How I Diagnose a Bad TXV | 👉 Thermostatic Expansion Valve 🦊

Фильм және анимация

In this HVAC training video, I will describe how I diagnose a bad TXV. A thermostatic expansion valve meters the flow of refrigerant into the evaporator coil.
#thermostaticexpansionvalve #hvactrainingvideos
HERE IS THE LINK FOR THE FLOW CHART 👇⬇
1drv.ms/u/s!AnT17rJhe6DVg9Jjd...
If the thermal expansion valve is bad the evaporator coil freezing might happen, which would reduce airflow to the point where no more air would blow into the house. It can be frustrating not knowing what's going on with your TEV or thermal expansion valve as some people call it. If you don't know the symptoms of a bad TXV, you might end up just making things worse for the homeowner. If you need TXV troubleshooting tips, don't be shy. I can get you through this! Figuring out your subcool and superheat will help you diagnose a bad TXV. The metering device on an evaporator coil could be a fixed orifice or a TXV. So, good luck with this video and the TXV explained.
🦊Please visit our website @ www.foxfamilyhvac.com
👉If you'd like to book an appointment with Fox Family Heating and Air in Sacramento, El Dorado, or Placer County, CA book.housecallpro.com/book/Fo...
**********************************************************************************
Visit us on our social media pages:
FLOW CHART LINK:
📘 Facebook @ / foxfamilyheatingaircon...
👦 LinkedIn @ / greg-fox-46ab48110
💻 Twitter @ / foxfamilyhvac
👨‍🔧Please help our channel produce more quality content for those interested in our industry.
SUPPORT HVAC and the BLUE COLLAR TRADES!
/ foxfamily
00:00 Intro
1:16 What's happening inside the evaporator coil?
3:13 Before diagnosing a bad TXV, Check the basics
4:52 Superheat
5:42 Subcool
6:10 Communicating refrigerant pressures to each other
6:36 What can we tell when we check superheat and subcool?
7:08 It’s a Bad TXV. What Can I Do Now?

Пікірлер: 57

  • @khoolexairconditioning868
    @khoolexairconditioning8682 жыл бұрын

    This video is as good as it gets, very informational and to the point, thank you from Florida Greg.

  • @foxfamilyheatingandaircond4696

    @foxfamilyheatingandaircond4696

    2 жыл бұрын

    Awesome! Thanks!

  • @truthmatters6719

    @truthmatters6719

    Жыл бұрын

    ​@@foxfamilyheatingandaircond4696 great video sir! Just a quick question, if there's no liquid line service valve how do I measure superheat?

  • @bikerbobcat
    @bikerbobcat10 ай бұрын

    The way I was trained was to verify Airflow (filters, coils, fans, obstructions) then Electronics (motors, capacitors, controls) before ever putting gauges on. In 10yrs residential and light commercial I've found far more bad customers than bad TXVs. This is a great video, thank you.

  • @rickacton7540

    @rickacton7540

    Ай бұрын

    whats a "bad customer"

  • @smacleod69
    @smacleod69 Жыл бұрын

    Actually with the 2007 regulations. Systems did not get more efficient with txv's. Its was because the suface area on the evap and condensor coils got bigger to absorb and reject more heat and humidity. Goodman proved this while staying with a piston metering device.

  • @marcost9461

    @marcost9461

    23 күн бұрын

    Yes 100

  • @InsideOfMyOwnMind
    @InsideOfMyOwnMind2 жыл бұрын

    I had a TXV diagnosed some years ago and they asked me for a glass of ice water. At the time I didn't know it was for the diag process but learned a minute later. He correctly called for the TXV. And yes, the system did perform somewhat better while the part was on order. Thing is, I kept the system operating right on the knee between function and failure by resting it periodically when it began to faulter so when he got here it was a no brainer compared to what it might have been. In other words, I did not let the compressor go thermal but the temps/pressures were still off so he could see in a snap what was up. Thanks for another nice tight discussion.

  • @dnell6854
    @dnell6854 Жыл бұрын

    I like that temperature method,Thanks for sharing

  • @marconantel7735
    @marconantel77352 жыл бұрын

    I loled at the guy hammering the tire when you said tap on it with a tool

  • @michaelmaclachlan2152
    @michaelmaclachlan21522 жыл бұрын

    Great explanation! As a first year tech, I can't tell you how helpful this is to grasp the concepts of refrigeration. The illustrations we're especially helpful.

  • @foxfamilyheatingandaircond4696

    @foxfamilyheatingandaircond4696

    2 жыл бұрын

    Perfect!

  • @LuisLujan-xc7bd

    @LuisLujan-xc7bd

    10 ай бұрын

    Could you please share the illustrations? I'm having a hard time opening the link. I'm guessing it's no longer good

  • @jmead6121
    @jmead612111 ай бұрын

    Thanks great explanation of TXV operations ..30 yrs in & I take notes ..Tks again newbies will really Love the tutelage

  • @bikerbobcat

    @bikerbobcat

    10 ай бұрын

    Every day I learn something new.

  • @victorebolum1583
    @victorebolum158310 ай бұрын

    All your videos are thoroughly presented. A real teaching moment. Thank you.

  • @eulaliorodriguez5325
    @eulaliorodriguez53259 ай бұрын

    Thank you for sharing this video.

  • @watermanone7567
    @watermanone75672 жыл бұрын

    Excellent video and explanation. Thanks

  • @foxfamilyheatingandaircond4696

    @foxfamilyheatingandaircond4696

    2 жыл бұрын

    Awesome. Thanks!

  • @scottgodwin3422
    @scottgodwin3422 Жыл бұрын

    Great info thanks

  • @MsFishingdog
    @MsFishingdog9 ай бұрын

    Great video

  • @marchomeautorepairs
    @marchomeautorepairs Жыл бұрын

    Keep up the good work

  • @dysfunctionalgamingveteran7753
    @dysfunctionalgamingveteran77532 жыл бұрын

    I use the field piece smans. When talking to other techs about my pressures I always give them both pressures and temps

  • @InsideOfMyOwnMind

    @InsideOfMyOwnMind

    2 жыл бұрын

    That's great, and then if they ask you what refrigerant you're dealing with you just learned something about the tech you're talking to.😂🤣😋😎

  • @marybethshipley2969
    @marybethshipley2969 Жыл бұрын

    Thank you so much!

  • @hookedup9424
    @hookedup94242 жыл бұрын

    Good video

  • @michaelcostello6991
    @michaelcostello69912 жыл бұрын

    Thanks

  • @cannadaincowboy
    @cannadaincowboy2 жыл бұрын

    With a heat exchange unit also can you cycle from heat to cool to see if the valve frees up? Would this damage anything doing this when the ambient temperature is in the high 90,'s to low 100..?

  • @zproxiimiity7733
    @zproxiimiity77338 ай бұрын

    Great video. Where can I get the flow chart? The link is broken!

  • @jascam1
    @jascam1 Жыл бұрын

    Excellent video, my installer wants to replace my TXV for the second time ( replaced with a piston while txv was ordered) on a 2 year newly installed SEER 16 Goodman Heat Pump. My temp is set on 77 degree but runs for 25 min on and 5 min off to do the job, this doesn't sound right. I need a good A/C tech in SW Florida.

  • @anthonybernier9952

    @anthonybernier9952

    10 ай бұрын

    Are you near Pensacola Florida?

  • @hectordaniel30
    @hectordaniel30Ай бұрын

    My man

  • @petesingh292
    @petesingh2922 жыл бұрын

    Great video Greg, but to get flow chart for txv?

  • @foxfamilyheatingandaircond4696

    @foxfamilyheatingandaircond4696

    2 жыл бұрын

    The link is in the description down below

  • @mackman77095
    @mackman770959 ай бұрын

    what is the step where it is correct subcool but high superheat? I dont see it on a the chart.

  • @leomerino3906
    @leomerino390610 ай бұрын

    Anywhere of getting that chart

  • @saltrue1555
    @saltrue15559 ай бұрын

    Very good information. Thank you

  • @user-vo9ho4vd9h
    @user-vo9ho4vd9h10 ай бұрын

    Does anyone know where to find this flow chart on the video? I click on the link but it is expired

  • @allanbrito13
    @allanbrito132 жыл бұрын

    I had one intermittently making the compressor pull into a vacuum

  • @foxfamilyheatingandaircond4696

    @foxfamilyheatingandaircond4696

    2 жыл бұрын

    Yep. Sounds right

  • @carltonthomas4819
    @carltonthomas48192 жыл бұрын

    When looking for txv everyone says to look at evap core but on york they are in the heat pump. Should I use super heat or subcool? Thanks!

  • @robertcherry4971

    @robertcherry4971

    2 жыл бұрын

    There should be one TXV at the condenser and another TXV at the evaporator on a Heat pump.

  • @seek3n
    @seek3n10 ай бұрын

    Hello, why does every CARRIER i put in (litterally 10 outta 10). always have 18-20 superheat and low liquid line pressure. Even with 13 subcool. Each install i spend like 3 days checking back and stuff. And I follow manufacturer installation religiously.

  • @xincai951

    @xincai951

    6 ай бұрын

    Have you figured out why? Do you need to adjust the txv?

  • @seek3n

    @seek3n

    6 ай бұрын

    @xincai951 no. They dont come with adjustable txv. I have to over size the coil at least half ton or slow down the fan 😅

  • @ChrisHVACguy
    @ChrisHVACguy Жыл бұрын

    most of those checks should have been done before putting on the gauges, but very nice flow chart!

  • @josemartinez-jt6tw

    @josemartinez-jt6tw

    Жыл бұрын

    Definitely right bro

  • @urvesh0607
    @urvesh0607 Жыл бұрын

    From where we order TXV valve?

  • @foxfamilyheatingandaircond4696

    @foxfamilyheatingandaircond4696

    Жыл бұрын

    Look for your local hvac supply store

  • @zacharyreed45
    @zacharyreed452 жыл бұрын

    oat, iat, sst, lst, sh, sc. KZread makes the jokes with that flow chart. Tesp & use the dumb chart in the manufacturer install manual to (don't worry the installers chucked it in the trash for you) guesstimate your airflow.

  • @robertpalmatier2699
    @robertpalmatier26993 ай бұрын

    Txv

  • @scottgodwin3422
    @scottgodwin3422 Жыл бұрын

    Hreat

  • @robertpalmatier2699
    @robertpalmatier26994 ай бұрын

    Must be the txv

  • @UtwoBed
    @UtwoBed10 ай бұрын

    The link to the flow chart is dead.☹

  • @mariod850
    @mariod8502 жыл бұрын

    Great video

  • @thomasdanieltucker9257
    @thomasdanieltucker9257 Жыл бұрын

    Good video

Келесі