How a oil flooded rotary screw air compressor works

Ғылым және технология

Theory of operation

Пікірлер: 254

  • @rotarycomptech
    @rotarycomptech Жыл бұрын

    THE COMPRESSOR GURU IS A BIG FAT DUMB GOOF!!!!😢

  • @diezelkuchar6560

    @diezelkuchar6560

    11 ай бұрын

    What is the procedure for setting inlet valve clearance on a sullair that uses a diaphragm based control unit?

  • @rotarycomptech

    @rotarycomptech

    11 ай бұрын

    @@diezelkuchar6560 I obviously don’t know the machine that you’re working with, but it still remains the same if it is an analog machine or a PLC control machine. Get the machine to run unloaded adjust the linkage on the control arm and or the position of the butterfly inlet valve. You’re trying to get the compressor to maintain around 60 pounds of unloaded some pressure. And that’s basically it

  • @rotarycomptech

    @rotarycomptech

    11 ай бұрын

    @@diezelkuchar6560 One more thing if you’re working with a machine with a pressure switch typically an Allen, Bradley pressure switch is all you have to do to get the compressor to run on loaded is remove one of the wires from the pressure switch. Hopefully this helps.

  • @diezelkuchar6560

    @diezelkuchar6560

    11 ай бұрын

    @@rotarycomptech Thanks you for getting back to me this is very helpful.

  • @austinhancock2204

    @austinhancock2204

    10 ай бұрын

    Would you be able to do a service call over the phone/maybe face time? We have a diesel 750 sullair and a diesel 375 ingersoll rand I am trying to diagnose some issues on the air ends. Thanks in advance.

  • @BonEchoGearReviews
    @BonEchoGearReviews5 жыл бұрын

    I’m in the CNG industry but getting into high pres. Air compression. So much to learn. Thanks for the video

  • @outofcomms
    @outofcomms7 жыл бұрын

    Very informative video. I own a Sullivan Pallatek DF375 and it is the heart beat of my operation. If my compressor is not maintained regularly and given TLC it will let you know at the worst possible time, and for me that is not an option. Having purchased my Rig 5 months ago, I want to know as much as possible about every component that makes up compressor. Recently because of excessive oil in my Discharge, I removed the Sump separator element and did a close inspection, I was apprehensive at first having never done this, but with videos like yours and others, the task is not so intimidating. I took video as I proceeded and will post soon to help others. Pay it forward! Thank you, Joe DBTX

  • @tylerschwendeman6579

    @tylerschwendeman6579

    2 жыл бұрын

    My advice if your machine is an important element of your operation is to find a reputable air compressor distributed to look after your machines on a regular basis. It’s cheaper to maintain than to have breakdowns

  • @someguy9431
    @someguy94317 жыл бұрын

    Very cool. I'm a HVAC guy and seeing some of the similarities and differences with your type of compression was interesting.

  • @jessereiter328
    @jessereiter3288 жыл бұрын

    Thanks reminds of the time oil feild operations where turned over to me by my dad he would buy oil and gas wells plus the equipment and I would tune up all of the separators, compressers and dehydrators and keep them working he's gone now and I am retired but I sure enjoyed working like that some really cold winters and very hot summers.

  • @automaniacUSA
    @automaniacUSA8 жыл бұрын

    you're an awesome guy to answer all these questions. you've been great help. thank you for your videos and your time.

  • @NDC1115
    @NDC1115 Жыл бұрын

    I was a compressor tech for an Ingersoll-Rand distributor for 5 years. Couldn't of explained it better myself. I always liked working on Sullair units. They are simple, easy to service and tough as nails

  • @j3o5h8n5j5a3y8
    @j3o5h8n5j5a3y86 жыл бұрын

    Very nice video. I used to work on these in the 80's and for 30 years. Way back Sullair was using an auto transformer for start ups on the larger units ... like 400hp. I see the Sullicon inlet valve is gone. The rest looks the same except for the microprocessor controller. My last 10 years was with an IR company so I didn't get to see the Sullair version.

  • @saintsfan7991
    @saintsfan79916 жыл бұрын

    Hello, I just came across your channel while doing some compressor research and have thoroughly enjoyed your videos. They are extremely informative. I am about to purchase an early to mid 1990's LeRoi 185 cfm compressor with a John Deere diesel engine from a friend. I will be using it for soda blasting some restoration projects (mainly aluminum) that I have. I am not familiar with rotary compressors but look forward to learning more about their operation and the specific maintenance requirements of this LeRoi. My background is with Cat plunger/high pressure pumps, which seem like a piece of cake compared to these compressors. Thanks for uploading!

  • @ricturtle
    @ricturtle Жыл бұрын

    Thank you, I am a diesel mechanic by trade and have just got a job servicing and maintaining the screw compressors, really looking forward to it

  • @tdneVmo
    @tdneVmo9 жыл бұрын

    I was actually looking for a video where I could se people adjusting the VI and capacity, but this was good

  • @terryjaster4115
    @terryjaster41158 жыл бұрын

    I love the Sullair compressors. Or as we call it the big green machine. I use ours to supply air for ceco drop hammers. It works everyday hot cold it don't matter. It runs. ours doesn't have all the fancy electronics to it but I would put it up against any on any day. Thank you for this video.

  • @slamdvw
    @slamdvw11 жыл бұрын

    Thanks for the tour.

  • @morbeus1007
    @morbeus10077 жыл бұрын

    One word of caution when changing a separator element on a screw machine. If the seperator element flange has a gasket either side of it (some have O rings) make sure there is a way for the element to be electrically grounded. There`s usually a staple or foil strip to ground any static build up caused by the compressed air passing through the seperator. If the element isn`t grounded the static can build up and create a spark when it grounds itself. A spark mixed with oil vapour, heat and compressed air usually results in seperator vessel fire. It`s not so much a fire, more like an explosion; as it`s contained in the vessel. However the fire in the vessel will destroy the element with the result that debris will spread into the oil ways, the oil will be burnt, the safety valve will be damaged as will any controls fitted to the seperator vessel. Oh and you`ll need to visit the toilet as you will have crapped your self due to the massive band, flames and smoke. I`ve been a compressor engineer for nearly thirty years and this has happened twice; and that`s two times to many.

  • @layuptech

    @layuptech

    7 жыл бұрын

    noted did a oil separator change a couple weeks back I read the notice about checking ground but there was nothing about fire and smoke!

  • @abboudatieh193

    @abboudatieh193

    3 жыл бұрын

    Happened to me last year, so now i make sure all the staples in plus i run a ground wire from the tank (Receiver) cover (top) to the tank bottom then run a wire from there to the panel ground. I feel that’s safer

  • 4 жыл бұрын

    Thank your Video.I am woker repair air compressor.That video help me my job .

  • @josejuan61
    @josejuan612 жыл бұрын

    Very good explanation ! Thanks a lot !!!

  • @dingleburry7919
    @dingleburry79196 жыл бұрын

    Excellent video. Thanks.

  • @jamesstockbauer2119
    @jamesstockbauer21199 жыл бұрын

    Very helpful thank you very much for your time in doing this. I am in the gear industry

  • @KD0IDB
    @KD0IDB11 жыл бұрын

    Very intriguing! Good information.

  • @sithembisoduze8728
    @sithembisoduze87283 жыл бұрын

    This looks more like a VCC200S variable capacity but I didn't see the spiral valve assembly. Sullair is a reliable compressor brand if you service it correctly. Great video man!

  • @Aussie50
    @Aussie5011 жыл бұрын

    yer, the motor would pull a shitton of amps if it did suddenly try and reverse at speed! PS- what type of truck can i see in the background at the very start? never seen one here and it looks cool!

  • @enwri
    @enwri11 жыл бұрын

    was walking to the back of a hydraulic rockdrill, past the 4foot square oil cooler that blows out sideways just as the 2inch hose fitting blew off and emptied the separator into the fan, it wasn't hot enough to burn but it was still effing hot. would have made a good photo, one side drenched with oil, hair sticking out straight sideways, and I imagine a fairly surprised expression. it was an ingersol rand 350cfm behind a 3306 caterpillar with 4 big hydraulic pumps hanging off the front.

  • @Aussie50
    @Aussie5011 жыл бұрын

    Fantastic!, I wish I had this info when I was tearing into that 250Hp Champion unit!, and I wish I grabbed the air end to autopsy :(

  • @TheTinkr2
    @TheTinkr211 жыл бұрын

    Excellent job on the video, keep up the great work for all of us out here !!! With a 6 cyl air compressor (single stage) that puts out 100 psi per each cyl..Whats the maximum air pressure (psi) that I should get in the air tank at standard temperature ? Thanks

  • @wkweasel
    @wkweasel11 жыл бұрын

    I'm familiar with flooded screw compressors, we have a Sulair(s) where I work. I'm most interested in the method used for removing the oil from the air stream. As you stated some oil does go down stream but it must be a small amount. I suspect there must be a reduction in air velocity to allow the oil to drop out. I would like to know how this is done or directed to some information. I have a gas stream that needs to have most of the oil removed for proper operation and am looking for ideas

  • @survivor95
    @survivor9511 жыл бұрын

    upon shutdown the pressure is realsed from seperator tank , you can hear it through the silencer. at start up u get 6x amps so constant on off to evacuate fluid dury service severely strains motor. just 1 line end comes off. also there is available rotational alignment gauge to dial in air end to motor prior to coupler.

  • @Aussie50
    @Aussie5011 жыл бұрын

    that motor would make a beasty sound if it was wired wrong and went into reverse after starting!, those compressors starting sound awesome as they are!

  • @triggeral
    @triggeral6 жыл бұрын

    Love it!! Thank you for sharing!!

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    180-190f is normal discharge temp. The compressor must run @ a minimum temp of 170 f or you will make water/ condensate in the sump tank. Check the operation of the thermo valve AKA thermo mix valve, fluid diverting valve, thermostat

  • @cheerdiver
    @cheerdiver11 жыл бұрын

    What happens to the ambient air moisture? Does it make an emulsion w/ the oil. or separate?

  • @adriancorbato949
    @adriancorbato94910 жыл бұрын

    very intresting about sullair screw compresor. a model LS16-75

  • @rabahguemida3894
    @rabahguemida38949 жыл бұрын

    Hello I'm Chief Mechanic Rig please Show me more for flooded rotary screw air compressor works and How to be a maintenance process What is known at this type problems I liked it a lot and caught my attention Video Please you continue in this way to teach people Good luck

  • @workinprogress3942
    @workinprogress39422 жыл бұрын

    Yes sir. Excellent video.

  • @davidkierzkowski
    @davidkierzkowski11 жыл бұрын

    yeah really cool vid thanks for this

  • @rotarycomptech
    @rotarycomptech10 жыл бұрын

    I would check the contacts in the holding circuit like the stop switch, high temp switch, over load relay or relays, high pressure switch it's some switch in the circuit that is more than likely the cause

  • @ahmedsherif2527

    @ahmedsherif2527

    5 жыл бұрын

    Is the diagrams drawn in sullair manuals is the same as the real built compressors? because the blow down valve and solenoid valves symbols confusing me

  • @tdneVmo
    @tdneVmo9 жыл бұрын

    Thanks a lot!

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    Yeah you guys got some wild ass bugs in Australia!! Thanks for the comment!

  • @wkweasel
    @wkweasel11 жыл бұрын

    Not sure if a coalescing filter would work, It may plug up unless you can wash/flood them while in use. But then does that defeat the purpose?

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    Wow Iam not shure you could try a coalescing filter. Are you familiar with that type of filter?

  • @omararibi5808
    @omararibi58084 жыл бұрын

    Good video for training tank you

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    the air oil discharge temperature must be no lower than 175 degrees F or condensate will become an issue..to answer your question it is flashed off and is carried down the airline in the form of condensate

  • @Aussie50
    @Aussie5011 жыл бұрын

    its like a supercharger that uses oil to close the gap between the rotors to build higher pressures. you can't compress oil.

  • @jimmywang1722
    @jimmywang17226 жыл бұрын

    Well done one point that motor don’t care what rotation it goes ,just the screw will be affected I tell people check rotation check rotation check rotation and when your done check rotation ✌️

  • @ogrishtm
    @ogrishtm9 жыл бұрын

    Fantastic video, here's a question, where does the air go when it's being used and the pressure in the sump tank gets really high, is there a prv?

  • @rotarycomptech

    @rotarycomptech

    9 жыл бұрын

    It's vented from the sump tank by means of a blow down valve, if the blow down valve fails to operate there's a high pressure switch that shuts the machine down, if that fails to operate the sump tank pressure relief valve will lift and vent the sump tank

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    I'm well aware of how the blow down valve operates.when I preform the fluid change I disconnect the pilot line to the blow down valve then shut the air compressor off the sump tank remains pressurized and the fluid can be easily drained this practise eliminates the on off on off technique to evacuate the fluid. This is a C- flange motor arrangement. you can't change the alignment even if you wanted to

  • @davidbarrentine9631
    @davidbarrentine9631 Жыл бұрын

    Awesome video. I have 2 ingersoll rand sr100 at work and im trying to get them to run in sequence. Can you tell me how to do that. They both have Tellis controllers.

  • @rotarycomptech

    @rotarycomptech

    Жыл бұрын

    Hey David how’s it going? I R Intellis there were so many versions of that and I haven’t had that much experience with any type of sequencing of Ingersoll rand equipment you may have to go back to the distributor to get more information on that then I can give you, but if you know how to change the pressure switch settings you can always do that to select a lead machine. I used to do that with a couple of sullair machines do you keep the hours the same, I would just change the settings every 45 days or 1000 hours. Sorry I can’t help you anymore than that

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    First you need to dry the air does the current compressed air system have a compressed air dryer? There are basiclly two types refrigerated or desiccant

  • @lupo0144
    @lupo014411 жыл бұрын

    Hi....With a oil lubricated compressor (like shown) You'll pass oil and its in the low parts per million! Compressors uses a "Separator" filters..Some have screw on cans and some use a large "Top hat filler" in the top of the oil tank depending on model and make. The return line should be as hot as the oil tank when the compressor is loading. There are other tests like running the compressor in "Unload" and breaking the return pipe to see if you have vacuum and pressure each side of the brake

  • @Aussie50
    @Aussie5011 жыл бұрын

    haha thats cool!, yer it was a shame to scrap the big one but nobody wanted or needed it around my area. sadly it was too far gone electrically as I found out after opening the control panel and finding it full of water :( I would love to work in the compressor biz!, not sure who does it around my area tho.

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    Well my Australian friend if it wasn't for your video on that champion air compressor I would have never opened a youtube channel..I just had to make the comment why are you scrapping that thing!!? just for your information those air ends don't come apart easily. I still feel like this would be the perfect field for you to be in it's got everything electrical plumbing pneumatics refrigeration PLC control systems what more do you need? Thanks for commenting Ed

  • @Lotum4n
    @Lotum4n11 жыл бұрын

    Where is a pump system like this used ?

  • @mnairengineering1985
    @mnairengineering1985 Жыл бұрын

    Informative video

  • @clearboomer5060
    @clearboomer506010 жыл бұрын

    good day sir i had a DENYO MPS-55ss series air compressor the problem is that once i run it as it starts around a minute or two it stops .. can you give me an idea what causes this?.. thanks

  • @lanvr4
    @lanvr411 жыл бұрын

    Hi....What's the minimum temperature.. good for oil flooded compressor? I had some situation in tropical country.. The air end discharge temperature is @ 71 Celsius and injected coolant temperature @ 61 Celsius . I believed some wrong with this temperature..Could you share with us some experience.. Thanks.

  • @charlietanner6211
    @charlietanner62115 жыл бұрын

    sounds like rotary comp tech

  • @survivor95
    @survivor9511 жыл бұрын

    make sure seviceman removes blowdown tube before lube service. it'll save the new motor from excessive amps.

  • @ulisesdavidmoreno9058
    @ulisesdavidmoreno90583 жыл бұрын

    Awesome 🤩

  • @martyrehfeld8526
    @martyrehfeld85267 күн бұрын

    Whats fhe Best way to do a fluid change on these? Just changle filter, Drain sump and refill? Or is there a way to drain the system and refill? Cant seem to figure out what point to fill to. (I only drained the sump and refilled)

  • @rotarycomptech

    @rotarycomptech

    7 күн бұрын

    You’re better off to drain it under pressure, remove the quarter inch control line that goes to the blowdown valve then shut the machine down and it will maintain some pressure without blowing down

  • @montrose5paulina
    @montrose5paulina5 жыл бұрын

    Our compressor shuts off when the temperature starts to rise. It’s located outside. We are thinking about changing the heat coil too cool it off. What do you think will help from it shutting off besides the coil? We have a “LeRoi” brand.

  • @rotarycomptech

    @rotarycomptech

    5 жыл бұрын

    Hector Garcia-Martinez you can check the temperature going in and out of the cooler it should reject at least 30 degrees if it's more than that and it's still running hot you need to replace the thermo diverting valve element Also known as a thermostat. If you're not rejecting at least 30 degrees on the cooler than I would say replace the cooler.

  • @montrose5paulina

    @montrose5paulina

    5 жыл бұрын

    ROTARYCOMPTECH thank you for the reply and by the way, we are thinking about replacing the “heat exchanger” not coils.

  • @JorgeTorres-me9ym
    @JorgeTorres-me9ym4 жыл бұрын

    hi, you made this video very informative and understandable, i bought a 1992 EJBRDB 15HP , and it was converted from 460 to 230 , but i have been told it needs programing , because is plugged in but wont constan run. any advice will help. thank you

  • @rotarycomptech

    @rotarycomptech

    4 жыл бұрын

    I'm not familiar with that model number

  • @rotarycomptech

    @rotarycomptech

    4 жыл бұрын

    Sounds like a Gardner Denver model number

  • @jasonhill3133
    @jasonhill31336 жыл бұрын

    I have two sullair 2210's. It seems to me that their oil consumption is pretty high. Is their any way to adjust this or is it just the nature of the beast? Thanks for any help or advice on these machines.

  • @rotarycomptech

    @rotarycomptech

    6 жыл бұрын

    Jason Hill I would replace the separator element and make sure the scavenger line orifice and tubing it is as it should be

  • @jasonhill3133

    @jasonhill3133

    6 жыл бұрын

    ROTARYCOMPTECH thank you

  • @bobwhite3777
    @bobwhite37775 жыл бұрын

    Why would you have to bypass the oil cooler when it's on start up? Dose it pump better when it's hot?

  • @rotarycomptech

    @rotarycomptech

    5 жыл бұрын

    It's just the characteristics of the thermo diverting valve or thermostat like in your car, The thermostat element doesn't open up until it reaches its set temperature

  • @alanmartin729
    @alanmartin729 Жыл бұрын

    Ty informative video been going through he'll changing siezed compressor with a good used compressor that one sized in less than a minute called vanair tech not much help your video explains how the lube system works in detail afraid to change another compressor ty again

  • @wkweasel
    @wkweasel11 жыл бұрын

    I want to spray or mist an oil into a very low pressure dirty gas stream and then pull the oil back out collect the dirt and recycle. no refrig necessary. Need to clean up the gas so its usable. I thought of the flooded screw comp and thought the system of oil separation might work.

  • @JoseGomez-ml7zs
    @JoseGomez-ml7zs3 жыл бұрын

    Long shot but I have a sullair iso9001 and keep getting a starter fault. Any information you can give on what to look for would be appreciated. Thanks

  • @rotarycomptech

    @rotarycomptech

    3 жыл бұрын

    ISO 9001 Is a manufacturing standard not a model number

  • @JoseGomez-ml7zs

    @JoseGomez-ml7zs

    3 жыл бұрын

    @@rotarycomptech I see. The model is 3012 ac. I'm gonna read up on it

  • @churchillogarza2823
    @churchillogarza28239 ай бұрын

    muchas gracias tengo en mi trabajoun compresor igual, y gustaria conocerlo mucho mas ya que es a la par de la electrcidad el alma de la empresa

  • @bancroftricketts5678
    @bancroftricketts56789 жыл бұрын

    thanks very much for answer to me, can you tell me what torque you use for them, the book i have says for lid bolt 3/4 the torque is 200lb or 270 nm. so i think its too much.

  • @rotarycomptech

    @rotarycomptech

    9 жыл бұрын

    bancroft ricketts I've never used a torque wrench on the sump tank lid bolts, just tighten them good and tight your just trying to get the flange gaskets not to leak..Some times aftter running for a number of months it may be necessary to retorque the bolts

  • @joequilao5888
    @joequilao58887 жыл бұрын

    what major problem engine wont start

  • @PeterAwa
    @PeterAwa Жыл бұрын

    Where is the release pressure valve? Is it inbuilt into the screw compressor? Please advise.

  • @rotarycomptech

    @rotarycomptech

    Жыл бұрын

    The pressure relief valve is located on the side of the sump tank close to the lid

  • @automaniacUSA
    @automaniacUSA8 жыл бұрын

    I have an IR 185 cfm and I'm changing the separator element. the element fits horizontal in the tank. my question is, where should I position the brass hole that's on the face of the separator? should I align it with the savage line on the cover? that would be at the bottom or 6 o'clock position.

  • @rotarycomptech

    @rotarycomptech

    8 жыл бұрын

    +gettingitfirst Yep @ the bottom...That's an old unit they haven't used that style tank in a long time

  • @automaniacUSA

    @automaniacUSA

    8 жыл бұрын

    +ROTARYCOMPTECH. Yes it's a 1980 and still blowing strong. thanks for the quick reply

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    Did this video clear things up?

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    100 PSIG @ around 300 F

  • @willemstark4733
    @willemstark47337 жыл бұрын

    what is the best oil too use beside the screw compressor oil? that oil is pricey ass hell

  • @rotarycomptech

    @rotarycomptech

    7 жыл бұрын

    you can use a 10 or 20 weight hydraulic oil and change it every thousan hours .Running any other fluid besides the PAO or polyglycol compressor fluid will result in oil carry over and the possibility of forming varnish deposits in the interior of the compressor mainly the cooler itself

  • @willemstark4733

    @willemstark4733

    7 жыл бұрын

    +ROTARYCOMPTECH do you have any example what hydraulic oil? i know only 10w 40 and stuff like that about the viscosy

  • @rotarycomptech

    @rotarycomptech

    7 жыл бұрын

    there's a product that Sullair used to use called DA torque fluid, or the Mobil delvac products

  • @jonminnella2168
    @jonminnella21687 жыл бұрын

    y delta is a tricky stuff

  • @brijeshbhardwaj7792
    @brijeshbhardwaj77925 жыл бұрын

    In our plant have SA350 oil inject screw air compressor. In these have two oil filter after the oil cooler . So I want to know that all these two filter work continues at same time or one work at a time and one stand by. Please reply me.

  • @rotarycomptech

    @rotarycomptech

    5 жыл бұрын

    They work together with some what of the less passive resistance Theory but they're both needed as one isn't large enough more than likely

  • @januario111torreon2
    @januario111torreon27 жыл бұрын

    Is there any danger in danger in modifying the coupling. We were having problem with purchasing the parts. What we did was replacing it with fabricated sprocket and used chain to couple the compressor and motor. The unit seem to run normal but after few minutes it will shutdown. Is there kind of a knock sensor that make it stop when sensing abnormal changes in vibration? We where also having problem with unlocking key password of the user setting. The unit is DMC with 100 hp motor.

  • @rotarycomptech

    @rotarycomptech

    7 жыл бұрын

    there's no problem in modifying the drive coupling there is no vibration sensor on any of the rotary screw compressors that I've seen

  • @januario111torreon2

    @januario111torreon2

    7 жыл бұрын

    Thanks for making the video people like me learn something from it.

  • @farhanhakimul8053
    @farhanhakimul80532 жыл бұрын

    Excuse me , when unload solenoid valve is open or close ??

  • @rotarycomptech

    @rotarycomptech

    2 жыл бұрын

    It’s a normally open solenoid valve. Loss of power or shut down the compressor unloads

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    it's just standard 100 psig plant air

  • @BRENT3143945
    @BRENT31439456 жыл бұрын

    What kinda oil do you use? 30w?

  • @rotarycomptech

    @rotarycomptech

    6 жыл бұрын

    BRENT3143945 10 w to 20 w

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    180-190f is normal discharge temp

  • @CHRISINMCNEILL
    @CHRISINMCNEILL7 жыл бұрын

    I just picked up a Quincy QMT25 Quincy wants $475.00 for 5 gal of oil! Some local guys that have screws to sand blast tell me to use ATF. What oil do you recommend?

  • @rotarycomptech

    @rotarycomptech

    7 жыл бұрын

    I would stay away from automatic transmission fluid it has a carryover problem a cheap alternative would be da torque fluid or the delvac Mobil Oil Products

  • @otm646

    @otm646

    7 жыл бұрын

    James Bounds We ran motor oil in our sand blasting screw for a decade without issue.

  • @BradFLHT

    @BradFLHT

    6 жыл бұрын

    Oil depends on use of compressor. Sand blasting with a unit creates a very dirty environment. Synthetics are best for long life, The trick is to properly filter the inlet air. A standard air filter is NOT the answer, spend some money and get a multi-stage air inlet filter. Most oil filters are 15 or 20 micron rated. you would want an air inlet filter 15 or less micron. Synthetic oils give you long oil change intervals (8000) hrs. or annually, oil filter every (2000) hrs, oil analysis is also recommended (2000) hrs. Petroleum based oils are only good for (1000) hrs or 3 months with the probability of varnish build up internally. ATF fluids lost their compatibility years ago. Different manufacturers of ATF came out with a wide "flash point" range. ATF is a 15 wt. You may want to consider a 20 wt. hydraulic with "antiwear/antifoam" additives. Also petroleum based fluids MUST be held to a strict change interval. Remember for every 5 degrees over 200F the oils life is cut in half, synthetic or petroleum based. Like all mechanical equipment neglect is the most harmful thing to an air compressor.

  • @chadlevelle4297
    @chadlevelle42974 жыл бұрын

    I have one just like this one I have problems with over temperature I cant figure out any ideas

  • @rotarycomptech

    @rotarycomptech

    4 жыл бұрын

    I'm assuming the unit is air cooled. There are quite a few things that can cause a overheating problem, Assuming you have not varnished the inside of the oil cooler by running an Inferior type of lubricant, and you don't have a high temperature rise of crossed the air end, I would pressure wash the cooler and replace the thermal valve

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    Your welcome

  • @nutbuster969
    @nutbuster9698 жыл бұрын

    Can i use atf as an oil for the compressor?

  • @rotarycomptech

    @rotarycomptech

    8 жыл бұрын

    Yes you can but it doesn't work out so well in humid environments it has a tendency to carry over past the separator element

  • @rotarycomptech
    @rotarycomptech11 жыл бұрын

    never seen it happen but it is possible

  • @user-in6xr2ke5j
    @user-in6xr2ke5j2 жыл бұрын

    Hey, I have combrosaur a two-hour working and then it stop giving i1 High alarm.

  • @rotarycomptech

    @rotarycomptech

    2 жыл бұрын

    I'm not really sure what you're exactly referring to but it sounds like you might have a high temperature shut down situation

  • @justinp7020
    @justinp70205 жыл бұрын

    Hey i have a series 20 100-150 i have a couple questions how could I get a hold of u.

  • @rotarycomptech

    @rotarycomptech

    5 жыл бұрын

    Right here right now

  • @justinp7020

    @justinp7020

    5 жыл бұрын

    I will get back to you Tommorow

  • @sanymathew8172
    @sanymathew81726 жыл бұрын

    Hello, we got screw compressor from Compair brand, we are facing some problem in that; can anyone please guide us to rectify the problem. The minimum set pressure is 6.4bar and maximum is 8.6 bar; some time it is not re-loading the air once after stopping the compressor on its maximum set pressure.

  • @arjunshrestha1591
    @arjunshrestha15916 жыл бұрын

    Hello I have seen your videos it's really good And I need your favour i have sullair LS25S compressor . When we start the compressor it is running but some mint latter it is shutdown by showing sum pressure low or separator pressure high please give me feed back how to tackel the problem

  • @rotarycomptech

    @rotarycomptech

    6 жыл бұрын

    arjun shrestha more than likely you have an issue with the pressure transducers or transducer, you need to First confirm that you don't have a high separator differential pressure. install a pressure gauge on the line side and a pressure gauge on the sump side or a differential pressure gauge, if the separator differential pressure is under 15 PSID you have an issue with the transducers not reading correctly. at this point if you do not have new transducers they can be calibrated inside of the microprocessor, or you may try to swap transducers as one may be reading higher than the other one. is all it takes is one transducer to read 5 lb High and one to read 5 lb low and a 5 lb differential across the separator and you're going to get that fault

  • @arjunshrestha1591

    @arjunshrestha1591

    6 жыл бұрын

    ROTARYCOMPTECH Hi hope you are doing good And thanks you for responding actually i already change new pressure transducer but problem is same . Actually when we start the compressor sum pressures is rising and stedy and also it goes full load after that when compressor is going unload the sump pressure also goes down it should be stedy or less not a zero and its showing low sump pressure error then compressors shut down i have a some photo can I send to you directly. Please suggest us to tackel the problem th

  • @rotarycomptech

    @rotarycomptech

    6 жыл бұрын

    arjun shrestha from what I'm reading and understanding in your comment it sounds like the unloaded sump pressure is not set correctly, when the compressor unloads the sump pressure should be no less than 30 PSIG ideally 60 PSIG, have you checked the unloaded sump pressure ?

  • @deepakthestunner

    @deepakthestunner

    4 жыл бұрын

    M also service engineer from India

  • @robertlong9552
    @robertlong95522 жыл бұрын

    What's the oil pressure while unloaded on this compressor pal

  • @rotarycomptech

    @rotarycomptech

    2 жыл бұрын

    No problem pal real simple The oil pressure in any oil flooded screw air compressor is roughly the same as the wet side of the sump. Air pressure = oil pressure

  • @robertlong9552

    @robertlong9552

    2 жыл бұрын

    @@rotarycomptechah sweet

  • @jazzman1910
    @jazzman19107 жыл бұрын

    What is the orifice size on the oil size on the oil feed line? or how do I determine the orifice size on the oil feed line?

  • @rotarycomptech

    @rotarycomptech

    7 жыл бұрын

    are you referring to the scavenger line?

  • @jazzman1910

    @jazzman1910

    7 жыл бұрын

    The main 1" line from the oil reservoir to the compressor lobes. I have an older Sullair R D24 compressor used for vent gas system that doesn't have an oil pump but there's no orifice(may be missing an orifice, no maintenance records) on the main oil feed line to the lobes; the problem is I'm observing excess oil carryover on the main header, it seems we're over flooding the compressor. The separator elements was replaced and the lines purged, problem still exists.

  • @rotarycomptech

    @rotarycomptech

    7 жыл бұрын

    +Mike Obu I've never seen a sullair air compressor with an oil pump only the vacuum pumps have oil pumps on them, I think I would get a hold of sullair or try to find a manual on the machine to try to determine if it had an orifice, you could always experiment around with a ball valve or a gate valve and throttle back the flow. I'm sorry I can't help you any further than that it all comes down to GPM, horsepower and RPM

  • @enwri
    @enwri11 жыл бұрын

    Also used a 1100 cfm@150psi compressor with an airtrack drill, if you forgot to blow it down before shutting it down it would spin the old 6/71 detroit diesel backwards for a second or two after it stopped. would tell the boss that I was just blowing all the giant biting march flies off the radiator... those flies are tough, they would fly into, or be thrown onto,the radiator and stay there all day, then fly off when it stopped.

  • @williamrekow7513

    @williamrekow7513

    Жыл бұрын

    I just bought a LeRoi Detroit powered screw compressor, what can you tell me about start up procedure on these? Is there some method to unload the compressor during start/warm?

  • @enwri

    @enwri

    Жыл бұрын

    @@williamrekow7513 I'll correct my above comment here, the 6V71 was a 750cfm, the 1100 was a Cat I think, rarely used that one, can't remember. After checking the fluids, aircleaners and inspecting for rat holes chewed in rubber intake elbows, It would start unloaded but was still a little intimidating. While pumping the fuel pressure primer and holding down the oil pressure bypass, you had to also turn the key. Key and button were on the same panel but reaching the primer at the same time (It was a little tired) required getting uncomfortably close in there. First thing the engine did from a standstill, is instantly rev to about 2500rpm for a few seconds before coming back down to idle. It never got much warmup before you could load it, when it would rev again before loading up and dropping back to idle. From standing halfway up a mountain in the the quiet, cool dawn listening to birds and enjoying a view out to the Coral Sea, the sound of a v671 roaring to redline was a bit of a contrast. Then the drilling started...

  • @williamrekow7513

    @williamrekow7513

    Жыл бұрын

    @@enwri: ours is a 365 with a 4-71.

  • @enwri

    @enwri

    Жыл бұрын

    @@williamrekow7513 I imagine they do the same rev ya head off stone cold as well. You had to pull or push a little brass knob to load and unload it.

  • @williamrekow7513

    @williamrekow7513

    Жыл бұрын

    @@enwriI guess I'll look for a brass knob.

  • @okieduca8327
    @okieduca83276 жыл бұрын

    just wanna checking how screw air compressor engineers out there, i am from indonesia and also work in the same field as you

  • @deepakthestunner

    @deepakthestunner

    4 жыл бұрын

    M also service engineer

  • @brijeshbhardwaj7792
    @brijeshbhardwaj77925 жыл бұрын

    Why do we use flexible hose after oil cooler and airend

  • @rotarycomptech

    @rotarycomptech

    5 жыл бұрын

    Because the manufacturer Sullair is too cheap to use steel lines anymore

  • @bancroftricketts5678
    @bancroftricketts56789 жыл бұрын

    can you explain how to change separator element please . i'm not really agree with the torque the book say.

  • @rotarycomptech

    @rotarycomptech

    9 жыл бұрын

    bancroft ricketts Don't remove the staples and tighten the bolts evenly..If the gaskets leak retorque, also I put grease on the gasket surfaces

  • @OyeTurri

    @OyeTurri

    9 жыл бұрын

    ROTARYCOMPTECH Hi, I'm also going to replace an Air/Oil Separator on a 250 cfm Sullivan Rotary Screw Compressor. Actually, the reservoir, or sump tank, is pretty much like the one on your video, except that it's shorter, but looks the same diameter. So my question is, what are the staples on the gasket for? The element I bought, has 2 staples on the gasket and they don't seem like they are holding anything together, just the gasket.

  • @rotarycomptech

    @rotarycomptech

    9 жыл бұрын

    ***** Do not remove the staples As you pass air through the separator element it causes static electricity The staples ground the separator element and Reduce the risk of a sump tank fire

  • @OyeTurri

    @OyeTurri

    9 жыл бұрын

    ROTARYCOMPTECH Thank you! Great info!

  • @Importssuckass
    @Importssuckass10 жыл бұрын

    That's the biggest compressor I have ever seen do you know how many CFM'S it does? BTW. I really like your videos too.

  • @rotarycomptech

    @rotarycomptech

    10 жыл бұрын

    About 4.50 SCFM per HP This compressor is a 75 HP so around 340-350 ACFM

  • @Importssuckass

    @Importssuckass

    10 жыл бұрын

    Cool thx. Keep up the good video's!

  • @hamieh1
    @hamieh17 жыл бұрын

    Thanks for posting , how many m3/min ?

  • @rotarycomptech

    @rotarycomptech

    7 жыл бұрын

    I'm sorry Mohammad I don't understand the question

  • @hamieh1

    @hamieh1

    7 жыл бұрын

    +ROTARYCOMPTECH I meant the capacity volume output ? Thanks

  • @rotarycomptech

    @rotarycomptech

    7 жыл бұрын

    +Mohamad Khalil Hamieh the SCFM rating on rotary screw compressors of the single-stage version is about 4 CFM per horsepower. this 75 horsepower horsepower compressor it is rated at around 320 CFM

  • @hamieh1

    @hamieh1

    7 жыл бұрын

    +ROTARYCOMPTECH thank for the valuable information , thumbs up .

  • @deepakthestunner

    @deepakthestunner

    4 жыл бұрын

    How much an reciprocating air compressor deliver air as screw air compressor deliver 4cfm in 1 hp?

  • @survivor95
    @survivor9511 жыл бұрын

    i stumbled into your video as with youtube u never know what you watch sometime. it made me think hard, your vid. friggin brain injury. i was trained in michigin city indiana sullair plant.

  • @HectorRodriguez-sy9rt
    @HectorRodriguez-sy9rt2 жыл бұрын

    How can I drain the water

  • @rotarycomptech

    @rotarycomptech

    2 жыл бұрын

    from where?

  • @ruibem7051
    @ruibem70517 жыл бұрын

    Hi guy i own to v200s sullair compressor and cant seem to reset the dam mentenance service light. A ante in the book. I realy dont need to call sullaur. To rest a service. I know. Theyll charge. Me to reset. Service. Some of want to save do our self. Do you have any infor on this. I can only look threw the controls it. Wont let me chang any thing. Thank for your. Time.

  • @rotarycomptech

    @rotarycomptech

    7 жыл бұрын

    Rui Bem is that a portable compressor?

  • @ruibem7051

    @ruibem7051

    7 жыл бұрын

    ROTARYCOMPTECH Its oil flooded rotary twin screws igets some pic so yall can see there are not very old. 1 is bulit in 2015 and there other 2012. They both are Air cooled radiator fan Just like video Watch it all time. And i apply at wrk