G120 drive MOTOR ID RUN | Commissioning

Ғылым және технология

G120 drive MOTOR ID RUN | Commissioning

Пікірлер: 7

  • @XxZroSheNxX
    @XxZroSheNxX6 ай бұрын

    do a video of commissioning of the drive since 0, u must do a master parameters to 1 and restart , when u download from the sd card or profinet card more useful

  • @XxZroSheNxX

    @XxZroSheNxX

    6 ай бұрын

    u work with fives machines ?, me too and old fives drives , ( fives oto and elletre)

  • @ETKLP

    @ETKLP

    6 ай бұрын

    Yes

  • @ETKLP

    @ETKLP

    6 ай бұрын

    Little bit start

  • @ETKLP

    @ETKLP

    6 ай бұрын

    @XxZroSheNxX u know about how to commissioning baumuller motor with Resolver to opde v32 ac drive. I have face a problem with Resolver ltn 21-A05 not set with motor aurtune not done properly hence motor run with noise and jurk

  • @XxZroSheNxX

    @XxZroSheNxX

    6 ай бұрын

    @@ETKLP normally them use a external card for encoders to divide the signal to speed,the position signal normally goes direct to drive , do u have any alarm ?, maybe "a.9.1.h" , i on holidays, havnt documents, but if are equal of adv200 ( the drivers are from grefran manufacturer) the position signal normally goes direct to drive we have this issue one time, try to run without encoder to check motor ( one time we have motor bad and do the same ), take care baumuller motors sometimes have different encoder signals in different pin than the older baumuller, check regulation mode, normally to incremental flux vector ol ( sometimes be erased by drive) and watch out , this drive have 2 encoder in, one on the serial port and the other on screws if are a update of driver, normally fives have pre-fitted , not easy , one time we have 3 days technician of fives to fix the calibration of a new driver to the motor and chain i see u are introducing pipe manufacturing , thermatool and fives in u videos, if are a random fail, change motor+encoder , check parameters are loaded and saved