No video

How To Program And Wire An HY VFD (Complete Breakdown)..

This video covers a complete tutorial on programming an HY VFD along with correctly wiring it. I also cover the correct cable to use for VFD signal manipulation for spindle speed control as well as relay control to cycle the unit on, and off.
If you have questions, or require quotes please message me direct at Storm2313@gmail.com or through my eBay store here. www.ebay.com/str/edealersdirect
Here's a link to my VFD Ground Splitter www.ebay.com/itm/143429348995
Here's a link to my DS Flexion 20awg 5 lead cable to build your VFD interface cable.
CNC 20awg 5 Lead DS Flexion Ultra Flex Cable 20Ft Robotics Grade www.ebay.com/itm/133891673190
Here's links to my spindle cables, and I can of course cut them to a custom length for any application. Please message me.
If you're uncertain of the length you require use a piece of string to simulate the cable, and run it exactly where you plan to run the cable. This will assure you get the right length.
These are my standard double shielded DIY spindle cable kits.
These include all required accessories to build your cables minus the solder, flux, and your female spindle connector.
CNC VFD Cable 10ft 16/4 Double Shielded For Spindle .8Kw 1.5Kw 2.2Kw 4Kw 4.5Kw://www.ebay.com/itm/142538105021
CNC VFD Cable 15ft 16/4 Double Shielded For Spindle .8Kw 1.5Kw 2.2Kw 4Kw 4.5Kw www.ebay.com/itm/133273996534
CNC VFD Cable 20ft 16/4 Double Shielded For Spindle .8Kw 1.5Kw 2.2Kw 4Kw 4.5Kw www.ebay.com/itm/131899174942
CNC VFD Cable 25ft 16/4 Double Shielded For Spindle .8Kw 1.5Kw 2.2Kw 4Kw 4.5Kw www.ebay.com/itm/133273999194
CNC VFD Cable 30ft 16/4 Double Shielded For Spindle .8Kw 1.5Kw 2.2Kw 4Kw 4.5Kw www.ebay.com/itm/133273998565
DS Flexion ultra flex double shielded cables are below (rated to 10 million flex cycles)
These include all required accessories to build your cables minus the solder, flux, and your female spindle connector.
CNC VFD Cable 20ft 16/4 DS Flexion For Spindle .8Kw 1.5Kw 2.2Kw 4Kw 4.5Kw
www.ebay.com/itm/132649829362
CNC VFD Cable 15ft 16/4 DS Flexion For Spindle .8Kw 1.5Kw 2.2Kw 4Kw 4.5Kw www.ebay.com/itm/133891673596
CNC VFD Cable 10ft 16/4 DS Flexion For Spindle .8Kw 1.5Kw 2.2Kw 4Kw 4.5Kw www.ebay.com/itm/133891676093
#CNC #DIY #Machining #Engineering #Woodworking #Metalworking #Automation #Precision #Craftsmanship #Maker #Fabrication #Innovation #Tutorial #VFDProgramming #WiringGuide #SpindleControl #Electronics #EngineeringLife #Manufacturing #Tooling #CNCEnthusiast #DIYProjects #Industrial #Tech #HowTo #Expertise #creativeprocess #CNCProblems #Troubleshooting #CNCIssues #FixingCNC #CNCChallenges #MachiningProblems #CNCDebugging #CNCMaintenance #CNCErrorCodes #SpindleTroubleshooting #ToolWear #FeedrateIssues #GCodeErrors #CNCWorkpieceErrors #CNCSetupProblems #PrecisionIssues #CNCCalibration #CNCAlignment #ZAxisProblem #ToolBreakage #CNCSoftwareGlitches #CNCAccuracy #MachineDowntime #CNCRepairs #CNCWiringIssues #CNCCommunicationErrors #AxisDrift #MaterialFeedingProblems

Пікірлер: 65

  • @J042578c
    @J042578c7 күн бұрын

    Excellent video!! Still learning and this helped out a ton!

  • @corvetteguy50

    @corvetteguy50

    7 күн бұрын

    Thank you for your support. I really appreciate it! Vince

  • @kennethtencza9209
    @kennethtencza92094 ай бұрын

    Nice, just ordered one for my milling machine . Very good tutorial.

  • @corvetteguy50

    @corvetteguy50

    4 ай бұрын

    Thank you for your support. I really appreciate it. Vince

  • @neilberkeley5469
    @neilberkeley54695 ай бұрын

    Thank you you helped so much My spindle is now fully operational 🎉

  • @corvetteguy50

    @corvetteguy50

    5 ай бұрын

    Thank you for your support. I'm glad to hear you got it up and running. Thank you, Vince

  • @_desertwalker_
    @_desertwalker_9 ай бұрын

    Thankyou very much for this, I have a BD600 VFD but didnt understand the RST terminals. I do now

  • @corvetteguy50

    @corvetteguy50

    9 ай бұрын

    Thank you for your support. I really appreciate it. I'm glad to know the video helped :) Vince

  • @ziarehman4127
    @ziarehman412728 күн бұрын

    Amazing video very helpful

  • @corvetteguy50

    @corvetteguy50

    28 күн бұрын

    Glad you liked it! Thank you for your support Vince!

  • @user-pl2fo5xy7q
    @user-pl2fo5xy7q8 ай бұрын

    Thank you for the video!! it got my software working great controlling the spindle. I don’t suppose you could look at the Sunfair E380 from sale CNC and do a video on that could you? Even better if you can do it for the CSMIO/IP-S controller 😊

  • @carlengel2806
    @carlengel28064 ай бұрын

    This was very helpful. I have this unit and a 1.5KW water cooled motor for my CNC router. Somehow it seem to loose all setting when I moved it. This helped me set it back up. However, I am getting an error E.O.C.A.

  • @corvetteguy50

    @corvetteguy50

    4 ай бұрын

    EOCA error means the unit is experiencing "over current during ramp up" You can review the variables to create this error here www.cnczone.com/forums/attachment.php?attachmentid=120805&d=1291629472 Thank you, Vince

  • @johnpeters211
    @johnpeters2119 ай бұрын

    Love your videos, thanks for these, I have a question. I have a 110v HY VFD rated for 13A output and am setting it up now with a G-Penny 1.5Kw, 12A, 24,000rpm, air cooled spindle. When I go to set PD142 it will not let me go above 7, but my spindle is rated as 12. Any idea why it will not let me go above 7? When I try to increase the "tens place" from 0 to 1 it just takes the "ones place" back to 7 and leaves the "tens place" vlaue as 0. I do not have the spindle cable connected while I have been doing this, just power input connected.

  • @corvetteguy50

    @corvetteguy50

    9 ай бұрын

    Hey John, Thank you for your support. I recommend contacting your vendor first as they should be supporting the components they sell. If you would like to move forward with a paid consultation, I offer them as well. Please let me know if you would like to schedule one. Please understand as a vendor myself of CNC hardware as you purchased that I include support for all my client's purchase's which makes me cost more than overseas vendors on just the hardware price, but when factoring in I can, and do provide support which makes the investment justified to those requiring help in setting their hardware up. Thank you and have a great weekend! Vince

  • @SignatureMinis522
    @SignatureMinis5227 ай бұрын

    I bought the FC01 VFD and have a bridgeport 2J with a variable speed head, any help with parameters/settings would be greatly appreciated, i just need the vfd to convert 1 to 3 phase and be able to use the original FWD/ REV switch

  • @corvetteguy50

    @corvetteguy50

    7 ай бұрын

    Hye Neil, thank you for your support. The support you should be seeking is from the vendor that sold the unit to you as they should readily be able to provide it. I only support components I sell. Thank you, Vince

  • @willpartin622
    @willpartin62227 күн бұрын

    Great video, thank you! I'm wondering if it will have to be reprogramed if power is lost...also, I'm using it in a barn to run a fan in summertime, it will be off all winter. Will the unit be damaged when sitting through winter in cold ambient? Thanks again.

  • @corvetteguy50

    @corvetteguy50

    27 күн бұрын

    Thank you for your support. This depends on what you mean by "power is lost" If you're discussing a power outage from a storm the unit's settings should be reverified in best practice. If the unit is shutdown properly then the settings won't be lost. There's no way to answer your question about the fan as I have no idea what temperature your barn is in. In best practice all production robots should be operated in a climate controlled environment for longevity, and stability. Thank you, Vince

  • @callsaulusa4731
    @callsaulusa47315 ай бұрын

    I like your videos and I just order the G540 diagram and the ground splinter from your ebay store. Do you also sell the Word Document showed in this video? And, do you sell the diagram to control the spindle speed with a relay? Please let me know.

  • @corvetteguy50

    @corvetteguy50

    5 ай бұрын

    Saul, thank you for your support. I really appreciate it. I do have the spindle wiring diagram for relay integration along with 2 videos on setting it up. Please use the email in the video's description for details. Thank you, Vince

  • @edilbertomartinez5758
    @edilbertomartinez57586 ай бұрын

    How about with openbuilds control can i use youre 6 pin wire and get the same functions?

  • @corvetteguy50

    @corvetteguy50

    6 ай бұрын

    Thank you for your support. This depends on the openbuilds controller. Please contact your vendor for them, as I only support systems I build. Thank you, Vince

  • @rickgauthier6597
    @rickgauthier65973 ай бұрын

    Do you have any wiring configuration videos for 0-10v pwm signal with a pwm to analog control module from a grbl based board for one of these Chinese spindles?

  • @corvetteguy50

    @corvetteguy50

    3 ай бұрын

    Thank you for your support. GRBL, and Arduino type boards aren't to be used with CNC routers as they are USB, and universal serial bus is unstable for these types of production robotics. I cover this many times in my CNC fail video series. Here's my latest CNC fail video showing what typically happens when using USB kzread.info/dash/bejne/h2qIsa1mo5POfto.html This video like many others in my fail video series covers an email direct from the largest manufacturer of USB motion controllers CNCdrive out of Hungary. Their lead engineer Balazs covers what issues USB has with grounding, and stability. I highly recommend you proceed with caution with what you see on social media using these types of boards as many content creators simply have no idea what they're doing, and only mimic what others have done in videos. Thank you, Vince

  • @travijay229
    @travijay2295 ай бұрын

    I am using this vfd for single to 3 phase conversion. 3hp 9amp air compressor, do i need to program the vfd?

  • @corvetteguy50

    @corvetteguy50

    5 ай бұрын

    Thank you for your support. Yes, all VFD's require programming to your spindle, or application. Thank you, Vince

  • @brettbkeogh
    @brettbkeogh7 күн бұрын

    Thanks so much for the video. Would this apply to setting up the VFD for a wood turning lathe, .75Kw 415V 3 phase motor with 240V single phase power supply, lathe spindle speeds from 350 rpm to 3500rpm. Cheers

  • @corvetteguy50

    @corvetteguy50

    6 күн бұрын

    Thank you for your support. The settings provided in this video are for HY VFD's. If yours is a different brand then you'll have to review its users manual, and or contact its vendor for the correct settings. Thank you, Vince

  • @derekjenkinson8014
    @derekjenkinson80146 ай бұрын

    Is this set up the same if using the pwm control for a Longmill?

  • @corvetteguy50

    @corvetteguy50

    6 ай бұрын

    Please ask them if you're using one of their systems. They should offer you support for setting up a VFD they're a vendor of. Thank you, Vince

  • @CyrPerformance1
    @CyrPerformance127 күн бұрын

    Found your channel and after watching a few others videos, yours is by far the most informative. I have this VFD and wonder if you would be willing to help me with a remote control setup.

  • @corvetteguy50

    @corvetteguy50

    27 күн бұрын

    Thank you for your support. I offer consulting. Please contact me from the video's description, and we can set one up. Thank you, Vince

  • @CyrPerformance1

    @CyrPerformance1

    27 күн бұрын

    ​@@corvetteguy50not seeing how to contact you in description? Went to About and don't see anything there.

  • @corvetteguy50

    @corvetteguy50

    27 күн бұрын

    My information is listed under the video's description Storm2313@gmail.com Thank you, Vince

  • @CyrPerformance1

    @CyrPerformance1

    27 күн бұрын

    @@corvetteguy50 got it, sorry, sent email.

  • @user-vr3th2jo3b
    @user-vr3th2jo3bАй бұрын

    Hey thanks for the video, I went through and changed all the parameters to the recommended settings in the video and when I run the spindle it starts for a second and then gives me the eoca error any thoughts. Should I reach out to the manufacturer it's brand new or am I missing something here any insight would be great if possible,thank you.

  • @corvetteguy50

    @corvetteguy50

    Ай бұрын

    Yes, always reach out the vendor who sold you the unit as you're the only one who can hold them accountable. I suggest referring to the users manual as all the errors are located in it to define your problem. Your error deals with an over current issue. Thank you, Vince

  • @user-vr3th2jo3b

    @user-vr3th2jo3b

    Ай бұрын

    @@corvetteguy50 awesome thanks again hopefully I can get it figured out.

  • @corvetteguy50

    @corvetteguy50

    Ай бұрын

    You bet...:) Thank you, Vince

  • @user-vr3th2jo3b

    @user-vr3th2jo3b

    Ай бұрын

    Hey sorry to keep bugging you I got the spindle running but it's maxing out at 12000 Rpms do you know what parameter I would possibly change to get it up to 24000 thanks again. The information online is so vague.

  • @corvetteguy50

    @corvetteguy50

    Ай бұрын

    Please review the video in conjunction with your users manual as its covered in it. We can also setup a consultation if you still require assistance. Thank you, Vince

  • @aticafloorable
    @aticafloorable5 ай бұрын

    Mr. The frequency in the USA is 60 HZ AND THE FREQUENCY OF MY MOTOR IS 50 HZ. THE PARAMETERS P0.03 60HZ, PO.O4 60HZ, P0.06 60HZ, AND FOR THE MOTOR P2.02 50HZ Is this correct? my gt vfd is 5kw 7.5hp thanks

  • @corvetteguy50

    @corvetteguy50

    5 ай бұрын

    Thank you for your support. Please contact your vendor for support as they should provide it for free. I offer third party support for a fee. Thank you, Vince

  • @PSS_1
    @PSS_126 күн бұрын

    How to change the spindle turnover, I have LEFT all the time and I want to change it to RIGHT

  • @corvetteguy50

    @corvetteguy50

    26 күн бұрын

    The answer is in the users manual on page 14. The diagram in the video also reflects REV switch on the units digital interface which controls this. Thank you, Vince

  • @cameronsnyder9042
    @cameronsnyder90428 ай бұрын

    So, I am following the steps on how to program. My issue is that it won’t let go to PD013 to=8 When I switch it to PD and then set it to 03 hit shift so that I can switch the 0 to a 1 making it 13 my VDF makes it 00 or 09. Any assistance would help!

  • @TheStoryist

    @TheStoryist

    8 ай бұрын

    Assistance should come from your vendor, and if you bought it from Vince I'm sure he'll get with you.

  • @corvetteguy50

    @corvetteguy50

    8 ай бұрын

    Thank you for your support. I'm sorry you should contact your vendor first about the issue as I don't have you as a client of mine that purchased a VFD. Thank you, Vince

  • @cameronsnyder9042

    @cameronsnyder9042

    8 ай бұрын

    @@TheStoryist I purchased it on Amazon and happened to comment here as it was the most informative video. Just seeing if he may have clarification although it’s not his product.

  • @stephenkanyojr.4042
    @stephenkanyojr.40423 ай бұрын

    you don't mention any thing about a 220 3 phase input, can you elaborate

  • @corvetteguy50

    @corvetteguy50

    3 ай бұрын

    Thank you for your comment, but your vendor is who you should be asking this question to as its their responsibility to offer you support for your components as they have your money correct? R,S,T,= 3 phase. Thank you, Vince

  • @stephenkanyojr.4042

    @stephenkanyojr.4042

    3 ай бұрын

    @@corvetteguy50 I figured that. This is the problem: I have a Huanyang HY01D523B inverter, in the manual it states that it has an input of either single or 3 phase. I have 3 phase, wired it according to instructions to a 24,000 RPM water cooled motor. The inverter powered up ok, set parameters. When I pressed the start button the inverter blew up. Can you help with this, I don't want to blow up another one.

  • @corvetteguy50

    @corvetteguy50

    3 ай бұрын

    Once again you need to reach out to the vendor that sold you the unit, and explain what you just did to me. When you explain you "set parameters" VFD parameters when set incorrectly will damage the VFD/spindle its running, and considering you said it powered on alright then you now know what blew the VFD. I only support clients that purchase units from me. Thank you, Vince

  • @bransonlariscy4660
    @bransonlariscy46609 ай бұрын

    *Buyers beware!! I just bought one of these VFD and I believe its a knockoff of the Haunyang brand shown in this video. It looks identical from the outside but the wiring is different and its not allowing me to change any of the parameters in the program. For example, it doesn't have a PD141, 142, 143, 070 or many others. I bought it on Amazon as a package kit with 2.2kw spindle and pump. After closer examination when I received I couldn't find a brand or label on it anywhere. And it didn't come with any literature or manual.

  • @corvetteguy50

    @corvetteguy50

    8 ай бұрын

    Thank you for your support. Unfortunately, this is happening more frequently. I would recommend returning it to Amazon as they have an excellent return policy, Thank you, Vince

  • @ralfkessler
    @ralfkessler2 ай бұрын

    This is not for the faint of heart. Just a little over my head.

  • @corvetteguy50

    @corvetteguy50

    2 ай бұрын

    Thank you for your support. Just take your time, and break the setup into pieces. Its much easier to digest that way. Thank you, Vince

  • @Basement_CNC

    @Basement_CNC

    2 ай бұрын

    jeah bit shocking .....if you do it wrong 😂

  • @davidarauz83
    @davidarauz8322 күн бұрын

    This guy lost Me

  • @corvetteguy50

    @corvetteguy50

    22 күн бұрын

    Thank you for your support. I suggest watching the video as many times as needed as its a lot of information to digest. Thank you, Vince

  • @huanyanginverter6516
    @huanyanginverter65167 ай бұрын

    The video is fantastic. I am the designer of this product. Please contact me. I would like to be friends with you.

  • @corvetteguy50

    @corvetteguy50

    7 ай бұрын

    Ok, thank you for your support. My channel reflects my CNC automation controller engineering business. I only use your VFD's, and spindles for my clients. Thank you, Vince

  • @huanyanginverter6516

    @huanyanginverter6516

    7 ай бұрын

    @@corvetteguy50 Which country are you from and where did you purchase the Huangyang frequency converter?

  • @corvetteguy50

    @corvetteguy50

    7 ай бұрын

    I'm from the US, and purchased it there as well.

Келесі