How to Convert 13A To 15A Socket & Plug | Replace UK 3 Pin 13 Amp to 15 Amp Socket Plug

Тәжірибелік нұсқаулар және стиль

Tutorial how to replace 13A to 15A plug and socket.
Caution:
AVOID FROM ELECTRIC SHOCK!!!
Call for Assistance or Electrician for help if you have doubts in electricity connection further.
#plug
#13Amp
#ukplug
The 15A/16A plug is most commonly used in South Africa and in the UK for stage lighting. As there are 3 types of round pin plug, it is important to check your plug before ordering. The rating should be detailed on the plug itself. If you are unsure, measure the distance between the pins. This adaptor is only compatible with the 15A/16A plug (right). For the smaller 5A/6A used in the UK for table lamps and also most commonly in India.
Specification:
*Please note that the maximum current of any appliances connected must not exceed 13A, as the unit is protected by the 13A fuse in the plug.
*Tough Permaplug UK 13A plug with 13A fuse.
*High quality Permaplug 15A round pin socket.
*0.3m of 1.5mm rubber cable for high current applications.
*The industrial specification H07RN-F rubber cable is specifically manufactured for harsh environments.
*PAT tested.
What countries use a type M plug?
The plug is used in 16 countries. Please note that some countries may also use other types of plugs.
Bhutan, Botswana, India, Israel, Kuwait, Lesotho, Macau, Malaysia, Mozambique, Namibia, Nepal, Pakistan, Singapore, South Africa, Sri Lanka, Swaziland, UK (for stage lighting only).
Top Search:
How to replace 13A 3 Pin Plug
How to replace 13A Socket
How to convert 15A plug
How to convert 13A plug
Cara tukar soket 13A plug
Cara tukar plug 13A
Cara tukar plug 15A
Cata tukar soket 15A

Пікірлер: 55

  • @ezy2cook
    @ezy2cook2 жыл бұрын

    Thanks for the tutorial

  • @TonaziTube

    @TonaziTube

    2 жыл бұрын

    Welcome Sir

  • @nhstudio508
    @nhstudio5082 жыл бұрын

    Thanks for the guidance

  • @TonaziTube

    @TonaziTube

    2 жыл бұрын

    Welcome

  • @reen964
    @reen964 Жыл бұрын

    Hi there … Thank you for the tutorial! Clear step by step. Question : If I change from 13AMP to 15AMP, will it not overload the fuse box ? Just 1 socket/plug to change for oven use

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    Hi friend!Thank for watching.If your main fuse box use over 15Amp,it should be not a problem to change.

  • @reen964

    @reen964

    Жыл бұрын

    @@TonaziTube How do I check the max load of my fuse box ? Is it stated anywhere on the box ?

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    You need to check the MCB specification in the box.Believe have a few pieces in the fuse box.Need to find which MCB connect to the socket supply place(for oven use). MCB Current and Curve Rating: , Example if mentioned C20 . The numeral part indicates rating of MCB in Ampere. In the given example it is 20A. MCB rating is very important and be very precise about it.

  • @reen964

    @reen964

    Жыл бұрын

    @@TonaziTube thank you so so much for your replies. Appreciate your help 💜

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    Welcome 🤗! Thanks for watching and pls support by subscribing this channel

  • @madamhousewife4713
    @madamhousewife47138 ай бұрын

    Hi, mine iron steam press using 15A plug top. Can I replace 13A wall socket to 15A directly? Can existing cable hold the load?

  • @TonaziTube

    @TonaziTube

    8 ай бұрын

    You need to check wire pin gauge first.If gauge over 14 size,there should not be a problem to change to 15A.

  • @toqq3395
    @toqq339511 ай бұрын

    Hi, if my current wall socket is a round 3 pin 15A. Will it be okay if I change the socket to rectangle 3 pin 13A to match my fridge?

  • @TonaziTube

    @TonaziTube

    11 ай бұрын

    No problem if use 13A from 15A designated.

  • @TheDingfish
    @TheDingfish Жыл бұрын

    Hi, thanks for tutorial. How about if my wall outlet is already 15amp 3 round pin, I need to use power tools with 13amp plug, I don't want to change the plug head to 15amp. Can I just use an adapter to plug in my 13amp items? They are around 1200-1500watt and will only use one at a time. Is it safe? The amperage use of the tool is lower than wall outlet should be ok right?

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    You’re most welcome and thanks for watching.For your cases,it should be no problem if using adapter for 13 Amp and only use one at a time.

  • @TheDingfish

    @TheDingfish

    Жыл бұрын

    @@TonaziTube thanks! If I want to test the power on the 15amp wall outlet can I also just use the test pen(same type as your video) in the live (bottom right)?

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    It was my pleasure! Pls be careful when handling with the electricity ⚡️.Beside test pen ,you may also measure the output voltage from wall outlet by using multimeter.

  • @HM13.
    @HM13. Жыл бұрын

    Can i use a Chinese brand10A water dispenser, change it to a UK plug 13A fused socket?

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    By assuming that the 13A plug you’re referring to is British, I’m guessing that the 10A connector is using 240V. In that case, yes, you could technically change the plug without any problems - just put a 10A fuse in the plug to be safe. A UK outlet was historically protected by a 13A fuse, which is why it is necessary to protect your appliance with the correct type of fuse at the plug. Of course, using electrical appliances in countries they’re not approved or certified in is another kettle of fish....

  • @one688easy
    @one688easy Жыл бұрын

    my exisitng wiring on aircon is 15A type and using 15A socket n plug , but for some reason, can i change JUST the plug and socket to 13A type?

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    Need to check current (Ampere) requirement on your Aircond usage.If use more than 13Amp,not recommended to change.

  • @mikethompson7296
    @mikethompson7296 Жыл бұрын

    The cable in the patress box looks like 1mm or 1.5mm flex which is absolutely not enough for a 15a circuit.

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    It was 14 Gauge size

  • @jiaqinglim5084
    @jiaqinglim5084 Жыл бұрын

    If I change to a 15A and socket plug, do I need to change the thickness of my extension wire to thicker wire??

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    You may check the wire thickness.If 2.5mm ,it can support until 22A.

  • @one688easy

    @one688easy

    Жыл бұрын

    @@TonaziTube may i how do know 2.5mm support till 22A ?

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    A 2.5mm cable is capable of supplying around 23-25 amps depending on the method of installation, so is fine, safe and compliant on a 20amp circuit breaker.

  • @prithal.1068
    @prithal.1068 Жыл бұрын

    Hi , how can i change a 220v 10A china made oven plug to malaysia 250V 13A? Just change can ?

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    Hi! You can change it.Just replace the plug.

  • @prithal.1068

    @prithal.1068

    Жыл бұрын

    @@TonaziTube thanks for your reply but the difference in 10A and 13A Fuse doesn't matter ?

  • @prithal.1068

    @prithal.1068

    Жыл бұрын

    @@TonaziTube need to change the fuse?

  • @Rivenworld
    @Rivenworld8 ай бұрын

    You need to make sure the cable rating is right before putting a 15amp socket in place of a 13 amp one.

  • @TonaziTube

    @TonaziTube

    8 ай бұрын

    14 AWG copper wire is the most common choice for a 15-Amp circuit. 14 AWG copper wire is ranked 20 Amps at 75°C. If you choose to use aluminum wire, the correct size for a 15 Amp breaker is 12 AWG. However, copper cables are a better choice for 15 Amp breakers due to safety and efficiency concerns

  • @dannydao1660
    @dannydao1660 Жыл бұрын

    Dude, have you insured sufficient fire insurance before you made such alteration?

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    Done

  • @one688easy
    @one688easy Жыл бұрын

    AIRCON must use 15A socket right?

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    Yes ! Recommend for 15A

  • @sadhanandss
    @sadhanandss Жыл бұрын

    hey buddy where can i buy that 15amp UK wall socket

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    I'm buying at electrical supply shop.You may search Electrical or Hardware shop nearby at your country.

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    You may buy at online shop also. shp.ee/mxdddt6

  • @sadhanandss

    @sadhanandss

    Жыл бұрын

    Thanks buddy

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    Welcome Friend!

  • @celehsaf3619
    @celehsaf3619 Жыл бұрын

    Can you replace a 13 A to 20 A in a plug?

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    Need to check wire or cable use type?Support to 20A or not.

  • @celehsaf3619

    @celehsaf3619

    Жыл бұрын

    @@TonaziTube how can we chat one one one? I have so many questions

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    We can chat here,no problem

  • @celehsaf3619

    @celehsaf3619

    Жыл бұрын

    My circuit breaker/ industrial socket is rated 32 A 220 volts. Can it power a 13 A 220 volts appliance or it it can burn?

  • @TonaziTube

    @TonaziTube

    Жыл бұрын

    The number “32” means that the Circuit breaker will handle up to 32 amps before tripping. The curve determines how long the circuit breaker will hold before tripping at various over-current levels. If using 13A 220V,it should be no problem.

  • @user-bm5hf1ph4n
    @user-bm5hf1ph4n3 ай бұрын

    this is terrifying

  • @TonaziTube

    @TonaziTube

    3 ай бұрын

    Sorry for an issue

  • @user-bm5hf1ph4n

    @user-bm5hf1ph4n

    3 ай бұрын

    @@TonaziTube you screwed down onto your cables insulation which is a main cause for fires at sockets you should remove some insulation and twist the wire until it will not twist anymore then tighten onto that exposed cable and you will have a safe socket though the other end of that wire may also need to be reinstalled

  • @TonaziTube

    @TonaziTube

    3 ай бұрын

    @user-bm5hf1ph4n Thanks for advise

Келесі