HOW DOES A VALVE INSERT WORK IN A HEATER? Thermostatic valve, orifice, orifice

Ғылым және технология

See how the valve insert (thermostatic valve) with pre-setting in the central heating radiator works. The insert plays a very important role in the radiator, because it allows you to block the water flow through the radiator or to precisely set the amount of water flowing through the radiator by means of a presetting.
It should be remembered that the initial setting should be adjusted by the designer of the installation according to the calculations of various data, e.g. radiator power, room volume, water flow rate in the installation, etc. Independent adjustments may only take place in own central heating installations, where the heating boiler, pipes, radiators are ours and we will not limit the heat to others, for example in a multi-family building, by our regulations.
It is worth remembering carefully, saving the previous setting on the valve, so that in the event of disrupting your installation, you can restore the presetting settings to the same as they were before.
Adjustment by means of a pre-setting in the insert allows you to set the heating power of the radiator so that the room does not overheat, but importantly, it allows you to hydraulically balance the entire central heating system, thanks to which hot water will flow even to the farthest radiator, thanks to which the last radiator will also heat efficiently .
Simply put, if we have 3 radiators from the heating boiler in one run, it is worth setting a lower setting on the first radiator from the boiler, e.g. 2-3, because the hottest water will flow to the radiator, so a higher setting may waste heat from the water in too much. The next radiator should be set e.g. to 3-4, and the last to 4 or 5.
Such a simple, non-computational explanation is supposed to help you understand what this encroachment is about.
The most important thing is to be able to distribute all the heat supplied by water to each radiator, so we have to "skim", i.e. reduce the consumption of hot water by the radiators closest to the boiler, so that all heat is distributed to all radiators, so that even and balanced hydraulically, heated, that is, the efficiency of each was at the required level ..
Lack of pre-regulation, i.e. setting the maximum flow or not using the valve insert, will cause the first radiator to heat very strongly, the second - less, and the third - very little.
In the past, instead of a thermostatic valve (valve insert), a limitation of the water flow on the ball valve supplying water to the radiator was used, i.e. the flow was set aside or a coin was inserted between the radiator's flare nut and the central heating installation branch (pipe). hot water supply. These methods were unreliable and often generated additional noise or a hum that was not very pleasant.
NOTE: If you live in a multi-family block and there is central heating in the building, you are not allowed to change the settings on the thermostatic valve or valve insert without the appropriate consent of the building administrator or technical department. Any repairs, adjustments or changes can only be made by the owner, who usually has his maintenance technician, technical department or service technician who knows the building, knows the central heating installation and knows how even the smallest change to one radiator can affect other radiators at neighbors.
It is safest to always call the service or central heating service company, if you are not sure, knowledge and experience in plumbing work. Regulations during the heating and winter season carry the risk that if you break something, you may be left without heating until it is repaired. Hence, during this period, limit all repairs and changes to the necessary minimum.
SUBSCRIBE TO THE FORUMS OF KNOWLEDGE ► bit.ly/2XSLq36 and click 🔔
👀 WATCH INSTAGRAM OF THE KNOWLEDGE FORUM ► bit.ly/3aqY3oC
🔴 PINTEREST ► bit.ly/2KlMHrk
🔵 FACEBOOK ► bit.ly/2RQXiOX
⭐️ TWITTER ► bit.ly/2wUQ8SN
💡 Write questions, comments, doubts, suggestions in the commentary below the film. 😀
❗️ Subscribe to the "ForumWiedzy" channel to not miss new videos 👀
🎥 Share this video with your friends on social media 👨‍👩‍👦‍👦
👊 Regards
#Heater #Tapping #Knocking #CentralHeating # Connection #House #Apartment #Heating #Installation #CO #Installer # Valve
Thermostatic valve
Heater
Central heating
Initial setting
hydraulic balancing
Radiator
Valve insert
Oventrop
Danfoss
Key
Setting
Crushing
Crisis

Пікірлер: 24

  • @ForumWiedzy
    @ForumWiedzy3 жыл бұрын

    Tu zobacz, jak zablokować zawór termostatyczny: kzread.info/dash/bejne/nKyN07tqes_Kcs4.html

  • @Umciu
    @Umciu6 ай бұрын

    Dzięki za film, mam taki sam zawór, a bez rozbierania nie miałbym pojęcia czy ten zawór się wykręca czy kręci się dookoła.

  • @barteklxbxnxkx6965
    @barteklxbxnxkx69653 жыл бұрын

    Jesteś moim bohaterem🤣🤣🤣🤣🤣dobrze że wytłumaczyłeś co to za magiczne coś jest w grzejniku🤣🤣🤣🤣🤣

  • @ForumWiedzy

    @ForumWiedzy

    3 жыл бұрын

    Super ;)

  • @CzwartyPancernySP1AB
    @CzwartyPancernySP1AB2 жыл бұрын

    dobrze wytłumaczone

  • @ForumWiedzy

    @ForumWiedzy

    Жыл бұрын

    😉👍

  • @mariuszanonimowy7166
    @mariuszanonimowy71663 жыл бұрын

    Mój ty bohaterze. Wczoraj zastanawiałem się co to jest w grzejniku 😂

  • @ForumWiedzy

    @ForumWiedzy

    3 жыл бұрын

    :)

  • @janosolajos1844

    @janosolajos1844

    Жыл бұрын

    99

  • @pablopablo5039
    @pablopablo5039 Жыл бұрын

    Stary żeliwny grzejnik był zakręcony przez cały sezon i grzeje tylko na 2 żeberkach u góry. Musze spróbować mu ustawić kryzowanie na 6 aktualnie jest na 1 bo może ten mały otworek się zapchał. odpowietrzanie nic nie daje leci woda. Dzięki tobie i temu filmikowi zrozumiałem jak działa to kryzowanie. Dzięki.

  • @basias3604
    @basias36043 жыл бұрын

    A czemu grzejnik nadal grzeje (mniej, tylko góra grzejnika) mimo iż głowica jest ustawiona na zero? Dociśnięcie trzpienia nic nie zmienia :(

  • @knur8549
    @knur85493 жыл бұрын

    Fajny filmik dzięki bardzo za pomoc 💪mam pytanie A jak każdy grzejnik jest zasilany osobno to można pierwszy nastaw ten w grzejniku daj na Maxa i tylko regulować termostarem

  • @ForumWiedzy

    @ForumWiedzy

    3 жыл бұрын

    Dziękuję za opinię. Pozdrawiam serdecznie

  • @Piontas
    @Piontas Жыл бұрын

    Jak dobrać głębokość wkładki zaworu ra-n pod grzejnik zasilany od dołu. Wkładki ra-n są różnej długości, proszę o informację co trzeba zmierzyć w grzejniku aby dobrać odpowiednią?

  • @Vader723
    @Vader7233 жыл бұрын

    Czy jak nastawiam grzejnik na np 2 a mam licznik a np na 5 to oszczędzam czy nie ???

  • @MrErox123
    @MrErox1233 жыл бұрын

    Mam problem, założyłem ostatnio zawór termostatyczny i jeśli ustawie na 4 bądź 5 to grzeje ale gdy ustawie na 2 bądź 3 tak jakby cały się zakręcał

  • @ForumWiedzy

    @ForumWiedzy

    3 жыл бұрын

    Jeśli jest to stary Zawór, może być zakamioniony. Ustaw go na najwyższy przepływ, niech się przepłucze przez godzinę. Dodatkowo rozruszaj go tak: kzread.info/dash/bejne/poNruKiBnc-6mbw.html

  • @00002mario
    @00002mario Жыл бұрын

    Są wkładki żeby był wiekszy otwór w środku żeby był lepszy przeplyw

  • @piotrdziki1403
    @piotrdziki14033 жыл бұрын

    A ja mam problem na 2 kaloryferach, przy wciśnięciu trzpienia tego zaworu max. do środka następuje takie stuknięcie. Z zamontowaną głowicą efekt jest taki że po jakimś czasie grzejnik zaczyna stukać z dużą częstotliwością i jest jak wibracja. praktycznie na każdym położeniu głowicy od 1-4 tylko na 0 nie grzeje i nie stuka i na 5 grzeje na max. czego nie chcemy. Co może być przyczyną, może uszkodzony grzybek zaworu i nieszczelność na uszczelce? Fachowcy już kryzowali, odpowietrzali, zamieniali głowice i dalej to samo od 2 lat :(

  • @ForumWiedzy

    @ForumWiedzy

    3 жыл бұрын

    Zobacz, czy to nie to ;) kzread.info/dash/bejne/gqNssrmwg5u5l8o.html

  • @mariannawarowski324

    @mariannawarowski324

    2 жыл бұрын

    miałem to samo , nie wiem jak to zrobił monter ale zasilanie pomylone było z powrotem ( grzejnik drabinkowy w łazience) zamieniłem to i jest OK

  • @gawelek1980
    @gawelek19802 жыл бұрын

    Nastawa wstepna ma 0 czyli zamknięcie całkowite?

  • @slawekh7862
    @slawekh78623 жыл бұрын

    a mnie brakuje tylko do szczęścia informacji po co ta wstępna regulacja jest a w zasadzie co ma powodować

  • @ForumWiedzy

    @ForumWiedzy

    3 жыл бұрын

    Nagram nowy film, ale zobacz póki co stary i pewnie wszystko zrozumiesz ;) kzread.info/dash/bejne/gq2JxM6blpmve9I.html