How-to Install Pro-Flex Gas Lines [Propane or Natural Gas]

Тәжірибелік нұсқаулар және стиль

The fittings on the Pro-Flex flexible gas pipe are pretty straightforward. Once you figure out how to get the length to a fitting figured out, that part should go smoothly - if you have the correct tubing cutter (make sure you get one of those as other methods will not work). The manufacturer recommends eight foot spacing of straps, but I went with two foot spacing as anything else cased drooping of the pipe and I din not want that.
I used 3/4" one hole Rigid Pipe strapping on the run along the top of the side of the bottom chord because the line needed to be right at the top with nothing protruding over the top. I'll be using boards up there to access the attic to blow-in insulation ay some point. Make sure to use rigid pipe straps as the EMT ones are too small 😊
Propane Links: (Also look for tagged product links in video itself);
Monster Thread Seal Tape - amzn.to/3EV24V2
CSST Tubing Cutter, 1/4-inch - 1-1/4-inch - amzn.to/3SeuiNB
amzn.to/3T3MkDq
Nylog Blue - amzn.to/3KNjtQI
DANCO Gas Test Gauge - amzn.to/3yVyPgW
🍺 If you enjoyed the video, consider buying me a beer!: www.paypal.com/cgi-bin/webscr...
We're also on Instagram: / planet_mojo
Please Share, Like, Comment, and Subscribe!
Buy me a beer: www.paypal.com/cgi-bin/webscr...
Click here to subscribe ― / @planetmojo
The Planet Mojo Website ― planetmojo.net
Thank you for watching Planet Mojo and have yourself a great day!
#ProFlex
#CSSTTubing
#GasLine

Пікірлер: 81

  • @PlanetMojo
    @PlanetMojo Жыл бұрын

    Getting all of these things done up in the rafters is the #1 priority right now. There are only five more things on that list, but one of them is build the partition wall and another is install the ceiling joists so it will take a good deal longer than five days! Here are some woodshop build links... 3M All Weather Flashing Tape - amzn.to/3ICBX4P Huber ZIP System Liquid-Flash - amzn.to/31OtCtN Seville Classics Commercial-Grade 5-Tier 60" W x 24" D - amzn.to/3qgjrXJ 5000 Lumen Temporary LED Work Light - amzn.to/3eslZfu Heavy Duty 3-Prong Wireless Remote - amzn.to/3EnPWYN Powermatic Model 60C 8-Inch 2 HP 1-Phase Jointer - amzn.to/3mvPq4M Jet Contractors Saw - amzn.to/3mAAQJs Insul-Hold - amzn.to/3evnmKq 1" Garage Door Chain Hoist - amzn.to/3rn11VF 1" 4:1 Open Garage Door Chain Hoist - amzn.to/3uldvQA 1" 3:1 Open Garage Door Chain Hoist - amzn.to/3IVxXf0 1.25" Garage Door Chain Hoist - amzn.to/32R3vmS Ambient Weather WS-2902C WiFi Smart Weather Station - amzn.to/3GzRdNp Brownell Oxpho-Blue Professional Grade Cold Blue - amzn.to/3BfKiYO Evapo-Rust - amzn.to/3gJQEq4 Xcluder Rodent Control Fill - amzn.to/3oVsH3x Great Stuff Pestblock With Smart Dispenser - amzn.to/3HfI2SG 5FT Power Twist V-Belt 1/2-Inch x 5 Feet A Type - amzn.to/3LTQQkF Aluminum 5 Slot A Type V-Shaped Pagoda Pulley 5 Step Pulley - amzn.to/33GTclJ Wixey Remote Planer Readout With Fractions - 300mm (12") - amzn.to/3scJQro TamBee Hidden Door Hinge - amzn.to/3tpstTE Yosoo Latch Lock - amzn.to/35Rh7ji Spring Load Bolt Latch - amzn.to/3hF8n2c Milwaukee 3/8" Crown Stapler (tool only)- amzn.to/3HKbtgb Milwaukee 3/8" Crown Stapler (complete)- amzn.to/3igDDoz 1000 Stainless Steel T50 Staples - amzn.to/3toLUgM MPOWER Triple Diamond Sharpening Whetstone - amzn.to/3ClrZ52 Rockwell Wood & Nail End Cut - amzn.to/3tfOQMz Pioneer Diamante Series Ductless Mini-Split (9k) - amzn.to/3twjXnb Pioneer Diamante Series Ductless Mini-Split (24k) - amzn.to/3D0Yvtw Nylog Gasket/Thread Sealant - amzn.to/3IyHCaT Mounting Bracket for Ductless Mini Split - amzn.to/3L7F8C0 Vacuum Pump and R134a Manifold Gauge Set - amzn.to/3qryKNM CopperCoat Green Wood Preservative - amzn.to/3cqxVBb

  • @JoeCarlinCA
    @JoeCarlinCA Жыл бұрын

    I've got my literal blood sweat and tears going into my kitchen remodel as well. Thanks for giving me the confidence I needed to tackle this!

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    Thanks Joe! You can do it!

  • @RobertRalphR
    @RobertRalphR Жыл бұрын

    I've always been afraid to run gas lines! Glad you're testing these!

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    I'll be testing these lines myself, but the propane company will be testing as well when they hook-up the regulator. Should be very safe 😊

  • @adenvet2830
    @adenvet2830 Жыл бұрын

    Hi Mojo, that was a great job you did up so high on the ladder at times I had my heart in my mouth, so I take my hat off to you, super job.

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    Thanks Larry! Soon I'll be working on the ceiling and the vertigo will be a factor. Hope that goes smoothly as well...

  • @ShedHomePro
    @ShedHomePro Жыл бұрын

    Heat soon! It will be nice to see that line hooked up to the heater and pumping heat!

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    Thanks Shed Homes! It's actually going to be hot today, but I will definitely need that heat soon!

  • @vince6829
    @vince68298 ай бұрын

    Thank you for sharing your knowledge.

  • @PlanetMojo

    @PlanetMojo

    8 ай бұрын

    My pleasure!

  • @ccrx6700
    @ccrx6700 Жыл бұрын

    Really nice job. Noise outside was no problem it was important work that needed get done. If you ever need some side income your plumbing skills will take you far. 💪👍😊❤️

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    Thanks Dave! My dad did furnace install/repair when I was younger, so I guess some of that rubbed off on me 😉

  • @MikeL-vu7jo
    @MikeL-vu7jo10 ай бұрын

    Ok you got me just subbed thanks !

  • @PlanetMojo

    @PlanetMojo

    10 ай бұрын

    Welcome aboard Mike!

  • @mondavou9408
    @mondavou94086 ай бұрын

    Good video. Very helpful. Maybe spend a little less time on your layout. Price update: Jan 2024 now the cutter is $38! The good news is the affiliate link still works. A lot of time they don't and I wonder if the YT'er even knows they're no longer getting commission. Big thumbs up!

  • @Andy44Andy
    @Andy44Andy8 ай бұрын

    Excellent

  • @PlanetMojo

    @PlanetMojo

    8 ай бұрын

    Thank you! Cheers!

  • @godsduality2229
    @godsduality2229 Жыл бұрын

    Never used home or pro flex. Maybe it's better now, but when that stuff first came out nothing but problems and leaks from fittings. I would go to a customer's house because they smelled gas and sure enough it was from the pro flex. We wouldn't even repair it. We would either re do the customers entire house in trac pipe, or shut down their tank until the contractor who installed it came back to fix it. There's a reason that stuff is a lot cheaper then trac pipe! Also you have to be certified to even buy trac pipe/ counter strike where has home depot will sell it to anyone. That's how people get hurt or dead But the job looks clean, not taking anything away from the craftsmanship, just the product

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    No leaks here 😊

  • @waswerebeen11644
    @waswerebeen11644 Жыл бұрын

    At 16:11 it looks like you wrapped the pipe backwards. I thought you should wrap in the tightening direction to keep the tape in place.

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    I may very well have done that. I make that mistake a fair amount of the time. 😐

  • @walterashley149
    @walterashley149 Жыл бұрын

    About to do the same thing, but under my house from back to front, with a middle T up for the stove, back and front propane access, and another T out to my shop. Let us know if any issues! Also which brand did you buy?

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    The brand is Pro-Flex. I got it on Amazon. Here are the links from that job if you need any of them: Mr. Heater 50,000 BTU Big Maxx - amzn.to/3G35gwH High Temp Silicone Boot - amzn.to/3Cy6Tld Yellow Jacket Gas Pressure Test Kit, 0-35"Wc - amzn.to/3FXUzf3 Temperature/Humidity Sensor - amzn.to/3CwMD3h Monster Thread Seal Tape - amzn.to/3EV24V2 1"x 12"x 24" Ceramic Blanket - amzn.to/3GKBy0b 1"x 24"x 32" Ceramic Blanket - amzn.to/3ilA443 ProFlex Gas Pipe (1/2" x 25 ft) - amzn.to/3gjIEis ProFlex Gas Pipe (3/4 x 25 ft) - amzn.to/3VBL0cR CSST Tubing Cutter, 1/4-inch - 1-1/4-inch - amzn.to/3SeuiNB Pro-Flex 1/2" Brass Male Fitting - amzn.to/3yF9k3l Pro-Flex 3/4" Brass Male Fitting - amzn.to/3D0gKRq Pro-Flex 3/4" Union (Coupling) - amzn.to/3ezIWRP Pro-Flex 1/2" x 1/2" x 1/2" Tee - amzn.to/3EGq2U1 Pro-Flex 3/4" x 3/4" x 3/4" Tee - amzn.to/3TcQqcI Pro-Flex 1/2in Termination Plate 1/2MIP 3/8FIP CSST Male Adapter Fitting - amzn.to/3T3MkDq Nylog Blue - amzn.to/3KNjtQI

  • @dillonlexington
    @dillonlexington Жыл бұрын

    Very nice video sir, when it comes to gas installation I only (company demanded) black Iron. So, I enjoyed your video, can you tell me though, what did you use for your 90s, I went to proflex website and all I found were male, female, manifolds and tees?!?!?!?! Also, I wish I could get my apprentices to assemble parts outside like you did, would make my job so much easier.

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    Thanks David! For most 90's you just bend the ProFlex, but if you have a real tight spot you would need to use an iron fitting and two ProFlex adapter fittings or iron into the fitting and one ProFlex fitting out. Ideally you would jus bend the ProFlex as I did. The whole object is to use very few fittings and plan the run to have gradual bends. Hope that helps 😊

  • @dillonlexington

    @dillonlexington

    Жыл бұрын

    @@PlanetMojo That makes total sense, and now that I think about it, I am saying what a dumb question...LOL, I guess I am just used to fittings everywhere due to having to run the black iron!

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    @@dillonlexington It had me baffled at first as well. They do make tees and reducer tees though 😊

  • @mikegomez5796
    @mikegomez5796 Жыл бұрын

    So I read that max psi is 5 . How can u test at 15m

  • @tallpaul8880
    @tallpaul888010 ай бұрын

    Don’t forget to bond the gas line to your electrical system ✌🏻🇺🇸

  • @joemaldonado3
    @joemaldonado3 Жыл бұрын

    remember... not all brands of parts are interchangeable! try to be consistent on this to avoid mix ups and possible problems.

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    I agree. These are all Pro-Flex parts.

  • @gabakusa
    @gabakusa4 ай бұрын

    many of those URL in your video descriptions are not working

  • @PlanetMojo

    @PlanetMojo

    4 ай бұрын

    I see that! I've added some "tagged products" in the video itself that should work.

  • @jaimedpcaus1
    @jaimedpcaus14 ай бұрын

    Hi, So, flex line can be used to do an entire area (like your doing)? Thanks

  • @PlanetMojo

    @PlanetMojo

    4 ай бұрын

    I actually used steel coming into the building and up to the rafters, then used flex to get to the heater and the location of a future heater.

  • @joeclark9042
    @joeclark9042 Жыл бұрын

    Nice job on the gas line bro but I got a question for you where did you get the gauge I would like to find me a gauge I don't know where there's any at can you help me out please I appreciate you Nice looking building also thank you

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    Thanks Joe! This one, as are almost all of them, is for a 3/4" pipe: amzn.to/3YBRAS9 if you want to connect to a 1/2" pipe you would need an adapter that can be found at any hardware store.

  • @joeclark9042

    @joeclark9042

    Жыл бұрын

    thanks bud

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    @@joeclark9042 👍😊

  • @KRich408
    @KRich4085 ай бұрын

    Unfortunately all the Links for the Tubing and fittings are dead 😢. Where I live it's hard to find stuff like this in the hardware stores. Not sure why Amazon had no active listings? It's all plastic only for direct burial not safe for indoors.

  • @PlanetMojo

    @PlanetMojo

    4 ай бұрын

    I've added "tagged links" in the video itself. Hopefully they work!

  • @gabakusa
    @gabakusa4 ай бұрын

    those connectors seems to be better than homeflex where do you buy them?

  • @PlanetMojo

    @PlanetMojo

    4 ай бұрын

    I've added "tagged links" in the video itself. Hopefully they work!

  • @user-bj4lp3fr1o
    @user-bj4lp3fr1o6 ай бұрын

    Just curious. Why not black black pipe all the way to the heaters?

  • @PlanetMojo

    @PlanetMojo

    6 ай бұрын

    Ease of install. The line is 12' up in the air, and it was a lot easier to run the Pro-Flex up there.

  • @johnpaularnett522
    @johnpaularnett522 Жыл бұрын

    Would it be recommended to run in a wall, through the attic, To out side?

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    You would have to check with code, but I believe you need steel pipe outside. I have steel coming into the building and up into the rafters, then switch to Pro-Flex up there. If it's run in a wall you would need nail guard plates on the studs so you don't nail into it later.

  • @johnpaularnett522

    @johnpaularnett522

    Жыл бұрын

    I live in the country. I am my own code inspector. Not worried about that. Just wondering if the Flex was safe to do that

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    @@johnpaularnett522 I don't think so. I would definitely put black pipe where it has the possibility of damage.

  • @Kevinw4040

    @Kevinw4040

    10 ай бұрын

    They sell poly pipe and kits with steel risers that all can be buried. The riser looks like a 2-3' elbow that connects to poly underground then the steel emerges at the ground so the poly isn't coming straight out of the ground.

  • @VIPtotheVIP
    @VIPtotheVIP9 ай бұрын

    Interesting and expensive 1:10

  • @anthonymonah7116
    @anthonymonah71162 ай бұрын

    This kind of gas plumbing would be illegal in New York City.

  • @PlanetMojo

    @PlanetMojo

    2 ай бұрын

    100% legal here.

  • @peachesonly6977
    @peachesonly6977 Жыл бұрын

    Not that anyone cares, but you put you thread tape on backwards

  • @robertc.iredale9769

    @robertc.iredale9769

    3 ай бұрын

    It doesn't do its job properly if you wrap it backwards. I'm really is a gas man.

  • @user-hd5fv6mi2u

    @user-hd5fv6mi2u

    2 ай бұрын

    @@robertc.iredale9769you are correct

  • @anthonymonah7116
    @anthonymonah71162 ай бұрын

    I saw blue tape. Tape is only used on compressed air not on C3H8 or CH4. I have my gas qualification from DOB in New York City and also Medical Gas Qualification.

  • @PlanetMojo

    @PlanetMojo

    2 ай бұрын

    The tape is "Blue Monster" PTFE Thread Seal Tape. It is rated for all natural gas, methane, propane, butane, and petroleum distillates.

  • @jamesborrelli1721
    @jamesborrelli1721 Жыл бұрын

    Not in my 90 year old house

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    Why is that?

  • @anthonymonah7116
    @anthonymonah71162 ай бұрын

    Teflon tape not allowed on natural gas neither are compression fittings.

  • @PlanetMojo

    @PlanetMojo

    2 ай бұрын

    This is propane, and yellow propane tape is used on the steel fittings. The Pro-Flex lines are 100% legal, and were installed properly.

  • @anthonymonah7116
    @anthonymonah71162 ай бұрын

    Natural gas has Sulphur that us why tape is no good. New York City has ne of the strictest plumbing codes in the U.S.,that would not fly.

  • @PlanetMojo

    @PlanetMojo

    2 ай бұрын

    It is rated for natural gas. I'm guessing they knew about Sulphur when they rated it. At any rate, it's on a propane line, and is 100% fine.

  • @bigdaddy4975
    @bigdaddy4975 Жыл бұрын

    Your putting your Teflon on the wrong direction always clockwise

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    I always forget whether its clockwise when pointing towards you or pointing away. Oh well, as long as it didn't peel-up, it will be fine.

  • @Ariel1S

    @Ariel1S

    Жыл бұрын

    @@PlanetMojo Yah, I noticed at 16:01 it was backwards. It probably won't be fine, you really should redo it. You don't have to remember the clock direction, just imagine you are screwing the fitting onto the pipe, and hold the Teflon straight while rotating the fitting in the direction of attaching it. If you do that it will be right. You can also test it after, hold your fingers over the Teflon, and rotate the fitting and see if the Teflon comes off, or if it gets tighter.

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    @@Ariel1S It will be absolutely fine if the threads go on it. The direction of wrap is just so it doesn't unravel when you are starting. If the threads go on it, it's fine.

  • @Ariel1S

    @Ariel1S

    Жыл бұрын

    @@PlanetMojo I'm sorry, but this isn't true. If the threads are backwards it tends to unwrap when you tighten it, and then it leaks. Maybe in your situation because it's very low pressure gas it can handle it, I don't know, but if you tried that with a water pipe it would leak 100% for sure. I've made this mistake occasionally, as soon as you screw the pipe you can see the Teflon start to unwind itself from the threads rather than be firmly on the threads as the pipe goes deeper into the fitting.

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    @@Ariel1S I repeat, the tape did not unwind, if it doesn't unwind, it's perfectly fine - and that would be at any pressure. If it had unwound, I would have done it over. It would not have leaked with water either as the contact is exactly the same.

  • @anthonymonah7116
    @anthonymonah71162 ай бұрын

    Not really! Because National code allows copper to be used for natural gas. New york city does not use national code, they have their own code ,the blue monster tape for gas is "yellow'' ; you used teflon tape. Sulphur breaks down the tape. California has the strictest plumbing code then its New York City.

  • @PlanetMojo

    @PlanetMojo

    2 ай бұрын

    No, they make a yellow version for places that require it . It is the exact same tape as the blue stuff. I did not use normal Teflon tape, you can see the Monster Tape on the table saw on this video at: kzread.info/dash/bejne/oH55upKTnZaXZ6w.html and here it is up close: kzread.info/dron/oYEkrBhUZGqc21ahXYdwEA.htmlcommunity?lb=Ugkx0RP1yCqrxrtls8E9bpdYahZfKVu5UQZR

  • @stevestadterman9270
    @stevestadterman9270 Жыл бұрын

    never use gaslines w o-rings,too easy to fail,countless times have torn this junk out,,only use trac pipe or gastite

  • @PlanetMojo

    @PlanetMojo

    Жыл бұрын

    That's how Pro-Flax gas lines are made.

  • @Ariel1S

    @Ariel1S

    Жыл бұрын

    @@PlanetMojo Actually from what I read the o-rings are more reliable. The metal connections of the other types are difficult to get right, they need perfect cuts and a lot more tightness to seal.

  • @anthonymonah7116
    @anthonymonah71162 ай бұрын

    I read it but no form of tape is recommended for ''gas'' because the sulphur in the gas breaks it down. ''PRO DOPE'' is better, you have to lubricate the threads not seal them. NO PERMATEX!

  • @PlanetMojo

    @PlanetMojo

    2 ай бұрын

    Wow, you really are a piece of work Tony. You see the evidence right before your eyes and continue to deny it. Technology advances, and has apparently passed you up. Stop posting your nonsense here and find someone else to harass.

  • @jaspiecat7851

    @jaspiecat7851

    29 күн бұрын

    Calm down payla

Келесі