How to modify your air compressor to run air tools or impact wrenches

I troubleshoot my small air compressor and fix the CFM issues so I can use an impact wrench at full power.
3/8 air regulator I used was same brand as this one (not available at this time www.amazon.com/PneumaticPlus-... )
So I would order this one
www.amazon.com/dp/B01F2VGPEG/...
The air filter is a 1/2 NPT and this is what I used
www.amazon.com/gp/product/B01...
Remember to purchase the required pipe fittings to be able to plumb this together. Once you open up the air flow thru your air lines you will be able to drive impact guns to full power. It won't work for DA sanders and such because they are continuous use tools but an impact gun doesn't run full time. The small air compressor will be able recharge before you hit the next tire on your car.

Пікірлер: 409

  • @stevenkroot31
    @stevenkroot31 Жыл бұрын

    Hi, good video. A couple suggestions, #1 - get rid of all the 90 degree fittings, high speed air hates to turn corners. Why do you even have that last 90 between the hose and regulator? #2 - get rid of all the extraneous fittings, your test air pressure gauge has a female quick disconnect, a male QD, the gauge, a pipe nipple, a female QD, and a male QD. For demonstration just run the hose into the gauge and the gauge into the tool. You will find without all the corners and fittings there will be much less drop in the lines (and fittings). The advantage to less drop between your compressor and your tool is less condensation in your lines and less water in your tools. Your on the right track, just need a few tweaks.

  • @PaulThomas-qo9vy

    @PaulThomas-qo9vy

    Жыл бұрын

    Yes good job on recognizing all the flow restrictions you corrected in the vid.! But sharp 90° "drilled" fittings are terribly restrictive! Even a standard threaded plumbing "elbow" is LESS restrictive than those "drilled" brass 90° fittings. I saw a 20 psi Increase in fuel pressure on a test engine fuel system after removing 4 sharp 90's & replacing them with a hose to make the bend. My ex-Navy mechanic co-worker friend showed me that (thanks Craig). Again on another test engines external oil system I suggested to my engineer to remove 3 sharp 90's & he got 14 psi Increase ! Air behaves like a fluid (examine/study Fluid Dynamics), so the more smoothing or elimination of bends the better! A helpful, educational,compressed air KZread channel is THE Compressor Guru, Bud Stiner, enjoy! Paul from S. Central Tx.

  • @sandasturner9529

    @sandasturner9529

    Жыл бұрын

    You sound like my mom.

  • @monadking2761

    @monadking2761

    Жыл бұрын

    Saw the same problems with the 90s. Air is a fluid and 90s restric the flow. If you want the regulator and separator in the same location take out the 90s and bend some copper pipe to a U bend over a larger radius with compression fitting on the outside of the pipe. You will have more flow.

  • @jonnyshoestring9368

    @jonnyshoestring9368

    Жыл бұрын

    New to compressors but having done quite a bit of plumbing, I always find it improves the water flow if sweeping- bends are used, those are less acute than the 90° bends which act as buffers. I think 1/2 copper pipe will take about 150psi.

  • @PaulThomas-qo9vy

    @PaulThomas-qo9vy

    Жыл бұрын

    @@jonnyshoestring9368 I agree! The larger & smoother the turn radius, the less restriction. On the video, he had eliminated many restrictions & improved air flow significantly. However several of us saw the worst restrictor 90° fittings possible in his new plumbing & suggested eliminating them for more improvement. I have cut several fittings in half (axially, in alignment with the flow direction), & was shocked to see those brass fittings were actually drilled internally! Any fluid, liquid or air slams into a wall & then tumbles around the sharp corner, losing velocity, pressure & thus volume downstream! Even a std. 90° NPT galvanized plumbing "pipe" elbow has a Radius inside it & is Less restrictive than those brass "drilled" 90°el's. I only used those in a non-flowthru application (like a gauge or pressure sensor), once I understood this. I understand you know this but I wish younger mechanics/plumbers could learn this too. About Compressors, a great KZread teacher is Bud Stiner on THE Compressor Guru! He has 41 years of compressed air systems design, upgrades, repair, rebuilds & water removal technology. Nice, funny guy & smart too! Cheers, Paul

  • @benniedonald
    @benniedonald2 жыл бұрын

    This is a great video and truly explains this problem. In a visual way for people to see and hear what is going on.

  • @markbernier8434
    @markbernier8434 Жыл бұрын

    As a lot of air tools are intermittent use, nailers and the like, I've had good success with leaving a compressor stock, running any old hose to the site (like foot of ladder) then plugging in an air pig fitted with 1/2 in hose. The reservoir has no restrictions and lets the small compressor cycle better while providing lots of flow to the tool only as needed.

  • @joanfrellburg4901

    @joanfrellburg4901

    Жыл бұрын

    I really like this idea. I'm going to modify my air pig and give this a try. Thanks !

  • @RichadTheLionHeat
    @RichadTheLionHeat2 жыл бұрын

    Absolutely concur with the comments below from an other video. Extremely valuable, educational, informative, detailed, your process of trouble shooting is well latex out, which aid me to increase my knowledge on air compressor, hoses and air guns, I very much appreciate your time, efforts you took to assist many many viewers. I am sending your video to many of my family, friends, co-workers, and hardware and tool supply personnel that I know. Blessings to you, your channel. With very much appreciation, thank you. 👍🏻😉🙏🏻🇺🇸🙏🏻🇺🇸🙏🏻🇺🇸🙏🏻🇺🇸🙏🏻🇺🇸🙏🏻. .

  • @galley3175
    @galley31756 ай бұрын

    This is one of the most explanatory videos about how the compressor pipes and lines impact pressure at the tool. I just bought the same 30 gallon compressor and an impact gun, and was stumped by why the torque was so low. We looked at the manufactures website and they showed that a higher pressure might be needed, but they did not go into detail about how the 1/4 piping on the compressor could cause this issue. This video makes perfect sense, and is an amazing video that should be one of the first videos someone watches if their new to impact guns. Great Video!

  • @Tonyplat98

    @Tonyplat98

    4 ай бұрын

    You can't run an impact on a compressor like that. It's never going to be anywhere near what it's capable of. You're way better off purchasing a cordless battery powered impact it will work way better and give you way more power. In order to run these tools the way they're supposed to you need at minimum 5HP air pump those compressors run in the thousands of dollars... Good luck to you though!

  • @majorpayne5289
    @majorpayne52892 жыл бұрын

    VOLUME vs PRESSURE. Big difference.

  • @bad406camaro
    @bad406camaro Жыл бұрын

    30 years ago when I was setting up my garage (just purchased house) I used all 1/2 pipe to run air to 1 inside and 1 out side hose reels I found the same issue with the smaller Craftsman air compressor I had at the time. With the style compressor I had I was able to use a 1/2 in ball valve right off the tank. I continued to run my compressor operating pressure at maximum 155 psi per the tank ratings. I regulated air down to 110 psi where the steel pipe ended at the hose reels. The hose reels were 3/8 Once the initial fill of the tank was done the compressor never struggled to maintain pressure for air tool use. I eventually ran out of CFM capabilities of the Craftsman and upgraded to IR industrial 80 gallon as my air needs expanded. But I never needed to change the pipe or regulators. What you describe here is a Valuable investment proven over time

  • @BuildItFixItDIY
    @BuildItFixItDIY Жыл бұрын

    Thanks for that video. Many months ago I decided to, and purchased fittings to do the same to my 25 gallon portable compressor. I was going to drill out and re-tap the compressor bung, but I know what you mean about the mentality surrounding that. We’ll see, I haven’t had time to work on it since then.

  • @G5Hohn
    @G5Hohn Жыл бұрын

    Echoing the comments about reducing the number of fittings and especially all those 90s. I wanted to point out that your “improved” setup on the new compressor has the regulator and filter plumbed backwards. The regulator ALWAYS goes after the filter. This is so that 1) filter pressure loss is excluded and 2) regulator is protected. Finally, on your new compressor setup, move your regulator as far downstream as possible. It’s much more efficient to transmit air at 175psi than at 100psi. Running max pressure as close to the end as possible will slash the line losses. I run a large Nitrocat 1250K on a 120v compressor across a 3 car garage and see only 15psi drop at the gun, regulator set at 120 (max setting) I still get 105 at the gun. This is because my regulator has been moved to the end of 25ft of 1/2” air hose and I only have 15ft or so of 1/2” hose between regulator and tool. I’m very happy with it.

  • @robertkerby2581
    @robertkerby2581 Жыл бұрын

    Great upgrades! Well done!

  • @Danny-vu7bb
    @Danny-vu7bb2 жыл бұрын

    That was pretty good mister. Thank you for taking the time to make this video.

  • @wesleydeer889
    @wesleydeer889 Жыл бұрын

    Awesome awesome video, you answered so many question. For years I wondered what kinds of pressure drops the 1/4 and 3/8 would cause. Even with a clean setup looks like 1/4 isn't good for much.

  • @Psikeomega
    @Psikeomega Жыл бұрын

    A booster tank 5 feet from your work area tied into your air system always works well with a 3/8 hose as your terminal run. The air is much happier coming out of that close tank with better pressure and volume. Then it has a better chance of a speedy recovery from the main tank when you stop. Also has the benefit of increasing your air reserve.

  • @darrellsomers5427

    @darrellsomers5427

    Жыл бұрын

    Correct a small compressor say 20 gallon 5 hp could do wonders with anather 40 gallon tank added to it I see alot of guys do that for a complete paint job on a car

  • @Psikeomega

    @Psikeomega

    Жыл бұрын

    @@darrellsomers5427 extra tanks next to your compressor do wonders. But what's nice about having a booster tank right next to you with a short whip on it, is that you can put a larger diameter hose on it for running heavier tooling and you get extra impulse from the air in the close reservoir not having to push all the way down your long hoses. You might just need to take a moment every now and then when running tooling too big for your air system for the booster to recover

  • @ifonlysolutions4011

    @ifonlysolutions4011

    6 ай бұрын

    What size booster tank generally?

  • @Psikeomega

    @Psikeomega

    6 ай бұрын

    @@ifonlysolutions4011 mine is normally one of the little 3 gallon tanks. Just be advised that the tanks really aren't meant for that, so you might be voiding your warranty to take a portable tank and convert it to a booster tank.

  • @immanutt4442
    @immanutt4442 Жыл бұрын

    When a said pipe size is doubled the volume is Quadrupled - henceforth when a said pipe size goes up to the next size then the volume is doubled . Hose size is #8 = 1/2" #4 = 1/4" #6 = 3/8" #12 = 3/4" #16 = 1" ... and so on Tubing is measured by the outside diameter A good reference is the Industrial Suppliers MSC and or McMaster Carr - they do a fine job of explaining almost all the questions one may have for given situations on upgrading tweaking and planning

  • @AMMA-we3zz
    @AMMA-we3zz2 жыл бұрын

    The reason smaller compressors use a 1/4 fitting is that you don’t quickly run out of air and the compressor runs for ever. Changing to 3/8 or 1/2 drains you tank much quicker. Certainly, 3/8 and 1/2 provide more air pressure but a price. Thanks for your efforts and explanation. Well done.

  • @007connecticut

    @007connecticut

    2 жыл бұрын

    The reason I done the video (I don't recall I said this in the video ) I had service done on the truck . Later I wanted to rotate my tires but I couldn't get the lugs loose with my impact gun. So I modified the large compressor so I can unscrew the lugs. Then for fun I wanted to see exactly where the bottle neck was and went thru the motions on video to get the CFM up on the older smaller machine as well. Just a few moments of good air flow is all you need sometimes to get really tight lugs loose. Also for occasional use impact guns this works fine. No need to spend several thousand dollars when a cheap modified compressor will do the job.

  • @mrimmortal1579

    @mrimmortal1579

    Жыл бұрын

    Right, right…. I get it… But dude, if my wife ever sees this, I’ll never be able to justify getting a newer, bigger compressor once I get my garage built. You’re killing me here!

  • @joseaguinaga7670

    @joseaguinaga7670

    Жыл бұрын

    @@mrimmortal1579 Tell your wife you NEED a bigger compressor , she will let you buy it.

  • @mrimmortal1579

    @mrimmortal1579

    Жыл бұрын

    @@joseaguinaga7670 sadly, that’s not how the game is played. What I’ll have to do is wait for a project that she wants completed, and then convince her that my older, smaller compressor isn’t up to the job, and that I can’t do it without a newer, bigger compressor. It will also help if I over-inflate (pun intended) the estimate for the project, so that it looks like the compressor costs much less than it really does. Then I just have to hope that she doesn’t see through my schemes. It’s all a very delicate and complex dance, and one wrong step can leave me turning a wrench by hand, like some kind of caveman.

  • @jimmyjamessac7171

    @jimmyjamessac7171

    6 ай бұрын

    Evil

  • @KenE808
    @KenE808 Жыл бұрын

    Excellent examples, and great explanation. Thank you!

  • @mrblack61
    @mrblack612 жыл бұрын

    Thanks for going through that. Im just resetting up lines and compressor at my place and this helped me get some understanding of where the restrictions are. Ive a few old air tools that I considered pretty crap back in the day, looking forward to see how they go with decent pressure at the business end. Cheers D

  • @paulreynolds8255
    @paulreynolds82552 жыл бұрын

    Explained very well! Thank you.

  • @Tmrfe0962
    @Tmrfe0962 Жыл бұрын

    Always wondered why my impact wouldn’t remove the lugs on my cars….thanks great video

  • @bigron26048
    @bigron26048 Жыл бұрын

    Great video, loved it, you can learn a lot from it!

  • @lillteflipguy
    @lillteflipguy22 күн бұрын

    Very informative, thanks! I was having the same issue with my compressor/impact set-up.

  • @jtn-minn8105
    @jtn-minn8105 Жыл бұрын

    Got air tools in the farm shop that are 25 years old, we've always ran direct off the compressors 175 psi 1/2-3/4 and 1'' guns...never had any problems, most farm shops I've been do the same thing.

  • @JeffAboularage

    @JeffAboularage

    Жыл бұрын

    I agree. When I build my shop, I’ll run a straight 1/2 inch straight copper pipe down the wall and right off into the work bay on a short 1/2 inch hose.

  • @patrickneenan9798
    @patrickneenan9798 Жыл бұрын

    Thank you brother. I really appreciate this tip and informative Video. Will be upgrading asap 🙏🏼

  • @Subgunman
    @Subgunman Жыл бұрын

    Had a similar issue in trying to remove the nut to a washing machine tub. Since I still use 1/4” fittings I just bypassed the regulator which was the first bottleneck and the main bottleneck, running through 25 feet to the impact gun, I had negligible pressure drop at the end of the hose. 150 psi at compressor and when the gun was activated saw pressure at the gun drop from 150 to 85 psi. Impact gun works just fine. I use this system ONLY for this impact gun.

  • @marshallguerra1353
    @marshallguerra1353 Жыл бұрын

    Great information. I will come in handy with my small compressor

  • @joehead1294
    @joehead1294 Жыл бұрын

    Solved my problem by removing original regulator and installing a tee and reinstalling the regulator after the tee. Quick connect coupling on tee and regulator with male QC on end of hose. When I need high demand/flow I move the hose to the tee, and run unregulated pressure to tool. Most of the time the hose is connected to the regulator, which I found to be too restrictive of cfm for some tools.

  • @terrymarsh1255
    @terrymarsh1255 Жыл бұрын

    You identified the obvious problems but, as has been said. every fitting, bend or filter will cause pressure loss. Try and get rid of as many of the bends as possible, you may be able to run larger bore flexible hose to make your connections. Easy bends offer less restriction than 90 degree ones. Also every join is a potential air leak so the fewer the better.

  • @jeffro221
    @jeffro221 Жыл бұрын

    Very informative. Thank you.

  • @cardo1111
    @cardo11112 жыл бұрын

    As always nice tools and fabrication work 👍🏽

  • @zsezzs1
    @zsezzs13 жыл бұрын

    Thanks for the demo!

  • @thewholls7176
    @thewholls7176 Жыл бұрын

    Good on your mate good video I’ve got one of those Ingersoll rand exact same rattle guns they are an absolute powerhouse even with the bigger bore lines I’m surprised you had trouble to be honest because you’re only taking off wheel nuts but then again it is on a truck I run nine mil hose the red one you’ve got there and the fittings are called NITTO they are high flow and I set the compressor to cut out at 160 PSI so when it’s fully pumped the rattle gun will get a blast full power for awhile as it needs 90psi so 150 ish for a few seconds that should be heaps to take wheel nuts off and compensate for air line leaks my wheel nuts are at 90 foot pounds and those guns can do 1100 foot pounds in reverse All the best from Melbourne Australia

  • @douglasburchat3304
    @douglasburchat3304 Жыл бұрын

    Some of your previous comments are absolutely correct your choaking off way to much volume with your plumbing, larger is much better and be mindful of all those 90 degree fittings. Pressure is a restriction to flow , an impact or high volume air tool needs volume. Try a 1 in impact on that little craftsman , lol 😆

  • @jameszukowski6708
    @jameszukowski67083 жыл бұрын

    This is awesome. Thank you

  • @mahmoudalphysics7494
    @mahmoudalphysics74942 жыл бұрын

    that is very helpful, thanks for your effort Sir

  • @TheMiller607797
    @TheMiller6077973 жыл бұрын

    Great informative video thank you for doing this

  • @007connecticut

    @007connecticut

    3 жыл бұрын

    Just don't use those Milton fittings. IIn a later video I use 3/8 fittings which are much much better. The Milton are too soft.

  • @Michael-w8v
    @Michael-w8v2 жыл бұрын

    That is why it is important to make sure air compressor CFM is higher than air tools' CFM requirement.

  • @007connecticut

    @007connecticut

    2 жыл бұрын

    You just got to make sure the air flows out of the tank faster than the air tool is using it up. So by changing out the hoses, piping regulator and filter the air tool has the volume of air it wants. If your compressor CFM ("Horse Power") is lacking well you will a have to let the pressure build up for your next lug to remove. At least your running the gun at full power.

  • @Michael-w8v

    @Michael-w8v

    2 жыл бұрын

    @@007connecticut Yes, it should be 3/8" I.D.; however, that is less concerned than PSI and CFM.

  • @olivercooney6645

    @olivercooney6645

    2 жыл бұрын

    Wish my small 3 50 lt tank was bigger so i could use air tools don't have space for 100lt tank

  • @kris8263

    @kris8263

    Жыл бұрын

    @@007connecticut CFM is actually the volume of air or how much air is flowing, PSI is the pressure at which the air is compressed in the hose or the tank and the HP is an engine power metric used to fill in the tank and is unrelated to CFM.

  • @007connecticut

    @007connecticut

    Жыл бұрын

    @@kris8263 correct

  • @carlosdanger1843
    @carlosdanger1843 Жыл бұрын

    Well done…good advice, sir!

  • @billmoran3812
    @billmoran3812 Жыл бұрын

    You need to relocate that filter ahead of the regulator. It’s adding a lot of pressure drop. If that same pressure drop was relocated ahead of the regulator, the effect goes away.

  • @mariocooldude9092

    @mariocooldude9092

    Жыл бұрын

    And it's not really needed unless he's painting cars and then it's too damn close to the tank how he has it mounted...water forms as the air travels down the damn hose as it cools 😂 this guy is brain dead

  • @rodhanks3914
    @rodhanks3914 Жыл бұрын

    thank you. this is just what the doctor ordered

  • @georgewebster6035
    @georgewebster60353 жыл бұрын

    Thanks for the info!

  • @watercop5115
    @watercop51157 ай бұрын

    Very good demo Thanks

  • @edups3307
    @edups3307 Жыл бұрын

    This helped a lot, thanks

  • @rdaugherty52
    @rdaugherty522 жыл бұрын

    I give you a thumbs up just the information I needed thanks.

  • @007connecticut

    @007connecticut

    2 жыл бұрын

    Larger piping and hoses make impacts run like a tire shop

  • @hunterhryciuk3964
    @hunterhryciuk3964 Жыл бұрын

    I bought this fittings the purple Milton high flow fittings I love those fittings amazing fittings will always buy more Milton fittings

  • @robertthompson3447
    @robertthompson3447 Жыл бұрын

    One day, for reasons, I needed air 300 ft away from my air compressor. Using a Y fitting and a cheap 5 gallon air tank, I set up a buffer tank near my end of the line.

  • @randywl8925

    @randywl8925

    Жыл бұрын

    Great idea.

  • @dennismolina2339
    @dennismolina2339 Жыл бұрын

    This video is godsend! Thanks!

  • @skullandcrossbones65
    @skullandcrossbones65 Жыл бұрын

    G'day, Lots of things go into a good air supply. So often people just try using a bigger capacity compressor rater than addressing the actual problems. I know a farmer who had trouble with a loader that kept overheating. He wanted to do lots of expensive repairs to the cooling system to try and fix the problem. I told him to get the leak in the bucket control valve fixed and that would eliminate a lot of the heat being generated. He had trouble comprehending the relationship between the 2 problems.

  • @makosharkcnc7730
    @makosharkcnc77303 жыл бұрын

    thanks great tips!

  • @beardy4831
    @beardy4831 Жыл бұрын

    I just switched out the 3/8 x 50ft hose for a 1/2" x 25ft hose and I can fairly happily run a 3/4" impact gun. The 1/2" impact is full blast.

  • @kris8263

    @kris8263

    Жыл бұрын

    Did you have regular fittings on the 3/8 hose or high flow? I got a 3/8 x 25 hose from harbor freight making sure there aren't any restrictions inside the crimped on threaded ends and put high flow 1/4" fittings on the compressor, hose and the gun. The air volume and speed of the gun improved noticeably over the plain 1/4" brass fittings.

  • @beardy4831

    @beardy4831

    Жыл бұрын

    @@kris8263 Probably regular fittings. The 3/8 hose was either from Home Depot or came with the compressor and has original factory fittings. I also run the tools at about 100psi instead of 90psi to help account for the hose and fitting pressure losses.

  • @raymondjackson6069
    @raymondjackson6069 Жыл бұрын

    Very good! I use 1/2 copper in my setup and home shop, but it won't be too hard to put larger fittings on some of the outlets. Didn't know the flow made that big a difference.

  • @soundman6645

    @soundman6645

    Жыл бұрын

    ya need to be very careful about using copper for air lines. The copper you use MUST be rated for the pressure and the purpose AND correctly terminated.

  • @raymondjackson6069

    @raymondjackson6069

    Жыл бұрын

    @@soundman6645 I researched it pretty good, and copper pipe was the best. I used all "L" (blue) which is the hardest you can buy at the home centers. It was that vs PVC. I learned the PVC could burst and send shrapnel all over the place. Copper splits when it fails. What is the danger you find with copper?

  • @soundman6645

    @soundman6645

    Жыл бұрын

    @@raymondjackson6069 There are some very real dangers with incorrect copper. My friend Barry, used to contract air plumbing and compressor installations, for a large compressor company. Large company, large compressors. he quoted an installation and did not win the job. He was later called back to redo the work after, the low price job failed disasterously. A section of copper pipe fractured at full pressure. It flailed around, chopping everything in its way including timber roof trusses. It was very fortunate nobody died or was injured. The copper used was the incorrect product. He did a complete reinstall with the correct grade of copper and appropriately rated fittings. I would never use rigid PVC pipe. Galvanised steel pipe is easier for "do it yourselfers" to deal with. Buy the pipe sections pre threaded.

  • @phillipvansickle4220

    @phillipvansickle4220

    Жыл бұрын

    I have a small 900 sq ft shop and use a 7.5 HP 80 gallon compressor. I use type M coper with standard leadfree plumbing solder. 3/4 for the mainline coming from the compressor and 1/2" for the drops coming from the top of the mainline. It's relatively inexpensive and the fittings are available anywhere. It's also much easier to install than black iron pipe. The pipe acts like a radiator and sucks the heat out of the air too, so I do not have problems with moisture in my lines (I do a lot of blasting, cutting and grinding). I'm more than comfortable using it for my application (I did my research). Check out the copper institute's Copper Tube Handbook.

  • @raymondjackson6069

    @raymondjackson6069

    Жыл бұрын

    @@phillipvansickle4220 Wow, that's incredible. Mise is already 1/2" through and through, and so far it hasn't given me any problems. One guy was saying it (copper) could actually shatter. I never heard of that, but will beware. I DID NOT use PVC because of possible catastrophic rupture, via the internet grapevine. Having worked with PVC I could see that happening. Copper is a much better choice. GI is ok I guess, but it rusts eventually and will have to be replaced. Copper last and last, and though I have heard and seen it split, dur to freezing, been ok with air so far.

  • @91rss
    @91rss Жыл бұрын

    adding an aftercooler helps a lot lots of videos on them, cousin used one from a 90's diesel pickup and installed a computer server muffin fan on a shroud he built. Night and day temperature drop, also running amzoil works

  • @ZhmiKnopa

    @ZhmiKnopa

    2 ай бұрын

    What does Amsoil do for the compressor? I’ve only used it because it lasts longer

  • @91rss

    @91rss

    2 ай бұрын

    @@ZhmiKnopa cold weather start up is the claim to fame for northern people regular oil and its easy to pop breakers as they draw too much amps

  • @christianwood7432
    @christianwood7432 Жыл бұрын

    Great info.

  • @DiligentDave1966
    @DiligentDave1966 Жыл бұрын

    In-line air regulator is a must have since most good compressors run at about 120 psi, and most tools run best at about 90 psi.

  • @JT-dx1qk

    @JT-dx1qk

    Жыл бұрын

    True that most tools say 90psi , but that is worthless for impact guns and such , my gun will take off anything at 175psi , and almost nothing at 90psi. 2 stage compressor is best

  • @DiligentDave1966

    @DiligentDave1966

    Жыл бұрын

    @@JT-dx1qk The last pneumatic impact wrench I used was a Craftsman at a job I worked at from ‘93 to ‘99, and the stuff I used it on wasn’t torqued extremely tight.

  • @mariocooldude9092

    @mariocooldude9092

    Жыл бұрын

    Yes but as you saw the pressure drop was significant so really no need for a regulator, the tool is never gonna see the at tank pressure...I only use one when I spray cars

  • @garciaautotec
    @garciaautotec6 ай бұрын

    Really nice and helpfull video, thanks for sharing

  • @richardwernst
    @richardwernst Жыл бұрын

    Interesting video. I would have started at the simplest, connect gun directly to the compressor, maybe with a short hose. Then progress through the pressure setting, and then through the filter (that was my first guess as to most restriction, but it was totally replaced in updated setup so no way to tell from this video). However, I don't really think this is important, at least to an impact gun used for short bursts, like lug nuts. It's the pressure at the gun that drives the hammer part of the gun to turn the nut, etc., not the volume of air. So running the gun with no load isn't real world testing.

  • @cbmech2563

    @cbmech2563

    Жыл бұрын

    It's a good solid indicator of what the gun will do. Torque on flywheel bolts on a Volvo is 60 ft lbs and 120 degrees turn. My nitrocat 1250k on a 3/8s hose with 175psi struggles to make 60. 1/2 inch hose and it's still going at 120 degrees.

  • @aidenjanz2690

    @aidenjanz2690

    Жыл бұрын

    Get rid of the filter and all that junk

  • @mariocooldude9092

    @mariocooldude9092

    Жыл бұрын

    ​@@aidenjanz2690 yep 👍 why he added that big ass filter makes no sense unless he's going to paint cars and then i use a little pussy one that doesn't require all that piping

  • @otisdavies1861
    @otisdavies1861 Жыл бұрын

    Great tips

  • @danielacorrea5266
    @danielacorrea5266 Жыл бұрын

    Best tire pump ever

  • @NotOnline777
    @NotOnline777 Жыл бұрын

    Nice! Thank you!

  • @836dmar
    @836dmar Жыл бұрын

    Good stuff!

  • @JohnSmith-oj3uu
    @JohnSmith-oj3uu Жыл бұрын

    Nice Job Thanks!

  • @gergemall
    @gergemall Жыл бұрын

    Great video

  • @soringabriel4062
    @soringabriel40622 жыл бұрын

    Thanks for sharing

  • @jefferybye2169
    @jefferybye21696 ай бұрын

    Thank you this has been very helpful..cause i have a upright porter cable air compressor from tractor supply and it wont run my air tools like they should be run.. Any tips or ideas for me..what should i do or replace or buy..need asap cause need to get crank bolt out of my 2016 Hyundai Santa fe sport, and dont know what gun i should get.. Either astro or thor 1894 gun

  • @meseahunt
    @meseahunt Жыл бұрын

    good info thanks

  • @rogerbranch9248
    @rogerbranch9248 Жыл бұрын

    Thanks for the video

  • @OrlBl
    @OrlBl2 жыл бұрын

    Thanks.

  • @marshallguerra1353
    @marshallguerra1353 Жыл бұрын

    Thanks for the great information!$

  • @billkrause4585
    @billkrause45853 жыл бұрын

    Thank you! Your video sure enlightened me about what's require to properly operate an impact wrenches getting the correct volume of air supply to function correctly. A very good video.

  • @jsa2145
    @jsa2145 Жыл бұрын

    Very helpfull, thanks :)

  • @zAce31
    @zAce31 Жыл бұрын

    Thanks that helped a lot

  • @jee2001
    @jee20013 ай бұрын

    Thks

  • @DannyVillagrana
    @DannyVillagrana2 жыл бұрын

    Good video

  • @dennisrocker
    @dennisrocker6 ай бұрын

    I dont who could have put all that mess on top of the first compressor. Volume is a must.

  • @kevinlopota3626
    @kevinlopota3626 Жыл бұрын

    Good video and information. But I took the easiest way out, ditched the compressor and all the B.S. involved ( like fittings and hose’s most importantly noise) and I have done what everyone else has done. Just go and by some battery operated tools.

  • @erniray1
    @erniray1 Жыл бұрын

    I have the Harbor Freight Fortress pancake compressor, 175 psi.. How would I set this up for more power?

  • @johng5295
    @johng52952 жыл бұрын

    Thanks in a million. Great content. Awesome imagination. Grade: A++💥

  • @saturnmedia1
    @saturnmedia1 Жыл бұрын

    I use 3/8 fittings from harbor freight. MUCH more airflow. Turned my regulator allllll the way up.

  • @RPB-nx7vj
    @RPB-nx7vj2 жыл бұрын

    Excellentt.

  • @rcooper5427
    @rcooper54279 ай бұрын

    Nice work, than you

  • @papergatorzfedducca7998
    @papergatorzfedducca79983 жыл бұрын

    🔥🔥🔥🔥

  • @ulrichkessler9328
    @ulrichkessler93284 ай бұрын

    Great video, i have the same problem (might be bigger) since i have the newest IR 2236 which is more powerful because has 1500ft-lbs and it requires 36CFM. I understand your goal was to remove all the bottlenecks, you put new 1/2 regulator and filter and 1/2 pipe. But every compressor has pressure switch which is the first hop, the port on the switch is 1/4 wouldn't that be still the bottleneck even if you upgraded everything downstream to 1/2? Looking at your 1/2 valve it goes to the left to your pressure switch, did you use 1/2 to 1/4 reducer?

  • @user-ly7xr4ge8f
    @user-ly7xr4ge8f11 күн бұрын

    My friend was talked into buying a 11 cfm,gas compressor but it only has 2 tube tanks totaling 9 gallons of storage, it won't work well on his big spray gun. Myl little 30 gallon, 5 hp will get better results because of the tank capacity, for spraying cars, the pulse of the compressor piston has to be buffered. You can actually see lines in,especially flat paint from having a smaller tank

  • @Floridamancan
    @Floridamancan Жыл бұрын

    I dont know why im watching this when i have electric impacts. Still good to see

  • @mikeinpa2425
    @mikeinpa24252 жыл бұрын

    Great Job showing the air pressure loss, some time you need the extra CFM to the gun to break the nuts lose. I did the same thing last year on my craftsman air compressor also, but did you change the fitting size coming out of the tank most are only 1/4 inch? I did my the locale Ace hardware, had the drill and tap to do the job. But the hose fitting I never checked since I had 3/8 hose already, going to check that this weekend for the fitting inside size. Thank You for a Great Video, hope to see more.

  • @007connecticut

    @007connecticut

    2 жыл бұрын

    I didn't want to tap larger the outlet 1/4NPT thread, so the only 1/4 NPT thread on the compressor is the very first one. I then put an adapter fittings to go male 1/4 NPT to female 3/8 NPT on the small compressor. Then 3/8 NPT piping from there. On the big compressor in the other garage I went 100% 1/2NPT on everything except that very first 1/4 NPT thread. The reason I didn't drill it larger was I was afraid I could compromise the weld and blow the fitting out. Sometimes I have bad luck so I left the original thread on the tank alone.

  • @ulrichkessler9328

    @ulrichkessler9328

    4 ай бұрын

    That what i'm saying, let's say we upgrade the traditional 1/4 lines/regulator to 1/2 but then we will still have the pressure switch which always is 1/4. Would that be still the bottleneck even if after that everything will be 1/2?@@007connecticut

  • @raymondtrotter4655
    @raymondtrotter4655 Жыл бұрын

    Thank you ever so much for this detailed information. Fixing to set up the shop this way so it all flows well. Thanks again. Trucker Ray ✝️

  • @wiedapp
    @wiedapp Жыл бұрын

    Another suggestion: You could run both compressors together, if you need more air volume. Y connectors are available at hardwarestores all over the world. T connectors I would avoid for this.

  • @immanutt4442

    @immanutt4442

    Жыл бұрын

    I concur

  • @jonnyshoestring9368

    @jonnyshoestring9368

    Жыл бұрын

    I w have 2 small compressors and sometimes it would be helpful to have more air on tap. Would both compressors have to be identical in spec I.e. hp tank capacity?

  • @wiedapp

    @wiedapp

    Жыл бұрын

    @@jonnyshoestring9368 Not really. The smaller one will work more though, if the pressure switches are dialed in the same on both. If the air tanks have a secondary air coupling, I would connect them that way. For temporary use i don't see a problem in that. But don't forget a valve in between, which should be closed while you plug the hose into the coupler. After everything is connected, you can open that valve. And to disconnect you have to close the valve first and then disconnect. If there is no valve or you forget to close it, you'll know that really fast. Nothing will be damaged, just the air of the first/last connected tank will spew out with full force. You need to couple that together with a hose, that has two male couplers, after all.

  • @jonnyshoestring9368

    @jonnyshoestring9368

    Жыл бұрын

    @@wiedapp Cheers, your input is very helpful, particularly the mention of the insertion of a shut-off valve. I give myself enough surprises 🤕😁

  • @wiedapp

    @wiedapp

    Жыл бұрын

    @@jonnyshoestring9368 One more heads up: Do absolutely check if both tanks are rated for the same pressure or dial in both compressors to the smaller value out the tanks. Air tank blow ups are everything but fun.

  • @garypostell5268
    @garypostell5268 Жыл бұрын

    The regulator should keep it at 90 psi?

  • @cornfusedatbest3980
    @cornfusedatbest3980 Жыл бұрын

    Wow, I have the same air filter. I need to find parts for this particular unit, any suggestions? I can't seem to find any info through Bridgeport. Anyway, I have the same horizontal Craftsman with 3/8" hose and haven't had any problems with lug nuts, which I do quite often (light mechanical maintenance shop) I just hit them with Deep Creep or PB Blaster ahead of time, seems to work pretty good. All in all, a great DIY video, If I have problems in the future I will definitely switch to the 1/2" hose.

  • @007connecticut

    @007connecticut

    Жыл бұрын

    1/2" hose and 3/8 fittings while keeping them short as possible will help if you need a little more cfm. The air filters on both units where bought new on Amazon just prior to making the video. Had something else on them going back 30 years. They were 1/4" fittings which I knew that was something I wanted to remove if I wanted to push the air better. I can drive 3/4 impact gun on the units too so my trailer hitch now is all done with air tools. I retired the long pipe and wrench finally. Getting too old to do all this by hand. LOL Thank you for watching.

  • @C_C_SEA
    @C_C_SEA Жыл бұрын

    💯

  • @RC-Heli835
    @RC-Heli8352 жыл бұрын

    Hey man thanks for sharing this! Do you always run a filter because you paint?

  • @007connecticut

    @007connecticut

    2 жыл бұрын

    Yes. If you don't you will see little droplets of water in your expensive paint job. Filter is good to keep the air tools drier also. They could rust up inside I guess if you don't oil them. I forget to add a few drops of oil to my tools (in the air line) so I'm guilty of that as well.

  • @joytrucker5709
    @joytrucker5709 Жыл бұрын

    I've got the popular quiet 26 gallon Kobalt from Lowes. Do you think I can upgrade it to 1/2" piping or 3/8"?

  • @007connecticut

    @007connecticut

    Жыл бұрын

    I'm sure you can. Just look at it and start to unscrew fittings. Start from the rubber hose and work towards the regulator.

  • @darrellsomers5427
    @darrellsomers5427 Жыл бұрын

    I think this might work for a painting a whole car ,but how long can you run that gun in minutes before the air compressor kicks back on thank in advance

  • @smokeeeee1682
    @smokeeeee1682 Жыл бұрын

    Hi, friend. What compressor do you recommend to use in an IG 231C? I have a 2.0 hp, 50l and 8.5 CFM, but I don't know if it will be able to move it

  • @007connecticut

    @007connecticut

    Жыл бұрын

    Get a compressor with a 20 gallon tank. If you want more you could add an auxiliary tank for not too much more money. Air guns need air volume to spin the motors. The air compressor will inflate the air tank the same, may take a little longer to do but for a home owner it will work just fine. In a later video I added an auxiliary tank of 20? Gallons so if I want a portable tank to bring some place or if I want more air tank to run more tools a little longer I can

  • @diamonddetails9445
    @diamonddetails9445 Жыл бұрын

    Genius 👍👍👍👍👍👍👍👍👍👍👍

  • @garrettgiuffre7298
    @garrettgiuffre7298 Жыл бұрын

    I bet you can answer this for me how do I get the most pressure and range from the air blower. I swear I have one that kicks the compressor on instantly and moves no air

  • @papergatorzfedducca7998
    @papergatorzfedducca79983 жыл бұрын

    New subscriber

  • @kokigephart111
    @kokigephart111 Жыл бұрын

    The compressor is not feeding the tool , the tank is. You could leave the machine stock ,get a out of date hundred pounds propane tank feed it with your machine then put high flow from the larger tank.

  • @manuelcutzal4359
    @manuelcutzal4359 Жыл бұрын

    I'M GOING TO DO IT.

  • @bradjohnson9671
    @bradjohnson9671 Жыл бұрын

    The V series fittings are the only way to go. They are backwards compatible with the M series plus they stay unlatched when no connected, just plug in the fitting. No need pull the collar back.

  • @gmacka6333
    @gmacka63337 ай бұрын

    90⁰ fittings are torture for your air flow