No video

Gas Fireplace Won’t Turn On? Easy DIY Fix in Three Simple Steps for Homeowners

🔥 Having trouble getting your gas fireplace to turn on? No worries! In this video, I got you covered with a quick and easy guide for homeowners. Discover three straightforward steps to troubleshoot and fix the issue, so you can cozy up by the fire in no time.
🛠️ my step-by-step instructions will walk you through the common reasons why your gas fireplace might not be turning on and provide simple solutions that anyone can do at home. Whether you're a seasoned DIY enthusiast or a first-time homeowner. Save time and money by avoiding unnecessary service calls. Learn how to identify and resolve issues such as wall switch, pilot flame colour and adjust its size. With just a few minutes, you can bring warmth back into your home and enjoy the ambiance of a working gas fireplace.
Don't let a non-functioning fireplace intimidate you and dampen your winter vibes. Watch this video now and empower yourself with the knowledge to troubleshoot and fix your gas fireplace effortlessly. Hit that play button and let's get your home feeling warm and inviting again! 🔥🏡
Remember to like, share, and subscribe for more helpful tips on home maintenance! 🛠️✨
How to Clean Pilot Assembly on Gas Fireplace for Homeowner
• How to Clean the Pilot...
How to Light Pilot on Gas Fireplace
• How to Light the Pilot...
How to Remove Glass from Gas Fireplace within 2 Minutes
• How to Remove Glass fr...
take a look at my other appliance repair videos
Unclog Drain Pump: Whirlpool Duet Washing Machine Repair
• Unclog Drain Pump: Whi...
Washing Machine Drain Pump Test with Multi-meter
• Washing Machine Drain ...
Samsung Oven not Heating up Properly? Troubleshoot and DIY Heating Element Replacement Guide
• Samsung Oven won't Hea...
Whirlpool Dryer Won't Start - Troubleshooting and Finding the Faulty Part for Repair
studio.youtube...
How to Defrost Samsung Refrigerator in Force Defrost Mode DIY
• How to Defrost Samsung...
Samsung Fridge Too Cold, freezing food Fixed by Replacing Temperature Sensor DA32-00011C
• Samsung Refrigerator/F...
Samsung Fridge Water Leakage Problem How to Fix
• Fixing Samsung Refrige...
How to Remove Glass from Samsung Refrigerator Shelf within 4 Minutes
• How to Remove Samsung ...
Samsung Refrigerator Ice Buildup, Noisy Fan and Not Cooling, Fix All in One Repair
• Samsung Refrigerator/F...
00:00 Intro
00:26 First step verify switch or wire
03:33 Second step check pilot flame color
04:24 Third step check thermopile millivolt
07:22 Principle behind the three simple steps

Пікірлер: 24

  • @cpnurseries
    @cpnurseries3 ай бұрын

    The best video I have seen on this subject! Thank you for your clear and helpful commentary.

  • @guelphming3843

    @guelphming3843

    3 ай бұрын

    Thanks for your kind comment.

  • @dragoaus
    @dragoaus3 ай бұрын

    Thank you so much

  • @guelphming3843

    @guelphming3843

    3 ай бұрын

    Thanks for watching.

  • @cindyliu812
    @cindyliu8126 ай бұрын

    Super clear. Thank you so much! We were able to fix our fireplace!!

  • @guelphming3843

    @guelphming3843

    6 ай бұрын

    Glad it help and thank for nice comments

  • @Gg-mo5do
    @Gg-mo5do3 ай бұрын

    Hi - Thanks for the great video and diagram explaining how these systems work. I have followed the instructions, but the fireplace is still not lighting. I have 535 mv at the TP / TPTH terminals and have tried jumping these terminals with a paper clip. When jumped, there is no click from the gas valve opening. Do you have any suggestions for further troubleshooting or an idea what could be wrong? Thanks!

  • @xiaowenxu6199
    @xiaowenxu61997 ай бұрын

    Very detailed explanation!

  • @guelphming3843

    @guelphming3843

    7 ай бұрын

    Glad you think so!

  • @yingxing7181
    @yingxing71817 ай бұрын

    It’s very helpful for understanding the working mechanism for fireplace. Really appreciate it! If the pilot light goes off after releasing pilot button, does it mean the thermocouple is broken? Could you please explain a little more on the thermocouple circuitry?

  • @guelphming3843

    @guelphming3843

    7 ай бұрын

    Thanks for watching. There are a few to check 1. Check pilot flame colour, clean vacuum pilot if necessary. 2. Clean thermocouple 3. Check if thermocouple is surrounded by pilot flame you can either adjust position or turn pilot adjustment screw to increase the size of pilot. 4. Make sure gas valve open plus if you live in rural areas hold pilot knob for longer time to purge air in the gas line. Hope these can help. Good luck.

  • @guelphming3843

    @guelphming3843

    7 ай бұрын

    For cleaning pilot thermocouple take a look this video How to Clean Pilot Assembly on Gas Fireplace for Homeowner kzread.info/dash/bejne/aml_2bxyorrKo7g.html

  • @rajvyasmca
    @rajvyasmca7 ай бұрын

    Hi @GuelphMing, Your video is really a very helpful. Thanks for sharing with us. Can you please advise me what could be the reason behind My gas fireplace pilot and flame keep turning off after 2-3 min or sometime 5min-20min later. Thank you

  • @guelphming3843

    @guelphming3843

    7 ай бұрын

    Thank you for watching. Check the following things 1. Pilot flame colour, if not blue clean pilot assembly and orifice. 2. Check pilot flame size, If pilot flame too small turn it up by pilot adjustment screw. Also, ensure the pilot light is strong and steady; a weak flame might cause it to go out. 3. check if the thermocouple is positioned correctly in the flame. If it's not, it might shut off as a safety feature. 4.make sure the thermocouple is clean. Try these steps.

  • @rajvyasmca

    @rajvyasmca

    7 ай бұрын

    Thanks for your quick reply and I did all these steps but haven’t tried jumper to make it direct,, after couple of on and off it was stabbed but new problem power switch some time works some time not, it’s common for gas fireplace after setup from pilot to on mode, and blower any further suggestions much appreciated. Power switch works fine as i can see the light in adapter and blower also works fine only issue with gas flame on off through the switch as it works sometimes but not always. Thank you

  • @lucahu

    @lucahu

    7 ай бұрын

    @@rajvyasmca @guelphming3842 Do you think it might be something wrong with the gas valve? if using one multimeter to make sure thermopole works well, it will be better.

  • @rajvyasmca

    @rajvyasmca

    7 ай бұрын

    @@lucahu yeah initially i thought the same thing but now i can see pilot is working fine since yesterday. So not sure what abd where is issue in wiring why it’s working sometimes but not always.

  • @boyputik6112
    @boyputik61127 ай бұрын

    Hello Sir. Thanks again for your video. I followed your procedures and eventhough the switch and wire is good and im getting 435mv when pilot valve is hot.still my burner wont come on.the flame is solid blue.i just wanna ask whats my next step?thank you sir hope you will answer my question.

  • @guelphming3843

    @guelphming3843

    7 ай бұрын

    Thanks for watching. Have you used jumper between terminal TH and TP/TH? Since pilot flame and readout are okay.

  • @manfat7051
    @manfat705115 күн бұрын

    Hi, my gas fireplace turned on by itself unexpectedly several times already. What could be wrong? Thanks.

  • @guelphming3843

    @guelphming3843

    15 күн бұрын

    Check start switch and start circuit.good luck.

  • @manfat7051

    @manfat7051

    15 күн бұрын

    @@guelphming3843 thanks. do you mean the switch on the wall? thanks again.

  • @Gg-mo5do
    @Gg-mo5do3 ай бұрын

    Hi - Thanks for the great video and diagram explaining how these systems work. I have followed the instructions, but the fireplace is still not lighting. I have 535 mv at the TP / TPTH terminals and have tried jumping these terminals with a paper clip. When jumped, there is no click from the gas valve opening. Do you have any suggestions for further troubleshooting or an idea what could be wrong? Thanks!

  • @guelphming3843

    @guelphming3843

    3 ай бұрын

    Thanks for watching. First of all, two terminals at TP/TH and TH need to be jumped, if you don’t hear click when you jumper above two terminals. You can check gas valve coil by measuring its resistance. Its range is a couple of Ohms. Good luck.