No video

How To Check Ac Sensor Working Or Not | Split Ac Sensor Testing Kaise Kare

Where are AC sensors?
The AC sensor on your thermostat is located near the evaporator coils. Indoor air moving toward the return vents passes by the sensor and coils. In turn, the sensor reads the temperature and checks if it matches what you've set on the thermostat
How do I know if my AC sensor is working?
Signs of a Faulty Sensor You might notice that your air conditioner doesn't turn off when the house reaches the set temperature if you have a faulty sensor, Your AC will just continue to blow cold air. The temperature may even become uncomfortably cold
What if AC sensor is not working?
Faulty thermostat - If your air conditioning unit's sensor isn't working correctly, it could be because of a faulty thermostat problem. When this happens, the sensor may usually cycle intermittently in an on and off manner during proper activation periods
How do you change an AC sensor?
Step 1: Locate the evaporator sensor
Step 1: Disconnect the negative battery cable
Step 2: Remove the sensor electrical connector
Step 3: Remove the sensor
Step 1: Install the new evaporator temperature sensor
Step 2: Reinstall the electrical connector
Step 3: Reinstall the negative battery cable
How do I fix my AC remote sensor?
If you've ruled out that the remote is faulty reset the system by turning it off at the main power, and leaving it off for about 30 minutes. If the problem persists once you have turned the power on again, we recommend you book a service so a technician can run a diagnostic check of the system
#AC_sensor_is_not_working #air_conditioner #split_ac

Пікірлер: 62

  • @shalenprasad1342
    @shalenprasad1342 Жыл бұрын

    Very nice video sir thanks 👍

  • @kabirkhan3496
    @kabirkhan34962 ай бұрын

    Apka dekhana oar samjana muje accha laga. Thank you.

  • @Afrozibrar19
    @Afrozibrar19 Жыл бұрын

    Very nice video 👏👏👏

  • @ashoksolanki7631
    @ashoksolanki763111 ай бұрын

    Very good teaching sr,

  • @safikul98w
    @safikul98w2 жыл бұрын

    Sir , one video is discuss all causes not cooling ac or refrigerator pleased sir

  • @Amarjeet11tec
    @Amarjeet11tec9 ай бұрын

    Good explain sir ji ♥️♥️

  • @AMRESH11TECH

    @AMRESH11TECH

    9 ай бұрын

    Thanks

  • @amarjeetpateljeetupatel5948
    @amarjeetpateljeetupatel59482 жыл бұрын

    Sir claimp meter ka pura jaankari kya puri video banao please sir aap ki video latest rahti hai

  • @AMRESH11TECH

    @AMRESH11TECH

    2 жыл бұрын

    Ok

  • @namdevfilms5077
    @namdevfilms50775 ай бұрын

    Good 👍

  • @user-xk7pm5zy7k
    @user-xk7pm5zy7k11 ай бұрын

    Sir good

  • @user-os9rz2zn9p
    @user-os9rz2zn9p2 жыл бұрын

    Please tel me about hot water heat pump also

  • @user-xk7pm5zy7k
    @user-xk7pm5zy7k11 ай бұрын

    Nice

  • @mohammedfasiuddin7225
    @mohammedfasiuddin72254 ай бұрын

    Samsung digital inverter split Ac unit me E1 01 error code aa raha hai...indoor pcb me 3 sensor's hai... Usme room temperature sensor me reading 1 show kar rahi.. Aur evoporator coil me bhi reading 1 show kar rahi... 1 aur evoporator coil sensor hai usme 1543 reading show ho rahi ... To isme kaunsa sensor sahi or acha hai taake jo defective sensor use change kar saku... Reply urgent...

  • @prabavathichandran-pk6rd
    @prabavathichandran-pk6rd4 ай бұрын

    Coil sensor or room sensor dono same kaam kartah hai or alag alag karthai

  • @BrijeshYadav-xt4ny
    @BrijeshYadav-xt4ny2 жыл бұрын

    Thanks 👍 sir

  • @AMRESH11TECH

    @AMRESH11TECH

    2 жыл бұрын

    Welcome

  • @guridhillon8955
    @guridhillon89552 жыл бұрын

    Sir ji mera 1tone o general spilt ac 1connector room and coil sensor laga hoya ha dona sensor kilo same hoga

  • @kabirkhan3496
    @kabirkhan34962 ай бұрын

    Indoor mai ice ki problem bataoge

  • @renjuramachandranpillai9824
    @renjuramachandranpillai9824 Жыл бұрын

    Exltent video

  • @AMRESH11TECH

    @AMRESH11TECH

    Жыл бұрын

    Thanks bro

  • @cocoali001
    @cocoali001Ай бұрын

    Sar aap inverter ka Bata rahe hain ya non inverter ka Bata rahe hain ❤️😕

  • @RohitKumar-vo4sc

    @RohitKumar-vo4sc

    28 күн бұрын

    Bhai inverter or non inverter dodo ke ase hi chake krte hai

  • @loveindia11211
    @loveindia112112 жыл бұрын

    Amrish bhai, ambian temprecher sensor bhi compresser ko trip karata hai kya

  • @AMRESH11TECH

    @AMRESH11TECH

    2 жыл бұрын

    Ha outdoor supply cut Karta hai

  • @Sona-vt4ry

    @Sona-vt4ry

    Жыл бұрын

    Yes Ambient temprature is trip compressor, only in one condition when ambient temprature is less than set temperature.

  • @echia324
    @echia324 Жыл бұрын

    Sir inveter ac sensor pe details me video banaye please

  • @AMRESH11TECH

    @AMRESH11TECH

    Жыл бұрын

    Ok brother

  • @kritikasingh9524
    @kritikasingh95242 ай бұрын

    Room temperature sensor temperature ko increase kar raha always 31+ hi rahta 35 tak ho jata hai, jabki hum 23-25 tak set kar chala rahe hai

  • @VirendraKumar-ox3ct
    @VirendraKumar-ox3ct Жыл бұрын

    Coil sanser ka man kaam Kaya ha

  • @danishali4550
    @danishali455011 ай бұрын

    Inverter AC outdoor PCB ka bdr Tod de to AC kaam karega ya nahi

  • @hariomkumar6366
    @hariomkumar636610 ай бұрын

    Just waiting time.

  • @nakulraut2288
    @nakulraut22882 жыл бұрын

    What is the both indoor temperature sensor price?

  • @munimmistri4947
    @munimmistri4947 Жыл бұрын

    Sir room or pipe sensor dono hi comparsussr ko of karte hai to dono sensor lagane jururet ko hoti hai 1hi sensor kabhi thaa please samjha do

  • @AfrozKhan-uj9dw
    @AfrozKhan-uj9dw2 жыл бұрын

    Sir kya hum R22 gas wale compressor ki jagha R32 wala compressor laga sakte he ki nai

  • @AMRESH11TECH

    @AMRESH11TECH

    2 жыл бұрын

    Ha

  • @1991junaid1991
    @1991junaid1991 Жыл бұрын

    Mera 1.5 ton hitachi dc inverter split ac h 32 temperature set krne par bhi lagatar 6 ampere load aa rha h or room bahut hi jyada cool ho rha h Company wale ne dono pcb aur Room censor bhi change kr diya h fir bhi koi fayda ni hua Sir meri preshani door kariye

  • @electromix2112
    @electromix21122 ай бұрын

    Sir wire ko muh se katna hai ya tool se 😅😅😅😅

  • @harinderkumar5580
    @harinderkumar5580 Жыл бұрын

    Sir if one sensor is working other not working, compressor will cut or not. Why two sensors are required

  • @sandeepsaw6825
    @sandeepsaw68252 жыл бұрын

    Sir jo apne video banyii thi thermostat k regarding Sir meraa condition kuch orr hai mre wale godrej fridge mai jydaa pahad barf nhii jamtii hai lekin 5 ghnte fridge band krne k baad cooling krtaa hai Kyaa mujhe thermostat change krnaa hai yaa phrr gas ????

  • @AMRESH11TECH

    @AMRESH11TECH

    2 жыл бұрын

    Uska heater kharab hoga

  • @user-il7rd4tq2j
    @user-il7rd4tq2j Жыл бұрын

    Outdoor side ka compressar aur fan dono sath main band aur chalu kyo ho raha h

  • @samuddinansari3315
    @samuddinansari3315 Жыл бұрын

    Sar.Aap.se.me.bat.karna.chahtahu

  • @AMRESH11TECH

    @AMRESH11TECH

    Жыл бұрын

    Ok

  • @ganeshvarma1227
    @ganeshvarma12272 жыл бұрын

    Thik hai sir

  • @AMRESH11TECH

    @AMRESH11TECH

    2 жыл бұрын

    Ok

  • @aneesabbasi486
    @aneesabbasi4862 жыл бұрын

    Aap kah se ho sir

  • @AMRESH11TECH

    @AMRESH11TECH

    2 жыл бұрын

    Up ( gkp )

  • @anwarali1971
    @anwarali19712 жыл бұрын

    ager koi sensr garam pani main garam cool pani thanda hojai to woh sahe mana jai?

  • @MuhammedSabikqr
    @MuhammedSabikqr Жыл бұрын

    😮

  • @mohdadilkhan1488
    @mohdadilkhan14882 жыл бұрын

    Sir hamare window ac remot nhi chal rha sir display se karna pad rha hai sensor problems

  • @abdulraheemthebo8212
    @abdulraheemthebo82122 жыл бұрын

    Sir mery pas ek complain aya hey jis me compressor ampere barhatey jata tha or 20A pe ja k k trip kr jata phley jaldi trip krta tha phr capicitor change kiya to kuch der krney laga aj me ac workshop pe le k aya hon is me capillary 20 inch laga huwa or iska size screw guage 2.52mm hey iska ye data sahi hey ya capillary change kron

  • @AMRESH11TECH

    @AMRESH11TECH

    Жыл бұрын

    Same size capillary aur filter new lagayen

  • @sandiaarif4092
    @sandiaarif40922 жыл бұрын

    Sarji. Mein. Aapke. Sath.kam. karna.chatahu. kiya. Aap.muje..saudi.arab.bulaaege.

  • @milindkhobragade4771
    @milindkhobragade47712 жыл бұрын

    sir mera 1.5 ton inverter ac 2 mahine pahile liya tha, pani nahi banata, aur raat ko kam cooling deta hai ,din me accha chilled karta hai , par dusara ac pani banata hai kya problem hai

  • @SKTECHNICAL9565

    @SKTECHNICAL9565

    2 жыл бұрын

    Please Reply

  • @junaidmansoorijunaidmansoo193
    @junaidmansoorijunaidmansoo1932 жыл бұрын

    Inverter ac ke outdor ke senser ke check kare

  • @AMRESH11TECH

    @AMRESH11TECH

    2 жыл бұрын

    Ok

  • @letsbehealthy1287
    @letsbehealthy12872 жыл бұрын

    Aap apna mobile phone de hume ac repair karwana he

  • @anwarali1971
    @anwarali19712 жыл бұрын

    a

  • @1991junaid1991
    @1991junaid1991 Жыл бұрын

    Mera 1.5 ton hitachi dc inverter split ac h 32 temperature set krne par bhi lagatar 6 ampere load aa rha h or room bahut hi jyada cool ho rha h Company wale ne dono pcb aur Room censor bhi change kr diya h fir bhi koi fayda ni hua Sir meri preshani door kariye

Келесі