How To Motor Star Delta Connection | 3 Phase Motor Connection प्रैक्टिकल
Ғылым және технология
How To Motor Star Delta Connection | 3 Phase Motor Connection प्रैक्टिकल
wellcome my KZread channel srijan electrical
doston is wala video mein motor mein Kaise Star connection hota hai delta connection hota hai aur ek sath mein star delta connection Hota Hai vah Mein practically bataya hai aur motor ko kaise check Karke usmein kaun sa point mein kaun sa wire lagana hai kaise supply dena hai vah mein detail aap Ko practically dekha hai aur theory paper mein drawing Karke bataya to aap log video last Tak Jarur dekhiae to aap log ko pura video samajh mein aayega 3 phase motor mein Kaise connection karna hai
thank you all friends
please like comment share and subscribe
#motorconnection
#star_delta
#srijan_electrical
Пікірлер: 71
Good information & nice video
@Srijanelectrical
Ай бұрын
Welcome thank you so much for your support me🙏🙏
Very good Very informative video I love this video, very clearly explained
@Srijanelectrical
4 ай бұрын
Welcome🙏 Thank you so much for your support me👌
Thankyou sir
@Srijanelectrical
Ай бұрын
Welcome friend Thank you so much for your support me🙏
Sir very nice video aache se aaya shamh me
@Srijanelectrical
3 ай бұрын
Welcome 🙏 Thank you so much for your support me🙏🙏
15 hp motor connection video bonao bhai
@Srijanelectrical
2 ай бұрын
15 hp star Delta connection asisa karne ka
Bhut accha laga hai sir
@Srijanelectrical
7 ай бұрын
Thank you so much for your support
Thank you dear sir,🙏
@Srijanelectrical
3 ай бұрын
Welcome🙏 thank you so much for your support me
Good sir ji
Thanku so much sir 🙏
@Srijanelectrical
5 ай бұрын
You're welcome, for your support me
Thanks ❤❤❤
Good
@Srijanelectrical
7 ай бұрын
Thank you so much for your support
Very good sir
@Srijanelectrical
7 ай бұрын
Thank you so much for your support
, 100 video dhekne ki baat,,, app ka video me full samsa ... Thanku
@Srijanelectrical
8 ай бұрын
thank you so much 🙏
Very good 👍
@Srijanelectrical
7 ай бұрын
Good morning, thank you so much for your support
Good sir ji 🙏
@Srijanelectrical
5 ай бұрын
Thank you so much for your support me👌👌
V good...
@Srijanelectrical
6 ай бұрын
Thank you so much for your support
Good experience
@Srijanelectrical
7 ай бұрын
Thank you so much
nice video bro
@Srijanelectrical
6 ай бұрын
Thanks for the visit
🎉🎉🎉🎉 Very good Experience Sir ji
@Srijanelectrical
6 ай бұрын
Thank you so much for your support...
If voltage is 128+128+128 how to use ..star or delta
Sir 15 hp kaa moter ko star delta me connction to kr diya aapne ab aage isko konse starter se chalana h dol starter yaa dusra koi starter se ple btaye sir
@Srijanelectrical
13 күн бұрын
@@Kamleash821 5-7hp motor dol starter Chala sakte hain 15 HP ka motor hai to start Delta starter use Karke chalayega to Bater hai Nahin to vfd se bhi motor Chala sakta hai
Sir main contactor aur delta contactor ka cable dono point me kidhar bhi Laga Sakta hai kya example main contractor U1 R , V1 Y, W1 B, delta contactor cable U2 B, V2 R ,W2 Y isi tarah se connection kar sakte hai kya
@Srijanelectrical
Ай бұрын
Ha aap connection kar sakta hai aap jis tarike se comment Mein bataya mere ko hai is tarike se aap connection kar sakta hai friend
Bhai star delta starter ke sath batao kaise star r delta kiya jata h ek motor ko
@Srijanelectrical
6 ай бұрын
👌okay, thank you so much for your support me
Sir.... Agar same coil me same phase lagayega to kya problem hosakta hai ???
@Srijanelectrical
Ай бұрын
Delta Contactor Jaisa pickup Hoga Usi time motor trip ho jaega
Bhaiya 75 kb ka motor hai aise hi connection kar de...
@Srijanelectrical
4 ай бұрын
75 kw मोटर same star Delta connection kar sakta hai, lekin iska speed control karne ke liye vfd drive Laga sakte hain
Good information
Bhut acche se samjaya
@Srijanelectrical
7 ай бұрын
Thank you so much for your support
Apki awaj me bangali tach aa raha hai
Sir neutral kahanse milega
@Srijanelectrical
5 ай бұрын
star point se
sir R Y B phase ko kisi bhi sequence main laga saktay hain star wali side be or Delta wali side pe? ya jaisay video main hai ushi terha lagana hai? thanks mera ye matlab ye hai Red wire ke samnay Red or yellow wire ke samnay yellow or aisay hi blue ke samany blue. laga saktay hain?
@Srijanelectrical
Жыл бұрын
Friends R Y B Tina phase ko Kisi bhi sequence main laga sakta hai motor ka Star connection mein And delta connection mein Aur star delta mein job connection Karega top aapko motor ka 2 point mein Jaisa video mein bataya Hai pahle aap ko pata kar lena padega uska hisab se aapko supply Dena padega matlab motor mein teen winding rahata Hai usmein Ek winding Mein Do point Hota Hai Ek point mein aap main contactor ka R phase supply motor ka U1 dega to aur ek point mein Delta contactor ka Y phase U2 dega okay
@MAbid-zt7nm
Жыл бұрын
@@Srijanelectrical pper aap ne kaha ke ( main contactor ka R phase supply motor ka U1 denga to aur ek point mien Delta contactor ka Y phase U2 dega ) iski jaga hum U1 per R phase ki jaga B Phase or U2 per Y phase ki jaga R phase laga saktay hain Sir OLR full load ke hisab se hogi. meray star delta starter main 12 to 18 amp ki relay lagi hai motor ka fla Hai 14 amps to kya ye OLR theek hai? OLR contactor ke baad lagi hai please help or sir phlay jab 7.5 kw ka motor delta connection pe chalaya tha tab per phase 14.5 amps leta tha ab jab clamp meter se check kertay hain to main contactor wali side or delta contactor side dono per phase 6.5 to 7 amps show kerta hai. to kya star delta starter se electric consumption bhi kam hogi ?
@Srijanelectrical
Жыл бұрын
@@MAbid-zt7nm haa Laga sakta hai, (aap video achha se aur ek baar Dekhi ,motor ka 6 terminal hai U1 ka Sidha u2 to nahi hai O cross mein Laga Hai)
@Srijanelectrical
Жыл бұрын
@@MAbid-zt7nm ha thik ha OLR Contactor baad o thik hai, but motor job amp setting karna hai to OLR mai tob motor name plate dekhne ka usmein likha rahata hai motor minimum current Kitna lega aur Maximum current Kitna lega uska hisab se setting karne ka. Okay
@Srijanelectrical
Жыл бұрын
@@MAbid-zt7nm na, motor Jab Runing Hoga Usi time mein starting Mein Thoda Jyada current leta hai uska Baat ek minimum range mein current leta hai
Moter ulta chle to kiya krna tha stardelta ek sath mai
@Srijanelectrical
10 ай бұрын
Motor ko power supply dene ke liye Jidhar aapka input supply ka terminal box hai Udhar aapka R Y B phase connection hai ,too aap udher R phase ko fixd rakhiye, Y phase aur B please ko alternet kar dijiye to Aapka motor Sahi direction mein ghumega.
Star connection main neutral kider lagaya hy ..?.
@Srijanelectrical
Жыл бұрын
Motor mein aap job Star connection Karega apne Dekha hoga terminal Hota Hai Jaisa Hamara u1, v1,w1 aur ek side mein u2 ,V2, w2 to Aapka eksath Mein teeno terminal ko short karna padta hai tab jaka aapka Star connection banta hai aur ek side mein aapko 3 phase power supply Dena padta hai to Jidhar Apne short Kiya Hai Udhar aapka neutral point ban jata hai , to star connection Mein Aisa Hota Hai
@waheedislam2989
Жыл бұрын
@@Srijanelectrical kis bhi k sath ..?.
@Srijanelectrical
Жыл бұрын
@@waheedislam2989 star connection in motor U2, V2, W2 sath. Matlab 3 winding jo rahata hai ek ek winding ka 2 point Hota Hai to teenon winding ka ek ek end point short kar Dene Ka top star connection ho jata hai, u2, v2, w2...
Cannection kaise kore ..
Good
Good
@Srijanelectrical
7 ай бұрын
Thank you so much for your support