How to properly bleed air out on primary manifold for high efficiency Navien boiler.

Ойын-сауық

Пікірлер: 31

  • @frankdivincenzo707
    @frankdivincenzo7074 ай бұрын

    Thank you TJ. You just save me a service call.

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    4 ай бұрын

    Glad to help

  • @ChuckKarl525
    @ChuckKarl5255 ай бұрын

    Fantastic! this is what I was looking for.

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    5 ай бұрын

    Glad I could help!

  • @frankdivincenzo707
    @frankdivincenzo7074 ай бұрын

    Thanks!

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    4 ай бұрын

    No problem!

  • @ctmale1956
    @ctmale19563 ай бұрын

    great......

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    2 ай бұрын

    Thank you ☺️

  • @mehranhassanzadeh4871
    @mehranhassanzadeh4871 Жыл бұрын

    Thanks TJ that was very helpful. Can you post a video how to change the 3-way valve on Navien NCB-240 H please? there are some video on the older models not the models. That would be very great. Cheers

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    Жыл бұрын

    I did not have a service call yet for changing that model for 3 way valve. Once I have one I will make a video.

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    7 ай бұрын

    I just have the video uploaded for 3 way valve

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    7 ай бұрын

    kzread.info/dash/bejne/rH6Ys8uaodyyhc4.html that's the video

  • @derekjackson6084
    @derekjackson60847 ай бұрын

    Hey are you familiar with circulator pumps? I am putting a new one in and i have the part but only one shut off valve. From what I see on YT if you only have 1 shutoff valve you need to "bleed it" I guess of the air. Are you familiar with that? I have pictures as well.

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    7 ай бұрын

    You will need to drain water in that zone and yes bleed air out when done to circulate the water.

  • @amadogonzalez6815
    @amadogonzalez681510 ай бұрын

    If you need to make a repair to the piping in one of the zones being serviced by the boiler, how would you bleed the system after the repair?

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    10 ай бұрын

    Every zone have it's on isolation valve and bleeder boiler drain. You just isolate that zone by shutting off the return valve and open boiler drain with hose to the bracket, once you feel the hot water and no more air bubbles then you can turn the drain off and turn isolation valve back to on.

  • @jonhopkins2648
    @jonhopkins26486 ай бұрын

    I will definitely try this as well i have run hot water faucet for several min to try n purge air but still pulling code for lowe water??

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    6 ай бұрын

    Show me pictures of your boiler and I can tell you the steps.

  • @amieg178
    @amieg1782 ай бұрын

    Will this help if the system is not producing heat but the hot water is working?

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    2 ай бұрын

    Yes bleeding air out is. But you could also have a broken 3 way valve.

  • @nicalone19
    @nicalone19 Жыл бұрын

    Hi, you did not explain if you need to turn the machine off or if it needs to be on.

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    Жыл бұрын

    It's better when it is off so you don't over heat the boiler when bleeding.

  • @ozkrmoreno6781
    @ozkrmoreno67817 ай бұрын

    Hi, what happened if I do that but the pressure is 9.5?? What can I do ?

  • @TJ_HVAC_heating_cooling

    @TJ_HVAC_heating_cooling

    7 ай бұрын

    It should just fill up on its own. If you're using the built in auto feeder of Navien then you have to turn on the switch just make sure all thermostat is set lower temperature or off.

  • @TJ_HVAC_heating_cooling
    @TJ_HVAC_heating_cooling3 ай бұрын

    WATTS 1/2 inch B911-M3 threaded combination water feeder and backflow preventer amzn.to/3xra7XV

  • @TJ_HVAC_heating_cooling
    @TJ_HVAC_heating_cooling3 ай бұрын

    1-1/4" Spirovent Jr. Air Eliminator (Sweat) amzn.to/4aCvioe

  • @TJ_HVAC_heating_cooling
    @TJ_HVAC_heating_cooling3 ай бұрын

    Taco Zoning Control, 3 Zone, Expandable - SR503-EXP-4 amzn.to/4aawSxU

  • @TJ_HVAC_heating_cooling
    @TJ_HVAC_heating_cooling3 ай бұрын

    Taco 007E-F2 Emc High Efficiency Circulator amzn.to/3IYq2zx

  • @TJ_HVAC_heating_cooling
    @TJ_HVAC_heating_cooling3 ай бұрын

    AMTROL 102-1#30 EX-30 30 Extrol Expansion Tank amzn.to/3TXEcal