapanood ang video mo to validate all those na nalamang ko dito sa youtube. Iba talaga pag mag theory na kalakip sa discussion and napakagaling pa mag explain.

  • @ethanieldee8540

    @ethanieldee8540

    2 жыл бұрын

    Naging professor po sana kita during my undergrad.

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Thanks

  • @relardztv605
    @relardztv6054 ай бұрын

    Very nice job super effective and informative video thanks you for sharing useful video dahil sa vlog tutorial MO Maraming knowledge ang nakukuwa ko mula sa inyo. About steel deck

  • @johnwick-mb3pk
    @johnwick-mb3pk3 жыл бұрын

    thank you po sir...i salute you..malaking pakinabang ang inyo pong kaalaman pra sa matibay at safety ng structura...God bless po..more power...

  • @rrrx689
    @rrrx6893 жыл бұрын

    The best one.Well explained at napakalinas .Keep it up sir .More videos on design 🙏🙏🙏

  • @reynaldosira5770
    @reynaldosira57702 жыл бұрын

    Another free learning on KZread. Thanks for sharing. Sir.I'm your KZread follower.

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Thanks

  • @harronadjok9036
    @harronadjok90363 жыл бұрын

    always learning a lot. tnx sir👌👌

  • @nardopespes9209
    @nardopespes92092 жыл бұрын

    Thank you sir sa kaalaman .

  • @watchtvecs8037
    @watchtvecs80372 жыл бұрын

    Thanks Po sa info....I'm always watching your videos....I hope maybe I can get some files for the design

  • @edwinvicente7152
    @edwinvicente71523 жыл бұрын

    sir,the way you explain the floor system,cgurado ako isa kang structural engr.

  • @edwinvicente7152
    @edwinvicente71523 жыл бұрын

    thank you sir,stud pala ang kailangan para ma avoid ang pag skid,malaking maitulong ng stud lalo na sa transverse direction dahil walang bottom bars dyan.

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Tama po, check lang natin kung hindi mabubutas kasi may mga Steeldeck na manipis ang gauge, pag nabutas huwag natin ituloy ilagay nyo nalang yung bars along bottom of flute kahit every other flute para hindi madyado magastos, use 10mm, hook and tie at one end (far-most side of beam). Also important din yung extra bars at every top of support yung sinabi ko sa video na extended at L/4 each side of interior beams. Thanks

  • @michaelmelocoton8197
    @michaelmelocoton81972 жыл бұрын

    Salamat sir..

  • @marvintapar6063
    @marvintapar60633 жыл бұрын

    Please more vid pa po😁

  • @MA-dz9qt
    @MA-dz9qt2 жыл бұрын

    Thank you sir. Deserve 100k subs

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Salamat po

  • @vergelredcanaveral

    @vergelredcanaveral

    2 жыл бұрын

    Agree!

  • @johnchristopher8187
    @johnchristopher81873 жыл бұрын

    Thank you sir:)

  • @rudyfernando916
    @rudyfernando9163 жыл бұрын

    Nice video Engr, thanks for the valuable information. Agree ako sa suggestion to add more steel, it is not a waste of money pero added strength sa flooring. I have seen similar construction (sa middle east) at 2 rebars pa nilagay. Hindi ko alam kung tama ba na lagyan ng 1 inch spacer (between rebars to metal decking) para magkaroon ng concrere cover ang mga rebars. Well done, keep up the good work and God bless.

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Thanks

  • @materesavillanueva

    @materesavillanueva

    3 жыл бұрын

    Rudy Fernando personally, i think spacer is required for the reason na binaggit po ninyo..

  • @jaycrisgenota4484
    @jaycrisgenota4484Ай бұрын

    Thank you po ^^

  • @reubensuperales3105
    @reubensuperales31053 жыл бұрын

    dahil dito subscribe ako sayo engr

  • @franciscojrlarita441
    @franciscojrlarita441 Жыл бұрын

    Sir salamat sa info sa tamang reinforcement ng steel deck. Pero para sa akin, isabay buhos ko yung beam at slab para monolithic at para din sa tamang sukat ng effective depth ng beam ayon sa theory.

  • @JamesEmmanuelleGalvan-qf1rg
    @JamesEmmanuelleGalvan-qf1rg5 ай бұрын

    Engineer may video po kayo about sa analysis/design ng slab on steel deck?

  • @rodels.3745
    @rodels.37453 жыл бұрын

    Maganda yang sharing nyo sir at jnterested ako pero sana meron actual demo sa construction site kasi nahirapan ako sumunod sa ibig nyo mangyari lalo na at mahina ang sound

  • @boy-br2tr
    @boy-br2tr3 жыл бұрын

    Additional info po, yong grove ng steeldek dapat along short span ng slab para mas matibay. Also, pag lampas na po 4.5mtrs yong length ng slab/steeldeck, recommend po lagyan ng lintel beam along long span to allow or avoid sagging ng slab/steeldeck. Thanks po sana makatulong dagdag kaalaman.

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Thanks sir

  • @vrenanonical9108

    @vrenanonical9108

    2 жыл бұрын

    hello po pwede po malaman kung san niyo po nabasa or nalaman yung recommendation nayan? for academic purposes lang po, salamat sir

  • @fidelgolla7539

    @fidelgolla7539

    2 жыл бұрын

    Ang direction po ng steel deck kung bakit along the shorter dimension is because steel decking follows the principle of one way slab where main bars are placed along the shorter direction

  • @franciscojrlarita441

    @franciscojrlarita441

    Жыл бұрын

    @@fidelgolla7539 tama, kapag nasa shorter span yung main bar ay ang strength nito ay maganda na makapaghold ng other bars.

  • @ricaesteban6913
    @ricaesteban69133 жыл бұрын

    Good day po Engr. pag steel decking po ba di na inaapply or sinusunod yung one way slab or two way slab rule?

  • @reymondcabanlig2774
    @reymondcabanlig2774 Жыл бұрын

    Sir, sa makatuwid po unnecessary yung nilalagay nila na rebar mat (usually spaced 200mm both ways) na nakapatong sa steel deck at ang importante lang po pala is yung sa top bar na nasa beam location extending perpendicular to the beam, and may I know po sir saan po dapat ito naka hook?

  • @bienramos7587
    @bienramos75872 жыл бұрын

    Suggestions lang sir..mas maigi gamitin yung stud na weldable..ang rebar na ginagamit sa site are not recommended to weld (ASTM 615) ang weldable po ay ang ASTM706..

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Agree thanks

  • @arkinimation6394
    @arkinimation63942 жыл бұрын

    Shear studs should be welded to the flange of a steel beam. Hindi puede weld to the deck, Di ba?

  • @rangom812
    @rangom8123 жыл бұрын

    Thank you sir very informative..civil eng grad din po ako sir.... Ask ko lang sir sa layout ng rebars sa steel decking sir need pa ba mag hook ako sa dulo ng rebars...Thanks sa reply sir...

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Yes I suggest to hook at least 50mm and reach the farthest side of the beam. Thanks

  • @nirdla0822
    @nirdla08223 жыл бұрын

    Sir di na po economical kung dagdag p ng reinft?

  • @paul71ml
    @paul71ml4 ай бұрын

    Paano po ang proper installation ng steel deck kung built up steel beam ang support?

  • @jr-vb3zo
    @jr-vb3zo3 жыл бұрын

    Sir may design tutorial or marrecommend b kayo design software para sa flooring na may metal deck. Thanks

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Check po ninyo sa mga brochures ng steeldeck meron sila ready-made na table model and design gauge for a given spacing and loads. You dont need to design. Yan advise po natin sa video is to guide those who are using it improperly but if anyone who will follow the brochures from the supplier you dont have to provide those bars that I mentioned in the video. Also advisable lang po yan sa mga span more than 3meters. Thanks

  • @ethanieldee8540

    @ethanieldee8540

    2 жыл бұрын

    @@jsdesign_engineeringtv3633 Engr. Sana po nabanggit nyo to sa video nuh. I thought applicable sa lahat ng span. Namention rin lang naman ang mga L/3 to L/8, sa RCC din po ba di na inaapplu ang L/3 to L/8 pag less than 2m span ng beam?

  • @gerrymillare8516
    @gerrymillare85167 ай бұрын

    Dapat ang bilhin na steel deck ay yong may mga depressions pra may shear keys. Yong profiled plain steel ay pang-bubong lng without concrete. Sobrang nipis ng steel deck kya hindi advisable n magweld ng shear rods at tsaka may calculation yon pra malaman ang spacing (depende rin s shear capacity ng joint between steel deck and shear rod which I think very small considering the thickness of the steel deck).

  • @filecategory6596
    @filecategory65962 жыл бұрын

    Hello sir. Required bang mag lagay ng EXTRA BARS sa Discont. na beam? Ang naintindihan ko po kasi is sa support lang required mag extra bars 1/4 or 1/3. Hoping masagot nyo po. Salamat sir. Been a subscriber since last year. More power

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    May mga designer hindi naglalagay sa discontinuous-end, but ako nag lalagay, L/5 space at 300 same size sa intermediate support. Thanks

  • @aeronsycezar
    @aeronsycezar2 жыл бұрын

    paano po ba ang tamang pag install ng steeldeck sa connection ng beam?

  • @maveilgrutas246
    @maveilgrutas2463 жыл бұрын

    Sir ask ko lang po ano po sa dalawa ang mas maganda ang web deck or wave deck para s. Bahay.salamat po.

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Ang ma ipapayo ko po, bilhin ninyo yung kung saan kayo makakatipid. Ang importante dyan kumausap kayo ng installer who has long years of experience in installing steel decks, dapat alam nila kung paano ilalagay yung mga extra bars na hindi masyadong marami pero nasa tamang location

  • @virgilioagsalda3365
    @virgilioagsalda33652 жыл бұрын

    Thanks Sir sa info. Tanong lang Engr paano ba ang computation ng ibabayad Ko sa contractor na maglalagay ng steeldeck at magbubuhos sa akin ang steel deck at concerto. Salamat po

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Practical computation nyan, dapat alam nyo kung ilan ang tao na gagawa, how many days gagawin especially yung steeldeck installation. Then times rate per day. Roughly mag karoon kayo ng idea, syempre yung rate ng tao varies depende sa skill, at kalakaran sa lugar ninyo. Thanks

  • @gnidnoeled786
    @gnidnoeled7864 ай бұрын

    Sir ang bottom bar na tinali sa studs nakadikit po ba sa steel deck o may clear concrete cover dapat?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    4 ай бұрын

    Mas maganda kung may 20mm gap from steeldeck

  • @oliverumerez5531
    @oliverumerez55313 жыл бұрын

    engener ung bkal na ni welding patayo every 4feet at ung ilalagay na bakal sa baba welding din ba o pwede ng itali ng tirewire

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Hindi na po need yung bakal sa baba kung meron ng bar na patayo, enough na yan para kumapit yung steeldeck sa concrete (option 1 and 2 yan), but yung extra bar sa top support kailangan talaga. Make sure lang po na applyan nyo ng epoxy primer yung mga welding "spots" pati dun sa ilalim ng deck para hindi mag simula ang rust. Salamat

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Kung napili nyo naman yung bakal sa baba, itali lang ng tie wire no need to weld, kahit every other flute para hindi masyado magastos, 10mm lang yung size. Advisable po yan for a span of 3meters or more. Kung may question pa tanong lang po kayo. Salamat

  • @pedingdurante9524
    @pedingdurante95242 жыл бұрын

    meron ho ba kayong mga ready designed worksheet na ibinibenta as books references

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Videos lang meron ako sir. Thanks

  • @misharyrashid1142
    @misharyrashid1142 Жыл бұрын

    Sir baka pwedi idagdag mo yung size ng bar.

  • @ivanjoshuaobis2399
    @ivanjoshuaobis23992 жыл бұрын

    Goodpm sir, ask ko lng po kung anu mas matibay, dapatvpo ba ang rsb ng slab ay umilalim ng rsb ng beam or dapat sa taas ito nakapatong. Thanks po

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Monolithic pouring naman I suggest sa ilalim ng beam top bars yung slab rebars. Thanks

  • @alexpoon62
    @alexpoon622 жыл бұрын

    Engr. Kung yung span ng steelfecking is 3 meters or less. Ideally pa rin ba maglagay nung additional rebar sa ilalim?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Sa tingin ko midspan pwede hindi na for 3m or less, but top bar at support mag provide kayo at least 30cm o.c. spacing

  • @playtickle56
    @playtickle563 жыл бұрын

    gud day po engr. tanong kulang, ano ho ba ang ideal bar spacing pag steel deck at gaano ho ba kakapal ang buhos?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Minimum of 1 bar every deck flute, thickness minimum of 4 inches.

  • @playtickle56

    @playtickle56

    3 жыл бұрын

    @@jsdesign_engineeringtv3633 salamat po sa reply engr.

  • @jenniferpatagoc5859
    @jenniferpatagoc58593 жыл бұрын

    Hello po..ask lang po..Ilang days po ba ang aantayin para makuha na ang staging pagkatapos ang buhos ng slab sa steel deck?salamat po

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Parehas din po ng conventional concrete slab, after 1week pwede na mag bawas ng support mga 50percent, iwasan lang natin mag lagay ng stockpile especially sa midspan for at least 3weeks

  • @exequielmorales7865
    @exequielmorales78652 жыл бұрын

    Sir good pm , diba Yung steeldeck yan Yung pamalit ng crank bars? Napansin ko po nag lagay kayo Ng shear studs..ang alam ko ang shear studs ay Gina gamit Kung steel beam Yung gamit, dahil doon cya e welding, correct me if I'm wrong.. Tapos Yung sa rib nag lagay kayo ng reinforcement, diba applicable lang Yun sa two way slab? Thanks..

  • @kennydelgado9900

    @kennydelgado9900

    3 ай бұрын

    ganto din yung idea na naiisp ko ang shear studs ai for Steel Beam hindi mismo sa steel deck

  • @nepbulls1617
    @nepbulls16173 жыл бұрын

    What's the purpose of the corrugations, ribs and indentations on the steel deck? Do they not prevent slippage or disattachment of concrete from the surface of the steel deck?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Yes, that is absolutely the purpose of it. However, there are no clear consensus about the effectivity of such features especially on generic or unbranded products. As a designer we always treat every condition in a worst -case scenario, and my video explains it in general about "how to properly reinforce" in case those things happen. FYI

  • @chocolord1996
    @chocolord1996 Жыл бұрын

    okay lang po ba Engr. na magbutas sa existing composite slab to accommodate sanitary pipes po?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    Жыл бұрын

    Yes, but carefull on locations especially where bending is maximum. However, it is better if you anticipate hole locations before pouring in order to provide adequate dowels around it. Thanks

  • @chocolord1996

    @chocolord1996

    Жыл бұрын

    @@jsdesign_engineeringtv3633 maraming salamat po

  • @cindyfrancisco9734
    @cindyfrancisco97342 жыл бұрын

    Engr pwede bang butasan ang steel deck? For ceiling dowels

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Wala akong makitang problem dyan, pwede naman

  • @jorellculala3061
    @jorellculala30612 жыл бұрын

    sir pag lumundo po ba ung steel decking may chance pa po ba ma flat sa ilalim or maging ok ndi po ito guguho pag lumundo

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    In my experience pag residential type ang loadings wala pa ako nakita nag collapse. Thanks

  • @julietvillagracia5281
    @julietvillagracia52813 жыл бұрын

    Accordingly, dapat d nakalapat bakal sa steel deck to avoid corrosion, pero d ba nagiispat din Ng bakal sa kanila?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Maliit naman ang chances ng corrosion especially kung interior slab (not directly expose to weather). Kasi ganun din naman gingawa ng marami sa regular rebar / meshwire they place directly on top the steeldeck flute( naka dikit din). But pwede rin naman maglagay ng concrete spacer to avoid physical contact. Sa welding spots, normally we apply epoxy primer only on weld points. Thanks

  • @nasserhapas4419
    @nasserhapas44193 жыл бұрын

    Boss Sound system problem at d ma linaw ang sinusulat mo

  • @reiden4442
    @reiden44423 жыл бұрын

    Ok po yung extra bar sa bottom. Kaso po sa electrical dun sila kadalasan nag lalagay junction box so i bend nalang yung extra bars? Thanks po.

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    I suggest skip mo nalang ang bakal sa lahat ng may electrical conduit para hindi congested walang kaso yan mas importante kasi yung extra top bar sa support

  • @reiden4442

    @reiden4442

    3 жыл бұрын

    @@jsdesign_engineeringtv3633 ok po engineer. salamat

  • @hontellaggo2570
    @hontellaggo25703 жыл бұрын

    Base on on some, they use steel deck, yet they use 2 way rebar is it ok?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    As far as I know steeldeck are normally treat as one-way slab because of its corrugation, I cant figureout how some are treating it as two-way, except they dont know how to use it properly

  • @elmopakeo-an4590

    @elmopakeo-an4590

    3 ай бұрын

    @@jsdesign_engineeringtv3633 in that case, they used perforated steel deck.

  • @joselitocancino3758
    @joselitocancino37583 жыл бұрын

    Boss ttanung lng po ung bakal k 12mm nilagay k pero 30x30 ang ginamit k mtibay din po b un boss?pero khit paano naglagay ako ng kaunting extra bar nya po boss

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Kung steeldeck, hindi kailangang maging both ways ang bakal, normally one way lang ang application nyan.

  • @joselitocancino3758

    @joselitocancino3758

    3 жыл бұрын

    @@jsdesign_engineeringtv3633 ganun po b.pero matibay po b?wla kc ako alm jn boss hehe

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Matibay po yan

  • @joselitocancino3758

    @joselitocancino3758

    3 жыл бұрын

    @@jsdesign_engineeringtv3633 slamat po engr..ngaun panatag n loob k ..

  • @pong3753
    @pong37533 жыл бұрын

    Hindi po ba may tulong yung steeldeck sa tension? Kc pag naglagay tayo ng additional steel bar sa bottom kawawa naman yung electrician jan paano nya ilalagay yung junction box at mga pvc pipe nya.. hindi po ba sir kaya po tayo mah steeldeck para makatipid sa bakal kc yung steeldeck din dagdag strength sa may tension? Tanong ko lng sir salamat..

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Correct po, dual function ang steeldeck kaya naging popular sa floor construction, but ang sinasabi po natin sa video kung masisiguro natin yung adhesion between concrete and steeldeck walang problema, kaya isa sa mga paraan nag lalagay tayo ng shear studs like we mentioned in our video. But pwede rin nama every other flute ang dowels para may room for utilities. Salamat po sa comment

  • @MyBootPrints
    @MyBootPrints3 жыл бұрын

    Sir pag naclip na po ba piece by piece yung steel deck, hindi na kelangan iweld?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Normally tack weld or spot weld lang po, then pour na ng concrete slab. Thanks

  • @MyBootPrints

    @MyBootPrints

    3 жыл бұрын

    @@jsdesign_engineeringtv3633 pwede po bang ipatong lang at hindi na iweld? thank you!

  • @jr-vb3zo
    @jr-vb3zo2 жыл бұрын

    Anong thickness po ng concrete from malalim n part ng steel deck. Thanks

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Minimum 100mm from top of flute, so it depends on deck profile, ex. If flute depth is 20mm total depth will be 120mm. I hope that answers your question. Thanks

  • @judeacob9949
    @judeacob99492 жыл бұрын

    Question: Engr, puro 1way reinf. ba talaga pag may decking, if not po, kailan gumagamit ng 2way reinf. ?? Pls reply po, more power and wish you good health sir with your family

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Yes, it should always treat it as one-way because of its flute. Thanks

  • @judeacob9949

    @judeacob9949

    2 жыл бұрын

    @@jsdesign_engineeringtv3633 salamat den sir~ nag subscribe na pala ako sa channel mo, nice content po, more blessing po ulet Papanuorin ko ulet ibang video niyo po, Hope you'll answer some of my questions next time (maraming thank you)

  • @gabgilgabgid3599
    @gabgilgabgid35993 жыл бұрын

    Engr, paano po ilagay ang electrical junction box kapag mag lagay ng additional bar sa gitna ng corrugated steel deck?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    I suggest skip nyo na yung extra bar sa portion ng electrical junction box, that's fine

  • @Aklantvchannel

    @Aklantvchannel

    2 жыл бұрын

    kalimitan expose na yon electrical, water line or yon tinatawag na mefps pagka steeldeck ang ginagamit. sa ilalim lang ng slab naka hanger.

  • @Aklantvchannel

    @Aklantvchannel

    2 жыл бұрын

    pagka bahay lang naman pwde siya iabang at butasin na lang. yon usual nag pag install ng mga junction box na hindi pa uso ang steeldeck. naka abang lang sa porma ng floor.

  • @gillianmilana7087
    @gillianmilana70873 жыл бұрын

    Ano po ba mangyayari sir kung pinilit gamitin steel decking sa two way? Salamat po

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Masasayang lang yung rebars mo sa other direction. Steeldeck is designed for oneway slab application

  • @johannafuentebella-alpas3682
    @johannafuentebella-alpas3682 Жыл бұрын

    Sir anong magandang gawin pag kapos ang steel deck.

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    Жыл бұрын

    One practical option, is provide intermediate beam then cast conventional rc slab. Thanks

  • @allyce06
    @allyce062 жыл бұрын

    Dikit po ba sa steeldeck floor Yung bakal na nilagay nyo sa baba?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Wala naman issue kahit naka dikit kasi permanent structure ang steeldeck, ok din naman kung lagyan ng spacer but not more than 25mm. Thanks

  • @jkm5015
    @jkm5015 Жыл бұрын

    Paano po yung extra bar sir sa ilalim sir hindi ko siya ma visualise salamat sir

  • @paulgenebautista7242
    @paulgenebautista72422 ай бұрын

    Haging pumaling drawing mo ser

  • @mrroy2187
    @mrroy21872 жыл бұрын

    Hi sir sabi ng iba mainit daw yung steel deck,paano ma reduce ang init?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Heat transfer cannot be prevented whatever material we use especially in tropical countries like Philippines. The solution is to place an insulation underneath if it really needed. Thanks

  • @mrroy2187

    @mrroy2187

    2 жыл бұрын

    @@jsdesign_engineeringtv3633 dba pwde sa ibabaw ng steel deck ilagay ang heat insulation bago buhusan sir?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    @@mrroy2187 Meron gumagawa sa ibabaw but it would be very expensive and I doubt few contractors know how to do it, its a special technology. I suggest, mag lagay ka nalang ng ceiling with enough room between ceiling and steeldeck para may air-circulation. Then kung gusto mo mag lagay ka pa din ng insulation sa ibabaw ng ceiling I'm sure it will make a difference. thanks

  • @mrroy2187

    @mrroy2187

    2 жыл бұрын

    @@jsdesign_engineeringtv3633 thank you sir

  • @clifordlanojan953
    @clifordlanojan9532 жыл бұрын

    Sir pwde po bah e patung ang steel deck sa concrete beam, hindi po i- beam ?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Pwede, marami gumagawa nyan. Monolithic din yung buhos ng deck slab sa concrete beam. Thanks

  • @clifordlanojan953

    @clifordlanojan953

    2 жыл бұрын

    Pero sir yung tapos na nabuhosan lahat o buong beam bali ,pinatong nalang yong steel deck after pwede po ba yon? Parang kahoy pinatong nalang sa, isang dahoy na beam, pwede ba yon sa steel deck?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    @@clifordlanojan953 Still possible, just roughen top surface no need to expose rebar, then place your decking on top existing beam (at least 2" sitting). I suggest provide stud(16mm dowel) drilled @ 600mm apart epoxied for proper adhesion between old and new concrete. I hope that helps. Thanks

  • @clifordlanojan953

    @clifordlanojan953

    2 жыл бұрын

    Thanks engr. Salamats talaga, kahit 2 am na sinagot mo parin ako, another kaalaman po sir, 🙏🙏🙏 still watching sa mga videos mo Sir, mas maganda ang pagka explain mo, maraming salamats po ❤

  • @clifordlanojan953

    @clifordlanojan953

    2 жыл бұрын

    Halo engr. Hopefully ma sagot nyo ako ulit, for rebar mattingbsa steel deck, pwede po bah, 0.30m sa ilalim 12mm dia. x 0.15 mm dia. sa itaas ? Matibay po bah to?

  • @rapskidooo
    @rapskidooo3 жыл бұрын

    Kailangan po ba i weld ang transverse bars?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Hindi po need ang welding sa straight bars. Thanks

  • @rapskidooo

    @rapskidooo

    3 жыл бұрын

    @@jsdesign_engineeringtv3633 ok lang po ba design na: bottom bars, 10 mm per pan. Top bars, 10 mm 300mm oc transverse bars. 12mm 900mm oc, 225 mm oc on L/4 along the deck span

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    @@rapskidooo saan mo gagamitin yung 900mm OC? Yung 225mm oc na top bars ok lang

  • @rapskidooo

    @rapskidooo

    3 жыл бұрын

    @@jsdesign_engineeringtv3633 bali yung 225mm top bars eh yun yung extra bar na nasa L/4. tapos yung 900mm oc yung continuous na bar

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    I suggest at least 300mm oc 10mm dia

  • @joselitobasa3661
    @joselitobasa3661 Жыл бұрын

    Mahina po audio mo engr.

  • @realprojecttools3543
    @realprojecttools3543 Жыл бұрын

    bad audio!

  • @leenjames470
    @leenjames4702 жыл бұрын

    Ang hina ng boses nyo, sir

  • @vicentecaro7008
    @vicentecaro70083 жыл бұрын

    No sound.

  • @tatsuikiml938
    @tatsuikiml938 Жыл бұрын

    Napakahina ng audio

  • @markkuleto1150
    @markkuleto11503 жыл бұрын

    Ang hina po ng audio

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Sorry sir, I'll try to improve my audio next time. Thanks

  • @dennismendoza4208
    @dennismendoza42082 жыл бұрын

    Sir partial pouring of beam po b Ang practice nyo not monolithic?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Most of the time monolithic

  • @joselitocancino1922
    @joselitocancino19222 жыл бұрын

    Engr tanung lng po ano kapal ng buhos ng metaldeck po?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Depende sa profile ng metaldeck, but normally 75mm excluding flute. If flute is shallow, say less than 20mm use 100mm concrete thickness. Thanks

  • @karlpayao5160
    @karlpayao51603 жыл бұрын

    Ganito rin po ba ang pag latag ng bakal pag two-way slab sir?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    3 жыл бұрын

    Ang steeldeck po advisable lang sa oneway slab because of those corrugations. Thanks

  • @ethanieldee8540

    @ethanieldee8540

    2 жыл бұрын

    @@jsdesign_engineeringtv3633 so kung two way slab ang mas maraming slab sa building. Better po ba na wag na mag steel deck?

  • @jsdesign_engineeringtv3633

    @jsdesign_engineeringtv3633

    2 жыл бұрын

    Yes you are right. Thanks

  • @reymondcabanlig2774

    @reymondcabanlig2774

    Жыл бұрын

    Sir, bigla lang po ako naguluhan.. So, kapag based sa dimension ng slab is two-way slab po, hindi po ba pwede gamitin ang steel deck? Sana po masagot niyo ang gumugulo sa isip ko po kasi lahat ng nakikita ko nagco-construct is naka steel deck lahat kahit two-way.