Here I go over some of the most common problems that affect these Hayward, formerly Summit Heat pump or thermopump pool heaters. Flo (no flow) and LP (low pressure) are just some of the many problems that affect these units.

Пікірлер: 142

  • @angelikamariae
    @angelikamariae2 жыл бұрын

    Excelent video!! Thanks for sharing.

  • @rodmzn007
    @rodmzn0073 жыл бұрын

    very helpful and easy to understand ...

  • @autismhelpinformationchann8351
    @autismhelpinformationchann83513 жыл бұрын

    Very helpful information

  • @ÉricVigneault-h3k
    @ÉricVigneault-h3k13 күн бұрын

    Thanks for the video it was very informative. My question is I would like to run my Sum 4 with a variable speed water pump, but the water pressure switch is triggering a “low flow” error and won’t engage the heat. I’m thinking of replacing it by a digital programmable water pressure switch which would allow me to program a pressure range for it to close and engage the heat. Obviously it can’t be too low ‘cause I don’t it to overheat, but what do you think? Or do you have any suggestions?

  • @user-qq7pk5lz6h
    @user-qq7pk5lz6h10 ай бұрын

    super informative and helpful! perfect use of the term fuckery also!! thanks

  • @cybertech3DStudio
    @cybertech3DStudio Жыл бұрын

    Great video, my unit can't start the fan alone, I have to help it. Is it possible that the capacitor is the problem?

  • @user-bw3un7li6m
    @user-bw3un7li6m5 ай бұрын

    great video......my hay/summit xl140 is not sending signal to contractor coil.....not low on r410a, lp and hp and Flo all ohm out, no codes.....replaced board and contactor, ...when I turn it on, everything seems fine,,,,after 3 min, the flame indicators appear but does not energize the contractor coil......unit is less than 2 years old.....is there anything in the board setup I need to look at? I went through the setup as best I could...is not setup for remote etc. when I manually energize the contractor, comp runs and A/C grades react normally

  • @louishildebrand4785
    @louishildebrand4785Ай бұрын

    Thanks! very useful and complete!

  • @jean-francoisfortin710
    @jean-francoisfortin7103 жыл бұрын

    Great video, will help me look for the issue on my Summit. Any tips of what I should look at first? I get an F5 error code but it's not cold outside at all. The compressor starts but the fan doesn't?

  • @MrLuckyLaChance

    @MrLuckyLaChance

    2 жыл бұрын

    you're getting the FS because the compressor is running and the fan is not dissipating the cold out of the unit. It could be a capacitor could be the fan relay in the board or it could be the fan. Since this was from three months ago im assuming youve already made the repair or replacement

  • @marc-andreodam4034

    @marc-andreodam4034

    2 жыл бұрын

    Bonjour Jean-François, j'ai le même problème actuellement F5 ou FS ... as-tu été en mesure de résoudre ton problème ? Si oui, as-tu un conseil pour moi ? Merci

  • @dannelson7534
    @dannelson75343 жыл бұрын

    @ 9:14 in the video what psi of compressed air are you blowing into the LP switch??

  • @ronciccone7624
    @ronciccone76243 жыл бұрын

    Great Video: I have a Hayward Summit XL, entering 2 season of use. Fan runs but not getting at heat output at the inlet. Fan blowing cold air BUT I have not measure the delta T yet. Any suggestions?

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    If the fan is blowing cold air then the condenser coil must be pumping out heat to the water... These thermopump units are slow and can take a good week to get a large size pool up to temp. Especially at the beginning of the season.

  • @ronciccone7624

    @ronciccone7624

    3 жыл бұрын

    @@QuaabQueb It actually was working. I realized later that the air was to dry to facilitate a good heat exchange. As humidity increased so did heat pump efficiency. Thank you for the help. Great Channel - shoot the bird ;)

  • @jimccc9467
    @jimccc946711 ай бұрын

    I have a 3 year old just out of warranty Hayward HP21404T that has an issue. The other day it was not heating and panel read “Lo Flo”. It was shut off until today and when I turned it on it is now reading “HP”. I have read what the code means but didn’t know if you might have an idea based on age of unit. So far every Hayward component has failed and this was the last item with a problem but sadly now it’s out of warranty.

  • @tracikucherry6600
    @tracikucherry66002 жыл бұрын

    Great information video!! My unit is a lot like this one and it will start up, run for about 30 seconds and then shut off. Any idea why it’s doing this and what I can check and troubleshoot on it?

  • @mosesvani5409

    @mosesvani5409

    Жыл бұрын

    U are either overcharged on refrigeration or a restriction in the txv

  • @georgesdufresne4544

    @georgesdufresne4544

    14 күн бұрын

    maybe the input and output of water supply are inverted?

  • @andreiispas9938
    @andreiispas993828 күн бұрын

    I have a TTI heater with the exact same control panel and electric components like the summit in the video. I get the FLO code although there is flow and there's no obstruction. I changed the flow switch and is still have the FLO code. I tested the switch with a meter by turning on and off the pump and the switch it works. I even shorted the terminals where the switch goes, and I still get the alarm. Any ideas???

  • @QuaabQueb

    @QuaabQueb

    28 күн бұрын

    You shorted the terminals on the board where the flow switch connects? If so and the problem persists then there could be an issue with rhe board.

  • @madeleinedelson4109
    @madeleinedelson41092 жыл бұрын

    Amazing video! I've got a Hayward that looks nearly identical to this. Fan works fine, no error codes, but the compressor tries to kick on and it makes a loud buzzing noise for 3 seconds and then nothing. Doesn't sound like the compressor kicks on at all, so no heat. Any ideas? Could it be the compressor capacitor? why wouldn't it have any error codes? TIA

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    Yes could be exactly that. Error codes are only thrown by the sensors. The unit is just simply not turning on.

  • @madeleinedelson4109

    @madeleinedelson4109

    2 жыл бұрын

    @@QuaabQueb Not the capacitor... tested a perfect 79.7 microF... replaced it anyways and didn't solve. Noticed a loud buzz is actually coming from the contactor switch, so now I'm wondering if that's it? I ordered a $12 replacement arriving in 2 days... let's see.

  • @madeleinedelson4109

    @madeleinedelson4109

    2 жыл бұрын

    Also wasn't the contractor; replaced it, and still no luck. I'm stumped. I check the continuity of all three prongs on the compressor in all combinations... all good. when compressor tried to kick on I get a voltage drop from 246 to 200 or so, but I assumed that is normal for startup... just mine won't start up. any other ideas on what to check?

  • @stephenremillard9462

    @stephenremillard9462

    Жыл бұрын

    @@madeleinedelson4109 I have exactly the same issue. Changed capacitor, didn't do the contractor yet. Resistance check gives me around 3 ohms in all combinations. Not sure if it is normal. When compressor try to start, the breaker trips. Do you have any suggestion?

  • @neilgeens7052
    @neilgeens70522 жыл бұрын

    very good video i have a dream 12.5kw unit its has no display compressor fan running , copper pipe hot up to the heat exchange , i am gussing it may be the pcb because i have changed the display for a new device and still not working , water outlet to pool cold

  • @JP_Ross

    @JP_Ross

    11 ай бұрын

    @Instucablanator I also have the same problem here. Any clue on what it could be?

  • @moniquemiller2402
    @moniquemiller2402 Жыл бұрын

    Hi, the flexible piping on mine has leaks. Tried to put epoxy, silucone, flex tape ect...nothing holds. Can I just cut the leaking portion of piping and replace it with new one and fitings

  • @QuaabQueb

    @QuaabQueb

    Жыл бұрын

    If it is the main coil no, there is a tube that runs inside that where the refrigerant gas passed through. You cannot cut it.

  • @geolopez4375
    @geolopez43753 жыл бұрын

    Question for you my unit it's reading high pressure and stopped working. What do you suggest I check in order to fix the problem?

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    Check the service manual it lists all the possibilities for high pressure fault. In a rare case it could be a bad switch, or it can be over charged

  • @geolopez4375

    @geolopez4375

    3 жыл бұрын

    Thank you

  • @TrishZenCorner
    @TrishZenCorner2 жыл бұрын

    How do you address a code of " FS" ? For this model?

  • @josephwashington2125
    @josephwashington21253 ай бұрын

    I have a leak in the cpvc on the back side near the inlet and outlet, can i buy that type of pipe and repair it myself?

  • @QuaabQueb

    @QuaabQueb

    3 ай бұрын

    Yes if you have enough room to cut it out and glue in a new section

  • @garyhall1035
    @garyhall10352 жыл бұрын

    How do I replace the master switch on a Hayward HP50-TA? Switch works, but is very hard to move. I suspect it's probably corrosion because it doesn't appear to be weather sealed in any way. I believe the newer ones have a clear flexible cover built in.

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    Just pushes out from the back side of the panel with some retention clips on the back side of the switch it self. The contacts inside may have melted. You can use any switch the same size and current rating. You can find them at local electronics stores. Just make sure the dimensions are the same.

  • @garyhall1035

    @garyhall1035

    2 жыл бұрын

    @@QuaabQueb Thank you! I also posed the same question to Hayward on their official website over three weeks ago. Never got a reply, but today I received a new switch from Hayward with the notation, "warranty replacement." Life is good! Thanks again for your help regarding installation. I

  • @richie_waverider
    @richie_waverider2 жыл бұрын

    I've got a a unit with no error codes, the fan is spinning, the water flow is good but it is not heating the water. I noticed there is no condensation water at the base on the concrete slab it sits on. it's 5 years old. I have just opened the unit to take a look but have not diagnosed anything and I'm not educated at all in this stuff. Any suggestions before the service technician gets here in 4 days?

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    Compressor is not coming on. Check all the common issues, contactor, capacitor etc..

  • @pedrolavalable
    @pedrolavalable Жыл бұрын

    Great Video, I have to replace my sensor water temperature in my summit Pool Heater heat Pump. I buy the part SMX306000024 but i can't find where is it in the pump. Can you know where is it 6 thank you.

  • @QuaabQueb

    @QuaabQueb

    Жыл бұрын

    Just follow the wire from the controller.

  • @geolopez4375
    @geolopez43753 жыл бұрын

    How to trouble shoot high pressure reading on a summit unit?

  • @romant1703
    @romant17033 жыл бұрын

    I have an issue. I have an HP error which means waterflow is low. The system cycles off within a few second of cycling on. The flow is fine, The pressure switch is fine but I ran out of things to look for. I got taken last year on a repair and would really like to do what I can prior to calling a tech. I've been looking for a water flow sensor in the unit but can not find it. It is the same system as the one in this video. It is a salt water pool. Any recommendations would be appreciated. Thanks

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    Could be a band switch, or an issue with the refrigerant charge. Flow issues I have only seen with variable speed pumps when they are set to run at low RPM.

  • @romant1703

    @romant1703

    3 жыл бұрын

    @@QuaabQueb You mean the water pressure switch? I checked it and even changed it out and it still does it. Is there a flow switch anywhere in that unit? I know there's one in the piping for the salt water.

  • @mosesvani5409

    @mosesvani5409

    Жыл бұрын

    U have a restriction in the txv

  • @4hernan
    @4hernan2 жыл бұрын

    Any idea how to fix an LP3 error

  • @ceciliamiske8427
    @ceciliamiske84272 жыл бұрын

    The clear tube running from the pressure flow switch came off the end that connects to the pipe in the back…looks like the piece that was connected to the pipe broke off….how would I repair that? It looks like something was kinda just screwed into the pipe with a nipple like thing coming off the top for the tub to slid over….does that sound right?

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    Yes it's a small barbed end You would need to get a new pressure switch assembly. The hose is also held on by a crimp clamp.

  • @St4r_girly

    @St4r_girly

    2 жыл бұрын

    So this happened to me as well yesterday! How do I get to that back pipe? And where can I find the pressure kit assembly I’ve looked all over the internet. I have a Hayward summit xl

  • @ceciliamiske8427

    @ceciliamiske8427

    2 жыл бұрын

    @@St4r_girly so I was actually able to find everything I needed at Lowes….my switch was still good so I just got the same size clear tubing from plumbing section in Lowes and found a brass barbed fitting in the plumbing section and used epoxy to kinda glue it back into that pipe…drilled out the hole so the brass fitting would push down into it….connected other end to pressure switch fitting….BAM the heater kicked right on!!! Hope this helps ya!! I took the top off where the fan is…got to it that way….definitely a stretch but easier to see everything…

  • @mariorodriguez653
    @mariorodriguez6533 жыл бұрын

    I have a Hayward HP50HA and it’s tripping my breaker open when in Auto mode (not during Heat/Cold). Have an idea of what it could be?

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    There is a short somewhere

  • @billneurohr2904

    @billneurohr2904

    2 жыл бұрын

    @@QuaabQueb me too. 20amp breaker blows after a few min run time. Did you find cause?

  • @stephenremillard9462

    @stephenremillard9462

    Жыл бұрын

    @@QuaabQueb What should be the resistance between each combinations (common, run, start) of a good compressor? I am getting about 3 ohms for all, is it normal. Mine too tripps the breaker :-(

  • @waynelynds4355
    @waynelynds4355 Жыл бұрын

    I have no power to the front control board when I turned it on power is coming in but nothing on the control board

  • @gbanks
    @gbanks3 жыл бұрын

    @Chargero wonder if you can help me trouble shoot? My heat pump will not turn on at all. I have power. My display will not turn on and if I press the bypass coil to give power directly to compressor and fan nothing happens. I can see that power makes it across when I press the coil in.

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    Might be bad contactor.

  • @gbanks

    @gbanks

    3 жыл бұрын

    @@QuaabQueb You think so even if I get a reading once I press the bypass coil in? Wouldn't that mean it is getting power? Although it does not turn on the compressor or fan.

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    @@gbanks The contactor is the only thing between the mains lines coming in to the unit and the compressor/fan. The Control circuits are powered by a transformer that drops 120V to 24V

  • @gbanks

    @gbanks

    3 жыл бұрын

    @@QuaabQueb Replaced the contactor. Still no display and compressor/fan not turning on. Thinking to replace the transformer next.

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    @@gbanks Test it. Check voltage output on the secondary. Follow the terminals from the transformer to the board. But when you depress the contactor it should kick on the fan/compressor. You are effectively bypassing the control circuit that energizes the contactor coil. Are your fan/compressor capacitors good? I have seen power surges blow these units. Typically a ruptured capacitor is a sign.

  • @holdenhenry6789
    @holdenhenry6789Күн бұрын

    I have the same heater and it will shut off after around 3 minutes and it trips the breaker on my panel. I took it apart and nothing looked bad, can you provide any help? Thanks

  • @QuaabQueb

    @QuaabQueb

    Күн бұрын

    @@holdenhenry6789 If it's setting the breaker then something is shorting. I would recommend using a clamp style meter to monitor the current and see if and where it's rising. You say it "runs" for 3 minutes. Is the compressor on for 3 minutes? Or is it setting the breaker as soon as the compressor kicks on.

  • @holdenhenry6789

    @holdenhenry6789

    Күн бұрын

    @@QuaabQueb I think it's kicking out when the compressor kicks in, because the fan and screen are operating fine but I'm not positive when the compressor is supposed to kick in. I appreciate the help, I have an old multi meter, maybe I will dust it off to see if there's a short.

  • @QuaabQueb

    @QuaabQueb

    Күн бұрын

    @@holdenhenry6789 You would need a clamp style multimeter that you can clamp on the wires. If it's setting the breaker as soon as the compressor kicks on then it could be a seized compressor. It's possible it could also be a defective breaker

  • @alexandteresalandestoy234
    @alexandteresalandestoy2342 жыл бұрын

    Great video! Thought the effing bird was outside my window for a second. Is the flow switch tube supposed to have water flowing through it ? I see air bubbles and a bit of water in mine and am wondering if Its air locked and simply needs the air bled out of tube Thanks again for the great video

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    Flowing, no I don't believe so. If there is pressure in the system it should activate the switch

  • @alexandteresalandestoy234

    @alexandteresalandestoy234

    2 жыл бұрын

    @@QuaabQueb thank you. I’m going to pull the tube off and drain it. Thank you!

  • @caragannon2648
    @caragannon26482 жыл бұрын

    hey, so I have a Hayward heat pump. The fan runs., but when the condenser kicks on runs for about 30 seconds then bogs out. and then the lp come code comes on, tries all over again. Any ideas on what it could be? I changed the capacitor already.

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    Yes that is the low pressure error code. The causes are listed in the manual. Usually it is because it is too cold outside.

  • @caragannon2648

    @caragannon2648

    2 жыл бұрын

    @@QuaabQueb yeah i looked at them but too cold isn't a problem because I live in Florida . i am thinking that I might have to bite the bullet and get a new heater

  • @caragannon2648

    @caragannon2648

    2 жыл бұрын

    thank you

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    @@caragannon2648 page 10: hayward-pool-assets.com/assets/documents/pools/pdf/troubleshooting-guides/HeatPump-troubleshooting-guide.pdf

  • @user-jn8hx6re4c
    @user-jn8hx6re4c Жыл бұрын

    So I had the white pvc pipe in the back of this unit explode, after the company opening the pool for me didn't open he valves and ran the pump causing a buildup of pressure. Is there a way to lift the copper surround on this unit to be able to get to the pvc pipe in the back and replace them? I'll pay for guidance not looking to get something free out of you, I know it's your job.

  • @danielherron3
    @danielherron3Ай бұрын

    Hi, I have a Summit_XL_Hayward, when I turn on the breaker the fan works, but the screen doesn't show anything and the water doesn't go warm. Does someone know what could be?

  • @QuaabQueb

    @QuaabQueb

    Ай бұрын

    The power supply to the control board. It could also be the display is not working or the board is defective.

  • @Bottlejack1
    @Bottlejack13 жыл бұрын

    I have a new just installed raypack. Never run. Trips on high pressure. I checked the water flow. Well above 40gpm. Coil temp drops on start up gets to about 35f. Then compressor shuts down. Ambient temp is 53-55. Water temp 49f. Kinda head scratching my head. I have no bypasses. Possible to much refrigerant from factory? Trips in less the 2min

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    Yes that is possible. Geographic elevation is also a factor.

  • @Bottlejack1

    @Bottlejack1

    3 жыл бұрын

    @@QuaabQueb 597ft. About the same as Detroit. Any other possibilities?

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    @@Bottlejack1 I'm not an hvac technician so my experience is limited with with refrigeration. If the unit is brand new something is likely not hooked up right. Try and find the manual for your particular model of unit. All of the operating specifications will be listed and you can begin to troubleshoot from there.

  • @Bottlejack1

    @Bottlejack1

    3 жыл бұрын

    @@QuaabQueb thanks. I dig into it a bit more.

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    @@Bottlejack1 if you do end up calling an hvac guy to check it out make certain they are well versed with pool heaters.

  • @timdogsprincess
    @timdogsprincess2 жыл бұрын

    I have a Hayward electric heat pump. It was tripping the breaker once in a while I would reset the breaker and it would heat and work with no problem. It did that a couple times and now the fan won't come on. I replaced the fan and the capisitors and it still won't come on any idea what it could be.

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    Something is shorting or pulling toomuch current.

  • @timdogsprincess

    @timdogsprincess

    2 жыл бұрын

    @@QuaabQueb any idea where to start, I pushed coil contactor in and the compressor gets super hot really quick. I have checked all wiring and it looks good. I have power going to the fan.

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    @@timdogsprincess check the compressor windings with a multimeter. I have seen the pins blow out so look at them carefully to see if thru look burnt or damaged. Always be careful poking around in there as the capacitors can hold a charge for some time.

  • @timdogsprincess

    @timdogsprincess

    2 жыл бұрын

    @@QuaabQueb will do I have checked the ones at the capacitors and the contact switch, they look good. I will check the wire connector right at the compressor.

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    @@timdogsprincess yes look up how to test compressor winding resistance. You can also use a clamp type multimeter to check the current draw of the unit. If it is pulling abnormally high current you know there is a problem. Remember the circuit breaker is an overcurrent protection device. It's function is to open the circuit if something is abnormal. Ex.: A direct short back to the source (not ground!!) , or an overloaded piece of equipment.

  • @rosarioachi4816
    @rosarioachi4816 Жыл бұрын

    Quanto gas R410 prende una macchina come questa?

  • @stevegingras1625
    @stevegingras16252 жыл бұрын

    Today, the same unit gave me a dsd ou d5d code. The display light up and shows the water temp for 5 seconds than I get this code and nothing works. I can't find anything related to this error code anywhere. Any ideas ? Thanks

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    The error codes and their meanings are listed in the manual if I remember correctly, did you check there? You can google the model number and should be able to find the manual.

  • @stevegingras1625

    @stevegingras1625

    2 жыл бұрын

    @@QuaabQueb Thank you ! No, it's not in the manual. But I finally found the info. It means "defrost sensor defect". I ordered this part and I am going to replace it. We will see ...

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    @@stevegingras1625 interesting where did you find the code meaning?

  • @stevegingras1625

    @stevegingras1625

    2 жыл бұрын

    @@QuaabQueb I search so hard that I can't find back from where. It was in a forum I think. I already got the part yesterday. Will try to install shortly. I will tell you if it solved the issue

  • @chizzlemo3094
    @chizzlemo30943 жыл бұрын

    sniffer: $23.... replace the system $2,600, replace the whole unit $5,000. Funny how all repair guys are reluctant to repair it. Do it yourself.

  • @user-ip7gx1yu1l
    @user-ip7gx1yu1l Жыл бұрын

    My pump shows F5 what do i do

  • @tonyblanco4631
    @tonyblanco46312 ай бұрын

    Mine shows LP but that means

  • @moebee3882
    @moebee38822 жыл бұрын

    trying hard not to smash this thing but anyways. New capacitor, new contactor ..not starting up. Shows the pool light and current temp of water but...le sigh nothing happening. The ole' push on the contactor with a screwdriver turns it on though...maybe I'll just keep the position. I'll try the water pressure switch trick tomorrow. What is that black part called that I'll be hitting up the electronic store for please and thank you.

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    Try and jump the water pressure switch to see if that is the problem, if not maybe the contactor is not getting power

  • @moebee3882

    @moebee3882

    2 жыл бұрын

    @@QuaabQueb tried that today too..nada.

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    @@moebee3882 check high and low pressure switches?

  • @moebee3882

    @moebee3882

    Жыл бұрын

    @@QuaabQueb if I'm doing this right, the LP has continuity but the HP shows a big fat OL.

  • @QuaabQueb

    @QuaabQueb

    Жыл бұрын

    @@moebee3882 I believe it should also show continuity

  • @jaredmallett6091
    @jaredmallett60912 жыл бұрын

    I have this same shitbox and after a dozen uses the low pressure switch died. One year old unit. I had an AC company come out and put gauges on it, full charged. Bought another LP switch that lasted 2 days. Had to hotwire it to run, which it did fine for 2-3 uses. Ice built up on the last use. Now, no heat output. I want to punt this pile of shit through the goalposts of life. Nobody services these in my area. I guess I need to buy gauges now.

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    They are pretty good units compared to a lot of the crap on the market. It sounds like you may have other issues. I would start by checking the charge once again and make sure it is within manufacturer specs. It may be over charged. If you have a residential HVAC guy who is not familiar with pool heaters specifically he may have fucked it up. If you keep popping LP switches that hints me that the unit may be over charged. Good luck...

  • @Freedomyota
    @Freedomyota2 жыл бұрын

    I need the fan motor, blade and the top panel from this unit - wanna sell it?

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    I had scraped the unit. Parts are pretty standard. Check ebay.

  • @Freedomyota

    @Freedomyota

    2 жыл бұрын

    @@QuaabQueb thanks for the reply - already did - the top panel is on global back order. Have had one on order for the last 3 months. Good video though!

  • @JasonJohnson-ke2pr
    @JasonJohnson-ke2pr3 жыл бұрын

    Haha...control box with all the " fuckery "

  • @chrismason193
    @chrismason1933 жыл бұрын

    How to I replace cracked pvc on the back side?

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    The inlet connector or the coil ?

  • @andrewmac8097

    @andrewmac8097

    2 жыл бұрын

    @@QuaabQueb inlet connector y pipe one cracked hard to get access to

  • @andrewmac8097

    @andrewmac8097

    2 жыл бұрын

    How to get access to the back portion does the bottom disconnect

  • @2MUCHPWR

    @2MUCHPWR

    2 жыл бұрын

    @@QuaabQueb same question. the pvc pipe is leaking. the side opposite from where the electrical box is... the white PVC on the bottom horizontal to ground. its got a split and i don't know how to get access over there.

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    @@2MUCHPWR sounds like freeze damage.

  • @astroboy3791
    @astroboy37913 ай бұрын

    I have LP error code

  • @QuaabQueb

    @QuaabQueb

    3 ай бұрын

    LP is low pressure I believe. You can look it up in the manual

  • @joenwc
    @joenwc3 жыл бұрын

    Apparently youtube needs a rating system, you made it less than a minute without using the F word. There are still people in this world that are bothered by this, I am one of them. Too bad for me I guess, but I won't watch farther.

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    Go find another video then

  • @nateatonu

    @nateatonu

    3 жыл бұрын

    BOOOOOOOOOOOOOOOOOOOOOOOOOOOOO

  • @deank2191

    @deank2191

    2 жыл бұрын

    ❄️❄️❄️

  • @TrishZenCorner
    @TrishZenCorner3 жыл бұрын

    How do i replace a hayward pool heater fan motor part #303088001 ?

  • @QuaabQueb

    @QuaabQueb

    3 жыл бұрын

    Top grille comes off. Simply remove the screws around the sides. Trace the wires back in to the cabinet and disconnect them. Take pictures before unplugging anything so you can see how it goes back together.

  • @TrishZenCorner

    @TrishZenCorner

    3 жыл бұрын

    Thankkkk youuuuuu🙌🙌🙌🙌👍👍👍👍 @@QuaabQueb

  • @TrishZenCorner

    @TrishZenCorner

    2 жыл бұрын

    @@QuaabQueb I did it you are amazing thank you!!!!! Now time to figure out what the heck is a FS error I'm golden lol 😆 have a great one thank you for the help again !

  • @QuaabQueb

    @QuaabQueb

    2 жыл бұрын

    @@TrishZenCorner Google the manual and go to the error codes list, all the error codes and their explanations are listed as well as a brief troubleshooting tip

Келесі